The uncertainties induced by internal pipe wall roughness on the measurements of clamp-on ultrasonic flow meters

被引:0
|
作者
Gu, Xiaotang [1 ]
Cegla, Frederic [1 ]
机构
[1] Imperial Coll London, Dept Mech Engn, South Kensington Campus, London SW7 2AZ, England
来源
2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2019年
关键词
Flow measurements; ultrasound; clamp-on flow meters; roughness; FLOWMETERS; SIMULATION;
D O I
10.1109/ultsym.2019.8926062
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Clamp-on ultrasonic flow meters (UFMs) have lower accuracy compared with spool piece UFMs because of the uncertainties introduced during the in-field installation process. Internal pipe wall roughness, one of these uncertainties, distorts the flow profile and causes the scattering of ultrasound. The objective of this paper is to carry out a parametric study to quantify the effect of scattering of ultrasound on the uncertainties of clamp-on UFM measurements without considering the flow disturbances. 2D finite element analysis was used to simulate the upstream and downstream signals of the clamp-on UFM based on some simplifying assumptions which were made about the effect of the flow. This simulation method was then verified by experiments which measure the uncertainties relating to the placement of ultrasonic probes at different separation distances. The simulation and experimental results were in good agreement. Then we applied this verified simulation method to investigate the uncertainties caused by the internal pipe wall roughness on the flow measurements. For ultrasonic waves at a frequency of 1 MHz and corroded internal pipe wall surfaces (0.2 mm RMS) it was found that systematic errors of 2 percent can result from the roughness induced scattering. This is a significant part of the measurement uncertainty range (1-5 percent) that is often quoted by manufacturers of clamp-on UFMs. This study therefore demonstrates that the accuracy of the clamp-on UFMs can be limited by the effects of internal pipe wall roughness.
引用
收藏
页码:1586 / 1589
页数:4
相关论文
共 50 条
  • [21] Clamp-On Measurements of Fluid Flow in Small-Diameter Metal Pipes Using Ultrasonic Guided Waves
    Dixon, Steve
    Li, Zhichao
    Baker, Matt
    Bushi, Xhorxh
    Smith, Luke
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70 (70) : 1 - 3
  • [22] High-temperature flow measurement with wetted and clamp-on ultrasonic sensors
    Lynnworth, Larry
    Sensors (Peterborough, NH), 1999, 16 (10): : 40 - 42
  • [23] Effect of incident angle on ultrasonic transmission in steam flow for use with clamp-on ultrasonic flowmeter
    Murakawa, Hideki
    Ichimura, Shuhei
    Shimada, Masaki
    Sugimoto, Katsumi
    Asano, Hitoshi
    Umezawa, Shuichi
    Sugita, Katsuhiko
    MECHANICAL ENGINEERING JOURNAL, 2020, 7 (04):
  • [24] Studies on the transducers of Clamp-on Transit-time Ultrasonic Flow meter
    Han, Jianping
    Liu, Hao
    Zhou, Yuanyuan
    Zhang, Rumei
    Li, Changji
    2014 4TH IEEE INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND TECHNOLOGY (ICIST), 2014, : 180 - 183
  • [25] 300 degrees C clamp-on ultrasonic transducers for measuring water flow and level
    Lynnworth, LC
    Jossinet, G
    Cherifi, E
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 407 - 412
  • [26] Liquid Flow Measurement Using Silicone Polymer Wedge Clamp-On Ultrasonic Transducers
    Li, Zhichao
    Hughes, Foz
    Kerr, Noel C.
    Wilson, Richard
    Dixon, Steve
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (07) : 5157 - 5165
  • [27] Flow disturbance compensation calculated with flow simulations for ultrasonic clamp-on flowmeters with optimized path arrangement
    Papathanasiou, Panagiotis
    Kissling, Beat
    Berberig, Oliver
    Kumar, Vivek
    Rohner, Adrian
    Bezdek, Michal
    FLOW MEASUREMENT AND INSTRUMENTATION, 2022, 85
  • [28] Measurement of steam flow rates using a clamp-on ultrasonic flowmeter with various wetness fractions
    Murakawa, Hideki
    Ichimura, Shuhei
    Sugimoto, Katsumi
    Asano, Hitoshi
    Umezawa, Shuichi
    Taira, Hirotoshi
    Ibi, Masayuki
    Akahane, Hajime
    FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 80
  • [29] Error Characteristics of Clamp-on Ultrasonic Flowmeters Depending on Location of Sensors and Downstream Straight Run of Bent Pipe
    Lee, Dong Keun
    Cho, Yong
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2011, 35 (08) : 861 - 868
  • [30] Influence of Flow Disturbances behind the 90° Bend on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines
    Synowiec, Piotr
    Andruszkiewicz, Artur
    Wedrychowicz, Wieslaw
    Piechota, Piotr
    Wroblewska, Elzbieta