Metal Artifact Reduction by Dual-Energy Computed Tomography Using Energetic Extrapolation A Systematically Optimized Protocol

被引:136
|
作者
Meinel, Felix G. [1 ]
Bischoff, Bernhard [1 ]
Zhang, Qiaowei [2 ]
Bamberg, Fabian [1 ]
Reiser, Maximilian F. [1 ]
Johnson, Thorsten R. C. [1 ]
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Dept Radiol, Hangzhou 310003, Zhejiang, Peoples R China
关键词
metal implants; metal artifacts; dual-energy CT; dual-source CT; energetic extrapolation; CONE-BEAM CT; BONE REMOVAL; RENAL MASSES; IN-VITRO; ANGIOGRAPHY; PROJECTIONS; MULTISLICE; EXPERIENCE; IMPLANTS;
D O I
10.1097/RLI.0b013e31824c86a3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Energetic extrapolation is a promising strategy to reduce metal artifacts in dual-source computed tomography (DSCT). We performed this study to systematically optimize image acquisition parameters for this approach in a hip phantom and assess its value in a clinical study. Materials and Methods: Titanium and steel hip prostheses were placed in a standard hip phantom and a water tank and scanned on a DSCT scanner. Tube spectra, tube current ratio, collimation, pitch, and rotation time were optimized in a stepwise process. Artifacts were quantified by measuring the standard deviation of the computed tomography density in a doughnut-shaped region of interest placed around the prosthesis. A total of 22 adult individuals with metallic implants referred for computed tomography for a musculoskeletal indication were scanned using the optimized protocol. Degree of artifacts and diagnostic image quality were rated visually (0-10) and maximum streak intensity was measured. Results: Sn140/100 kVp proved superior to Sn140/80 kVp. There was a benefit for increasing tube current ratio from 1:1 to 3:1, but not beyond, in favor of the Sn140 kVp spectrum. Artifacts were less severe for a collimation of 32 x 0.6 mm as compared with 40 x 0.6 mm. A pitch of 0.5 at a rotation time of 0.5 seconds per rotation was preferable to other combinations with comparable scanning times. In the clinical study, increasing the extrapolated photon energy from 64 to 120 keV decreased the severity of artifacts from 8.0 to 2.0 (P < 0.001) and decreased streak intensity from 871 to 153 HU (P < 0.001). The median diagnostic image quality rating improved from 2.5 to 8.0 (P < 0.001). The median energy level visually perceived as optimal for diagnostic evaluation was 113 keV (range, 100-130 keV). Conclusions: Sn140/100 kVp with a tube current ratio of 3:1, a collimation of 32 x 0.6 mm, and extrapolated energies of 105 to 120 keV are optimal parameters for a dedicated DSCT protocol that effectively reduces metal artifacts by energetic extrapolation. The protocol effectively reduces metal artifacts in all types of metal implants. The optimized reconstructions yielded relevant additional findings.
引用
收藏
页码:406 / 414
页数:9
相关论文
共 50 条
  • [11] Metal Artifact Reduction Computed Tomography of Arthroplasty Implants Effects of Combined Modeled Iterative Reconstruction and Dual-Energy Virtual Monoenergetic Extrapolation at Higher Photon Energies
    Khodarahmi, Iman
    Haroun, Reham R.
    Lee, Moses
    Fung, George S. K.
    Fuld, Matthew K.
    Schon, Lew C.
    Fishman, Elliot K.
    Fritz, Jan
    INVESTIGATIVE RADIOLOGY, 2018, 53 (12) : 728 - 735
  • [12] Dual-energy-based metal segmentation for metal artifact reduction in dental computed tomography
    Hegazy, Mohamed A. A.
    Eldib, Mohamed Elsayed
    Hernandez, Daniel
    Cho, Myung Hye
    Cho, Min Hyoung
    Lee, Soo Yeol
    MEDICAL PHYSICS, 2018, 45 (02) : 714 - 724
  • [13] Gout: Update on Dual-Energy Computed Tomography with Emphasis on Artifact Identification
    Garner, Hillary W.
    Wessell, Daniel E.
    CURRENT RHEUMATOLOGY REPORTS, 2018, 20 (12)
  • [14] Gout: Update on Dual-Energy Computed Tomography with Emphasis on Artifact Identification
    Hillary W. Garner
    Daniel E. Wessell
    Current Rheumatology Reports, 2018, 20
  • [15] Reduction of Metal Artifacts Caused by Titanium Peduncular Screws in the Spine by Means of Monoenergetic Images and the Metal Artifact Reduction Software in Dual-Energy Computed Tomography
    Ceccarelli, Luca
    Vara, Giulio
    Ponti, Federico
    Miceli, Marco
    Golfieri, Rita
    Facchini, Giancarlo
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (02) : 152 - 158
  • [16] How Well Does Dual-Energy Computed Tomography With Metal Artifact Reduction Software Improve Image Quality and Quantify Computed Tomography Number and Iodine Concentration?
    Ohira, Shingo
    Kanayama, Naoyuki
    Wada, Kentaro
    Karino, Tsukasa
    Nitta, Yuya
    Ueda, Yoshihiro
    Miyazaki, Masayoshi
    Koizumi, Masahiko
    Teshima, Teruki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (04) : 655 - 660
  • [17] Metal Artifact Reduction by Using Dual-Energy Raw Data Constraint Learning
    Kong, Fanning
    Cheng, Ming
    Wang, Ning
    Cao, Huaisheng
    Shi, Zaifeng
    2021 14TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2021), 2021,
  • [18] Quantifying near metal visibility using dual energy computed tomography and iterative metal artifact reduction in a fracture phantom
    Hakvoort, E. T.
    Wellenberg, R. H. H.
    Streekstra, G. J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 9 - 18
  • [19] Periprosthetic Artifact Reduction Using Virtual Monochromatic Imaging Derived From Gemstone Dual-Energy Computed Tomography and Dedicated Software
    Reynoso, Exequiel
    Capunay, Carlos
    Rasumoff, Alejandro
    Vallejos, Javier
    Carpio, Jimena
    Lago, Karen
    Carrascosa, Patricia
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (04) : 649 - 657
  • [20] Quantification of Metal Artifact Reduction of Dual-Energy CT: A Phantom Study
    Li, K.
    Leung, W.
    MEDICAL PHYSICS, 2017, 44 (06) : 3036 - 3036