Implantable cardioverter-defibrillator: Another device to cover

被引:2
|
作者
Verheyden, CN
Grothaus, PC
Lynch, DJ
机构
[1] SCOTT & WHITE MEM HOSP & CLIN, TEMPLE, TX 76508 USA
[2] SCOTT SHERWOOD & BRINDLEY FDN, TEMPLE, TX USA
[3] TEXAS A&M UNIV, HLTH SCI CTR, TEMPLE, TX USA
[4] TEXAS A&M UNIV, COLL MED, TEMPLE, TX USA
关键词
D O I
10.1097/00006534-199604001-00009
中图分类号
R61 [外科手术学];
学科分类号
摘要
The implantable cardioverter-defibrillator is a mechanical device developed to manage patients with life-threatening arrhythmias when pharmacologic control has failed or produced unacceptable side effects. It is a significant amount of foreign material with a generator pack (volume 113 to 145 cc, weight 197 to 235 gm) and two or three leads and patches that are inserted into or placed on the heart. Although it has worked very well in preventing premature death, there have been complications associated with the device itself. The most significant of these has been exposure and/or infection. We present three patients who have experienced this problem. Improved coverage has been accomplished by burying the implant beneath the rectus abdominis muscle in situations where skin and subcutaneous tissue alone have proved inadequate. By dividing one or two tendinous inscriptions and the anterior limb of the internal oblique fascia, a musculofascial pocket is created to contain the generator and lead wires. This provided satisfactory coverage in two of our three patients. The single failure resulted from external trauma to the abdominal wall.
引用
收藏
页码:944 / 951
页数:8
相关论文
共 50 条
  • [41] A prophylactic implantable cardioverter-defibrillator? Discussion
    Bourke
    Brugada
    Crick
    Kuck
    Rosenqvist
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 : 133 - 133
  • [42] Aspergillus infection of implantable cardioverter-defibrillator
    Cook, RJ
    Orszulak, TA
    Nkomo, VT
    Shuford, JA
    Edwards, WD
    Ryu, JH
    MAYO CLINIC PROCEEDINGS, 2004, 79 (04) : 549 - 552
  • [43] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - REPLY
    GARTMAN, DM
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 102 (01): : 162 - 163
  • [44] Hypertrophic cardiomyopathy and the implantable cardioverter-defibrillator
    Manovel-Sanchez, Ana J.
    Pedrote-Martinez, Alonso
    Arana-Rueda, Eduardo
    de Tejada, Francisco Errazquin-Saenz
    REVISTA ESPANOLA DE CARDIOLOGIA, 2007, 60 (07): : 784 - 784
  • [45] Externalized biventricular implantable cardioverter-defibrillator
    Mendes, Sofia Lazaro
    Ferreira, Joana Moura
    Ramos, Domingos
    Pego, Mariano
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2016, 35 (04) : 241 - 242
  • [46] ADVANCES IN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR THERAPY
    RAITT, MH
    BARDY, GH
    CURRENT OPINION IN CARDIOLOGY, 1994, 9 (01) : 23 - 29
  • [47] The implantable cardioverter-defibrillator - Patient perspective
    Reiffel, JA
    Dizon, J
    CIRCULATION, 2002, 105 (09) : 1022 - 1024
  • [48] Impact of the implantable cardioverter-defibrillator on rehospitalizations
    Valenti, R
    Schlapfer, J
    Fromer, M
    Fischer, A
    Kappenberger, L
    EUROPEAN HEART JOURNAL, 1996, 17 (10) : 1565 - 1571
  • [49] An Entirely Subcutaneous Implantable Cardioverter-Defibrillator
    Kleijn, Sebastiaan
    van der Veldt, Astrid
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (16): : 1577 - 1577
  • [50] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - AN OVERVIEW
    MIROWSKI, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) : 461 - 466