Implantable cardioverter-defibrillator: Another device to cover

被引:2
|
作者
Verheyden, CN
Grothaus, PC
Lynch, DJ
机构
[1] SCOTT & WHITE MEM HOSP & CLIN, TEMPLE, TX 76508 USA
[2] SCOTT SHERWOOD & BRINDLEY FDN, TEMPLE, TX USA
[3] TEXAS A&M UNIV, HLTH SCI CTR, TEMPLE, TX USA
[4] TEXAS A&M UNIV, COLL MED, TEMPLE, TX USA
关键词
D O I
10.1097/00006534-199604001-00009
中图分类号
R61 [外科手术学];
学科分类号
摘要
The implantable cardioverter-defibrillator is a mechanical device developed to manage patients with life-threatening arrhythmias when pharmacologic control has failed or produced unacceptable side effects. It is a significant amount of foreign material with a generator pack (volume 113 to 145 cc, weight 197 to 235 gm) and two or three leads and patches that are inserted into or placed on the heart. Although it has worked very well in preventing premature death, there have been complications associated with the device itself. The most significant of these has been exposure and/or infection. We present three patients who have experienced this problem. Improved coverage has been accomplished by burying the implant beneath the rectus abdominis muscle in situations where skin and subcutaneous tissue alone have proved inadequate. By dividing one or two tendinous inscriptions and the anterior limb of the internal oblique fascia, a musculofascial pocket is created to contain the generator and lead wires. This provided satisfactory coverage in two of our three patients. The single failure resulted from external trauma to the abdominal wall.
引用
收藏
页码:944 / 951
页数:8
相关论文
共 50 条
  • [1] The implantable cardioverter-defibrillator
    Raj, SR
    Sheldon, RS
    PROGRESS IN CARDIOVASCULAR DISEASES, 2001, 44 (03) : 169 - 194
  • [2] The implantable cardioverter-defibrillator
    Greene, HL
    CLINICAL CARDIOLOGY, 2000, 23 (05) : 315 - 326
  • [3] The implantable cardioverter-defibrillator
    Groh, WJ
    Foreman, LD
    Zipes, DP
    AMERICAN FAMILY PHYSICIAN, 1998, 57 (02) : 310 - 312
  • [4] IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - LIFESAVER OR A DEVICE LOOKING FOR A DISEASE
    ZIPES, DP
    CIRCULATION, 1994, 89 (06) : 2934 - 2936
  • [5] The effect of device advisories on implantable cardioverter-defibrillator therapy
    Amin M.S.
    Ellenbogen K.A.
    Current Cardiology Reports, 2010, 12 (5) : 361 - 366
  • [6] Benefits of the implantable cardioverter-defibrillator
    Epstein, Andrew E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (14) : 1122 - 1127
  • [7] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    DELUCA, SA
    GIRARD, M
    AMERICAN FAMILY PHYSICIAN, 1989, 39 (01) : 141 - 143
  • [8] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    MIROWSKI, M
    REID, PR
    MOWER, MM
    WATKINS, L
    PLATIA, EV
    GRIFFITH, LSC
    JUANTEGUY, JM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (03): : 534 - 540
  • [9] Implantable cardioverter-defibrillator shocks
    Raitt, Merritt H.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (14) : 1366 - 1368
  • [10] Development of the Implantable Cardioverter-Defibrillator
    Maron, Barry J.
    Estes, N. A. Mark
    Rowin, Ethan J.
    Maron, Martin S.
    Reynolds, Matthew R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (04) : 353 - 373