Effects of acetabular abduction on cup wear rates in total hip arthroplasty

被引:112
|
作者
Del Schutte, H [1 ]
Lipman, AJ [1 ]
Bannar, SM [1 ]
Livermore, JT [1 ]
Ilstrup, D [1 ]
Morrey, BF [1 ]
机构
[1] Med Univ S Carolina, Dept Orthopaed Surg, Charleston, SC 29425 USA
来源
JOURNAL OF ARTHROPLASTY | 1998年 / 13卷 / 06期
关键词
hip arthroplasty; polyethylene wear rates; acetabular abduction;
D O I
10.1016/S0883-5403(98)80003-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was designed to determine the effect of acetabular abduction on the polyethylene wear rates of the acetabular component. The hypothesis of this study is that acetabular placement, in particular abduction, effects contact forces and therefore polyethylene wear. A total of 364 total hip arthroplasties that were performed between 1974 and 1976 were included in this study. The cemented all-polyethylene acetabular components were the same for each case and came from a single supplier. The polyethylene wear rates were calculated by measuring the shortest radius from the center of the prosthetic femoral head to a point on the outer surface of the acetabular cup. An immediate postoperative radiograph was compared with a follow-up radiograph at least 9.5 years later. A standardized radiograph was used to prevent differences due to magnification. The abduction or inclination of the acetabular cups was measured in all of the patients. The amount of acetabular cup abduction was measured relative to the ischial tuberosity line. The mean abduction was 44.1 degrees with a standard deviation of 9.2 degrees and a median of 44 degrees. The range of abduction was from 0 degrees to 85 degrees. This analysis failed to show a correlation between the amount of acetabular abduction and polyethylene wear rates (Pearson's correlation coefficient = 0.0679; P = .20). With a sample size of 364, there is over a 95% change (statistical power) of detecting an underlying true correlation between wear and abduction that is greater than or equal to 0.20. We were unable to demonstrate a difference in wear that would correlate with the differing degrees of abduction of the acetabular socket. We felt that the radiographic measurements of wear were quite accurate. This method of determining acetabular abduction has also been documented and supported in previous literature and has allowed us to accurately determine acetabular abduction. The results of our study demonstrate that within the normal ranges described by our study, polyethylene wear did not significantly increase with increased abduction of the acetabular component.
引用
收藏
页码:621 / 626
页数:6
相关论文
共 50 条
  • [11] Research Synthesis of Recommended Acetabular Cup Orientations for Total Hip Arthroplasty
    Harrison, Claire L.
    Thomson, Avril I.
    Cutts, Steven
    Rowe, Philip J.
    Riches, Philip E.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (02): : 377 - 382
  • [12] Biomechanical Evaluation of Acetabular Cup Implantation in Cementless Total Hip Arthroplasty
    Margalit, Kate A.
    Hayashi, Kei
    Jackson, Josh
    Kim, Sun Young
    Garcia, Tanya C.
    Wiggans, K. Tomo
    Aiken, Sean
    Stover, Susan M.
    VETERINARY SURGERY, 2010, 39 (07) : 818 - 823
  • [13] Acetabular Cup Design Influences Deformational Response in Total Hip Arthroplasty
    Meding, John B.
    Small, Scott R.
    Jones, Mary E.
    Berend, Michael E.
    Ritter, Merrill A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (02) : 403 - 409
  • [14] ACETABULAR CUP-SITING DEVICE FOR TOTAL HIP-ARTHROPLASTY
    DOYLE, J
    MURRAY, P
    MAHONY, PO
    FARMER, M
    HOOPER, AC
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1989, 108 (05) : 317 - 321
  • [15] The influence of acetabular component position on wear in total hip arthroplasty
    Wan, Zhinian
    Boutary, Myriam
    Dorr, Lawrence D.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 51 - 56
  • [16] Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty
    Sochart, DH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (363) : 135 - 150
  • [17] Does Pelvic Orientation Influence Wear Measurement of the Acetabular Cup in Total Hip Arthroplasty-An Experimental Study
    Wu, Junzhe
    Taylor, Dominic
    Forst, Raimund
    Seehaus, Frank
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [18] A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty
    Aydogan M.
    Burç H.
    Saka G.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (6) : 897 - 903
  • [19] Novel Measure of Acetabular Cup Inclination and Anteversion During Total Hip Arthroplasty
    Walter, William L.
    Baker, Neri A.
    Marsden-Jones, Daniel
    Sadeghpour, Ameneh
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2022, 15 : 1 - 14
  • [20] Improving Acetabular Cup Orientation in Total Hip Arthroplasty by Using Smartphone Technology
    Meermans, Geert
    Kats, Jan Jaap
    JOURNAL OF ARTHROPLASTY, 2013, 28 (07): : 1246 - 1246