Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement

被引:2
|
作者
Vallabhaneni, Srilakshmi [1 ]
Matka, Marsel [1 ]
Modi, Vivek [1 ]
Carey, Matthew [2 ]
Sarnoski, Christopher [3 ]
Durkin, Raymond [3 ]
Olenchock, Stephen [4 ]
Razzaghi, Mehdi [5 ]
Shirani, Jamshid [1 ]
机构
[1] St Lukes Univ Hlth Network, Cardiol, Bethlehem, PA 18015 USA
[2] St Lukes Univ Hlth Network, Internal Med, Bethlehem, PA USA
[3] St Lukes Univ Hlth Network, Intervent Cardiol, Bethlehem, PA USA
[4] St Lukes Univ Hlth Network, Cardiac Surg, Bethlehem, PA USA
[5] Bloomsburg Univ Penn, Stat, Bloomsburg, PA 17815 USA
关键词
aortic stenosis; transcatheter aortic valve replacement; patient prosthesis mismatch; outcomes; edwards sapien valve; HIGH-RISK PATIENTS; CLINICAL IMPACT; STENOSIS; IMPLANTATION; PREDICTORS; SURVIVAL; OUTCOMES; TRIAL;
D O I
10.7759/cureus.18044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Severe patient prosthesis mismatch (sPPM) after surgical aortic valve replacement is associated with worse outcomes. Limited data exists on the impact of sPPM on outcomes after transcatheter aortic valve replacement (TAVR), especially regarding the newer generation valves. The aim of this study was to evaluate the incidence, determinants, and outcomes of sPPM in patients undergoing TAVR with Edwards SAPIEN XT (ES XT) and Edwards SAPIEN 3 (ES3) valves (Edwards Lifesciences, Irvine, CA, USA). Methods We retrospectively reviewed 366 patients who underwent TAVR with ES XT (n = 114) or ES3 (n = 252) valves between July 2012 and June 2018. sPPM was defined as indexed effective orifice area (iEOA) <0.65 cm(2)/m(2). Kaplan-Meier survival estimates were used to determine outcomes. Results Multivariate linear regression analysis was utilized to determine potential independent effects of PPM on outcomes. sPPM was present in 40 (11%) of the patients [8 (7%) ES XT and 32 (13%) ES3] and was associated with female sex, smaller left ventricular outflow tract (LVOT) diameter and aortic valve annular area, absence of prior coronary artery bypass graft (CABG) surgery, shorter height, higher body mass index, and smaller pre-TAVR valve area (all p < 0.05). Among those with ES3 valves, the incidence of sPPM was inversely proportional to the valve size (50%, 25%, 5% and 3% for 20-, 23-, 26- and 29mm valve sizes, respectively; p < 0.001). At a mean follow-up period of 3.5 +/- 1.5 years, there was no difference in all-cause mortality (22.5% vs. 25.6%, p = 0.89) or a composite endpoint of heart failure, arrhythmias, stroke, and myocardial infarction (30% vs. 34%, p = 0.24) in those with or without sPPM. Conclusion ES3 was associated with a higher incidence of sPPM, particularly with smaller valve sizes. However, the presence of sPPM as defined by iEOA was not an independent predictor of adverse outcomes in patients undergoing TAVR within an intermediate follow-up period.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Comparison of Edwards SAPIEN 3 versus SAPIEN XT in transfemoral transcatheter aortic valve implantation: Difference of valve selection in the real world
    Arai, Takahide
    Lefevre, Thierry
    Hovasse, Thomas
    Morice, Marie-Claude
    Garot, Philippe
    Benamer, Hakim
    Unterseeh, Thierry
    Hayashida, Kentaro
    Watanabe, Yusuke
    Bouvier, Erik
    Cormier, Bertrand
    Chevalier, Bernard
    JOURNAL OF CARDIOLOGY, 2017, 69 (3-4) : 565 - 569
  • [22] Standardized Methodology for Transfemoral Transcatheter Aortic Valve Replacement With the Edwards Sapien XT Valve Under Fluoroscopy Guidance
    Kasel, Albert M.
