Effects of acetabular abduction on cup wear rates in total hip arthroplasty

被引:112
|
作者
Del Schutte, H [1 ]
Lipman, AJ [1 ]
Bannar, SM [1 ]
Livermore, JT [1 ]
Ilstrup, D [1 ]
Morrey, BF [1 ]
机构
[1] Med Univ S Carolina, Dept Orthopaed Surg, Charleston, SC 29425 USA
来源
JOURNAL OF ARTHROPLASTY | 1998年 / 13卷 / 06期
关键词
hip arthroplasty; polyethylene wear rates; acetabular abduction;
D O I
10.1016/S0883-5403(98)80003-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was designed to determine the effect of acetabular abduction on the polyethylene wear rates of the acetabular component. The hypothesis of this study is that acetabular placement, in particular abduction, effects contact forces and therefore polyethylene wear. A total of 364 total hip arthroplasties that were performed between 1974 and 1976 were included in this study. The cemented all-polyethylene acetabular components were the same for each case and came from a single supplier. The polyethylene wear rates were calculated by measuring the shortest radius from the center of the prosthetic femoral head to a point on the outer surface of the acetabular cup. An immediate postoperative radiograph was compared with a follow-up radiograph at least 9.5 years later. A standardized radiograph was used to prevent differences due to magnification. The abduction or inclination of the acetabular cups was measured in all of the patients. The amount of acetabular cup abduction was measured relative to the ischial tuberosity line. The mean abduction was 44.1 degrees with a standard deviation of 9.2 degrees and a median of 44 degrees. The range of abduction was from 0 degrees to 85 degrees. This analysis failed to show a correlation between the amount of acetabular abduction and polyethylene wear rates (Pearson's correlation coefficient = 0.0679; P = .20). With a sample size of 364, there is over a 95% change (statistical power) of detecting an underlying true correlation between wear and abduction that is greater than or equal to 0.20. We were unable to demonstrate a difference in wear that would correlate with the differing degrees of abduction of the acetabular socket. We felt that the radiographic measurements of wear were quite accurate. This method of determining acetabular abduction has also been documented and supported in previous literature and has allowed us to accurately determine acetabular abduction. The results of our study demonstrate that within the normal ranges described by our study, polyethylene wear did not significantly increase with increased abduction of the acetabular component.
引用
收藏
页码:621 / 626
页数:6
相关论文
共 50 条
  • [1] ACETABULAR CUP WEAR IN TOTAL HIP-ARTHROPLASTY
    RIMNAC, CM
    WILSON, PD
    FUCHS, MD
    WRIGHT, TM
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1988, 19 (03) : 631 - 636
  • [2] Acetabular cup size trends in total hip arthroplasty
    Mckenna, Daniel Patrick
    Price, Alex
    Mcaleese, Timothy
    Dahly, Darren
    Mckenna, Paul
    Cleary, May
    WORLD JOURNAL OF ORTHOPEDICS, 2024, 15 (01): : 39 - 44
  • [3] Should the acetabular cup be medialised in total hip arthroplasty?
    Bonnin, Michel P.
    Archbold, Pooler H. A.
    Basiglini, Luca
    Selmi, Tarik A.
    Beverland, David E.
    HIP INTERNATIONAL, 2011, 21 (04) : 428 - 435
  • [4] Cementless total hip arthroplasty with a threaded acetabular cup
    J. Fernández-González
    R. Canosa Sevillano
    C. García-Araujo
    International Orthopaedics, 1997, 21 : 327 - 331
  • [5] Cementless total hip arthroplasty with a threaded acetabular cup
    Fernandez-Gonzalez, J
    Sevillano, RC
    Garcia-Araujo, C
    INTERNATIONAL ORTHOPAEDICS, 1997, 21 (05) : 327 - 331
  • [6] The transverse acetabular ligament may be used to align the acetabular cup in total hip arthroplasty
    Pearce, C. J.
    Sexton, S. A.
    Davies, D. C.
    Khaleel, A.
    HIP INTERNATIONAL, 2008, 18 (01) : 7 - 10
  • [7] Effect of acetabular cup position and orientation in cemented total hip arthroplasty
    Hirakawa, K
    Mitsugi, N
    Koshino, T
    Saito, T
    Hirasawa, Y
    Kubo, T
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) : 135 - 142
  • [8] Precision of acetabular cup placement in robotic integrated total hip arthroplasty
    Elson, Leah
    Dounchis, Jon
    Illgen, Richard
    Marchand, Robert C.
    Padgett, Douglas E.
    Bragdon, Charles R.
    Malchau, Henrik
    HIP INTERNATIONAL, 2015, 25 (06) : 531 - 536
  • [9] Oblong Acetabular Cup, Type TC, for Revision Total Hip Arthroplasty
    Trc, T.
    Stastny, E.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2012, 79 (06) : 506 - 511
  • [10] Dual mobility acetabular cup for total hip arthroplasty: use with caution
    Vahedi, Hamed
    Makhdom, Asim M.
    Parvizi, Javad
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (03) : 237 - 243