Effects of acetabular abduction on cup wear rates in total hip arthroplasty

被引:112
|
作者
Del Schutte, H [1 ]
Lipman, AJ [1 ]
Bannar, SM [1 ]
Livermore, JT [1 ]
Ilstrup, D [1 ]
Morrey, BF [1 ]
机构
[1] Med Univ S Carolina, Dept Orthopaed Surg, Charleston, SC 29425 USA
来源
JOURNAL OF ARTHROPLASTY | 1998年 / 13卷 / 06期
关键词
hip arthroplasty; polyethylene wear rates; acetabular abduction;
D O I
10.1016/S0883-5403(98)80003-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was designed to determine the effect of acetabular abduction on the polyethylene wear rates of the acetabular component. The hypothesis of this study is that acetabular placement, in particular abduction, effects contact forces and therefore polyethylene wear. A total of 364 total hip arthroplasties that were performed between 1974 and 1976 were included in this study. The cemented all-polyethylene acetabular components were the same for each case and came from a single supplier. The polyethylene wear rates were calculated by measuring the shortest radius from the center of the prosthetic femoral head to a point on the outer surface of the acetabular cup. An immediate postoperative radiograph was compared with a follow-up radiograph at least 9.5 years later. A standardized radiograph was used to prevent differences due to magnification. The abduction or inclination of the acetabular cups was measured in all of the patients. The amount of acetabular cup abduction was measured relative to the ischial tuberosity line. The mean abduction was 44.1 degrees with a standard deviation of 9.2 degrees and a median of 44 degrees. The range of abduction was from 0 degrees to 85 degrees. This analysis failed to show a correlation between the amount of acetabular abduction and polyethylene wear rates (Pearson's correlation coefficient = 0.0679; P = .20). With a sample size of 364, there is over a 95% change (statistical power) of detecting an underlying true correlation between wear and abduction that is greater than or equal to 0.20. We were unable to demonstrate a difference in wear that would correlate with the differing degrees of abduction of the acetabular socket. We felt that the radiographic measurements of wear were quite accurate. This method of determining acetabular abduction has also been documented and supported in previous literature and has allowed us to accurately determine acetabular abduction. The results of our study demonstrate that within the normal ranges described by our study, polyethylene wear did not significantly increase with increased abduction of the acetabular component.
引用
收藏
页码:621 / 626
页数:6
相关论文
共 50 条
  • [41] The effects of polyethylene cup thickness on wear of total hip prostheses
    Oonishi, H
    Iwaki, H
    Kin, N
    Kushitani, S
    Murata, N
    Wakitani, S
    Imoto, K
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (08) : 475 - 478
  • [42] Complete acetabular cup revision versus isolated liner exchange for polyethylene wear and osteolysis without loosening in cementless total hip arthroplasty
    Kyoung Hwan Koh
    Young-Wan Moon
    Seung-Jae Lim
    Hyun Il Lee
    Jae Woo Shim
    Youn-Soo Park
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1591 - 1600
  • [43] Complete acetabular cup revision versus isolated liner exchange for polyethylene wear and osteolysis without loosening in cementless total hip arthroplasty
    Koh, Kyoung Hwan
    Moon, Young-Wan
    Lim, Seung-Jae
    Lee, Hyun Il
    Shim, Jae Woo
    Park, Youn-Soo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (11) : 1591 - 1600
  • [44] The effects of polyethylene cup thickness on wear of total hip prostheses
    H Oonishi
    H Iwaki
    N Kin
    S Kushitani
    N Murata
    S Wakitani
    K Imoto
    Journal of Materials Science: Materials in Medicine, 1998, 9 : 475 - 478
  • [45] Total hip arthroplasty for crowe type IV developmental dysplasia of the hip using a dual mobility acetabular cup
    Ukaj, Skender
    Krasniqi, Shaip
    Ukaj, Dren
    Dervishaj, Fatime
    Dyla, Dea
    Mucaj, Sefedin
    Tahirbegolli, Bernard
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [46] COMPUTED-TOMOGRAPHY MEASUREMENT OF ACETABULAR CUP ANTEVERSION AND RETROVERSION IN TOTAL HIP-ARTHROPLASTY
    MIAN, SW
    TRUCHLY, G
    PFLUM, FA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (276) : 206 - 209
  • [47] Can the use of an inclinometer improve acetabular cup inclination in total hip arthroplasty? A review of the literature
    van Duren, Bernard H.
    Royeca, Joseph M.
    Cunningham, Conor M.
    Lamb, Jonathan N.
    Brew, Chris J.
    Pandit, Hemant
    HIP INTERNATIONAL, 2021, 31 (05) : 609 - 617
  • [48] Is transverse acetabular ligament an anatomical landmark to reliably orient the cup in primary total hip arthroplasty?
    Viste, A.
    Chouteau, J.
    Testa, R.
    Cheze, L.
    Fessy, M. -H.
    Moyen, B.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (03) : 241 - 245
  • [49] Acetabular cup position and risk of dislocation in primary total hip arthroplasty A systematic review of the literature
    Seagrave, Kurt G.
    Troelsen, Anders
    Malchau, Henrik
    Husted, Henrik
    Gromov, Kirill
    ACTA ORTHOPAEDICA, 2017, 88 (01) : 10 - 17
  • [50] A new radiographic acetabular cup anteversion measurement method in total hip arthroplasty: a clinical study
    Saka, G.
    Altun, G.
    Burc, H.
    Aydogan, M.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (04): : 813 - 818