    Shivaraju, Anupama
    Schneider, Stephan
    Krapf, Stephan
    Oertel, Frank
    Burgdorf, Christof
    Ott, Ilka
    Sumer, Christian
    Kastrati, Adnan
    von Scheidt, Wolfgang
    Thilo, Christian
    JOURNAL OF INVASIVE CARDIOLOGY, 2014, 26 (09): : 451 - 461
  • [23] Transcatheter Aortic Valve Replacement Using the Edwards SAPIEN Transcatheter Heart Valves
    Huang, Pei-Hsiu
    Eisenhauer, Andrew C.
    CARDIOLOGY CLINICS, 2013, 31 (03) : 337 - +
  • [24] EARLY DISCHARGE AFTER TRANSFEMORAL TRANSCATHETER AORTIC VALVE IMPLANTATION WITH THE EDWARDS SAPIEN-XT OR SAPIEN-3 PROSTHESIS: A PROSPECTIVE ANALYSIS OF SAFETY AND FEASIBILITY
    Bizios, Anna
    Cellier, Guillaume
    Durand, Eric
    Tron, Christophe
    Bauer, Fabrice
    Cribier, G. Alain
    Glinel, Bastien
    Eltchaninoff, Helene
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 413 - 413
  • [25] Periprocedural and Short-Term Outcomes of Transfemoral Transcatheter Aortic Valve Implantation With the Sapien XT as Compared With the Edwards Sapien Valve
    Mussardo, Marco
    Latib, Azeem
    Chieffo, Alaide
    Godino, Cosmo
    Ielasi, Alfonso
    Cioni, Micaela
    Takagi, Kensuke
    Davidavicius, Giedrius
    Montorfano, Matteo
    Maisano, Francesco
    Carlino, Mauro
    Franco, Annalisa
    Covello, Remo D.
    Spagnolo, Pietro
    Grimaldi, Antonio
    Alfieri, Ottavio
    Colombo, Antonio
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (07) : 743 - 750
  • [26] Comparing the Procedural and Clinical Outcomes of Sapien XT and Sapien 3 Valves in Transcatheter Aortic Valve Replacement in Korean Patients
    Kook, Hyungdon
    Jang, Duck Hyun
    Yang, Kyung-Sook
    Joo, Hyung Joon
    Park, Jae Hyoung
    Hong, Soon Jun
    Lim, Do-Sun
    Choi, Seung-Hyuk
    Choi, Young Jin
    Chang, Kiyuk
    Yu, Cheol Woong
    KOREAN CIRCULATION JOURNAL, 2020, 50 (10) : 907 - 922
  • [27] Transcatheter Tricuspid Valve Replacement With the Edwards SAPIEN Valve
    Kenny, Damien
    Hijazi, Ziyad M.
    Walsh, Kevin P.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (02) : 267 - 270
  • [28] Low Incidence of Prosthesis-Patient Mismatch Following Extremely Small Transcatheter Aortic Valve Replacement with 20-mm Sapien 3
    Okajima, Kazue
    Komatsu, Ikki
    Seto, Todd B.
    INTERNATIONAL JOURNAL OF ANGIOLOGY, 2021, : 120 - 125
  • [29] Early Edwards SAPIEN Valve Degeneration After Transcatheter Aortic Valve Replacement
    Harbaoui, Brahim
    Courand, Pierre-Yves
    Schmitt, Zoe
    Farhat, Fadi
    Dauphin, Raphael
    Lantelme, Pierre
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (02) : 198 - 199
  • [30] Transcatheter Pulmonary Valve Replacement With the Sapien Prosthesis
    Shahanavaz, Shabana
    Zahn, Evan M.
    Levi, Daniel S.
    Aboulhousn, Jamil A.
    Hascoet, Sebastien
    Qureshi, Athar M.
    Porras, Diego
    Morgan, Gareth J.
    Heaton, Holly Bauser
    Martin, Mary Hunt
    Keeshan, Britton
    Asnes, Jeremy D.
    Kenny, Damien
    Ringewald, Jeremy M.
    Zablah, Jenny E.
    Ivy, Margaret
    Morray, Brian H.
    Torres, Alejandro J.
    Berman, Darren P.
    Gillespie, Matthew J.
    Chaszczewski, Kasey
    Zampi, Jeffrey D.
    Walsh, Kevin P.
    Julien, Plessis
    Goldstein, Bryan H.
    Sathanandam, Shyam K.
    Karsenty, Clement
    Balzer, David T.
    McElhinney, Doff B.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (24) : 2847 - 2858