Implantable Cardioverter-Defibrillator Shock after Stenting Across the Device Leads

被引:3
|
作者
Mehra, Sanjay [1 ]
Chelu, Mihail Gabriel [1 ,2 ]
机构
[1] Brody Sch Med, East Carolina Heart Inst, Dept Cardiovasc Sci, Greenville, NC 27834 USA
[2] Univ Utah, Sch Med, Div Electrophysiol, Salt Lake City, UT USA
来源
TEXAS HEART INSTITUTE JOURNAL | 2016年 / 43卷 / 01期
关键词
Cardiac pacing; artificial; death; sudden; cardiac/prevention; control; defibrillators; implantable/adverse effects; device removal/education; equipment failure; kidney failure; chronic/therapy; prosthesis implantation/adverse effects; stents/adverse effects; stress; psychological/etiology; treatment refusal;
D O I
10.14503/THIJ-14-4759
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 45-year-old man with nonischemic cardiomyopathy and end-stage renal disease had lived uneventfully with a cardiac resynchronization therapy defibrillator (CRT-D) for 5 years. Less than a month before presenting at our institution, he had undergone stenting of his partially occluded subclavian vein, to relieve stenosis of the ipsilateral arteriovenous fistula that was used for his hemodialysis. The CRT-D subsequently discharged. Device interrogation revealed that electrical noise originating from leads damaged by the stent had caused the inappropriate shock and intermittent electrical discharges thereafter. The patient was highly traumatized by these events and insisted upon device removal, which deprived him of a potentially life-saving intervention. He later had a cardiac arrest that resulted in sustained profound hypoxic ischemic encephalopathy with minimal neurologic recovery: his family placed him in a long-term care facility on ventilator support, with a tracheostomy and feeding tube. This situation might have been avoided through collaboration between the interventional radiologist and the electrophysiologist. To our knowledge, this is the first report of a patient with nonischemic cardiomyopathy and end-stage renal disease who presented with inappropriate defibrillator discharge caused by lead damage secondary to stenting across the leads.
引用
收藏
页码:88 / 90
页数:3
相关论文
共 50 条
  • [1] Extraction of endocardial implantable cardioverter-defibrillator leads
    Le Franc, P
    Klug, D
    Jarwe, M
    Lacroix, D
    Delfaut, P
    Kouakam, C
    Kacet, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (02): : 187 - 191
  • [2] Evaluation and management of patients after implantable cardioverter-defibrillator shock
    Gehi, Anil K.
    Mehta, Davendra
    Gomes, J. Anthony
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (23): : 2839 - 2847
  • [3] How to respond to an implantable cardioverter-defibrillator shock
    Sears, SF
    Shea, JB
    Conti, JB
    CIRCULATION, 2005, 111 (23) : E380 - E382
  • [4] Implantable Cardioverter-Defibrillator Shock: Appropriate or Inappropriate?
    Nault, Michael A.
    McIntyre, William F.
    Simpson, Christopher S.
    Redfearn, Damian P.
    Abdollah, Hoshiar
    Brennan, F. James
    Baranchuk, Adrian
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2010, 15 (02) : 181 - 183
  • [5] Implantable cardioverter-defibrillator: Another device to cover
    Verheyden, CN
    Grothaus, PC
    Lynch, DJ
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 97 (05) : 944 - 951
  • [6] Risk of Failure of Transvenous Implantable Cardioverter-Defibrillator Leads
    Borleffs, C. Jan Willem
    van Erven, Lieselot
    van Bommel, Rutger J.
    van der Velde, Enno T.
    van der Wall, Ernst E.
    Bax, Jeroen J.
    Rosendaal, Frits R.
    Schalij, Martin J.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (04): : 411 - 416
  • [7] Insulation Defects in Riata Implantable Cardioverter-defibrillator Leads
    Sato, Akinori
    Chinushi, Masaomi
    Iijima, Kenichi
    Izumi, Daisuke
    Furushima, Hiroshi
    INTERNAL MEDICINE, 2012, 51 (19) : 2689 - 2694
  • [8] Implantable Cardioverter-Defibrillator Leads Design, Diagnostics, and Management
    Swerdlow, Charles D.
    Ellenbogen, Kenneth A.
    CIRCULATION, 2013, 128 (18) : 2062 - 2071
  • [9] LAPAROSCOPIC PLACEMENT OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEADS IN SHEEP
    BIELEFELD, MR
    YANO, OJ
    CABRERIZA, SE
    TREAT, MR
    KIRBY, TJ
    SPOTNITZ, HM
    CIRCULATION, 1992, 86 (04) : 569 - 569
  • [10] Learning From Implantable Cardioverter-Defibrillator Leads in Children
    Rottman, Jeff