The uncertainties induced by internal pipe wall roughness on the measurements of clamp-on ultrasonic flow meters

被引:0
|
作者
Gu, Xiaotang [1 ]
Cegla, Frederic [1 ]
机构
[1] Imperial Coll London, Dept Mech Engn, South Kensington Campus, London SW7 2AZ, England
来源
2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2019年
关键词
Flow measurements; ultrasound; clamp-on flow meters; roughness; FLOWMETERS; SIMULATION;
D O I
10.1109/ultsym.2019.8926062
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Clamp-on ultrasonic flow meters (UFMs) have lower accuracy compared with spool piece UFMs because of the uncertainties introduced during the in-field installation process. Internal pipe wall roughness, one of these uncertainties, distorts the flow profile and causes the scattering of ultrasound. The objective of this paper is to carry out a parametric study to quantify the effect of scattering of ultrasound on the uncertainties of clamp-on UFM measurements without considering the flow disturbances. 2D finite element analysis was used to simulate the upstream and downstream signals of the clamp-on UFM based on some simplifying assumptions which were made about the effect of the flow. This simulation method was then verified by experiments which measure the uncertainties relating to the placement of ultrasonic probes at different separation distances. The simulation and experimental results were in good agreement. Then we applied this verified simulation method to investigate the uncertainties caused by the internal pipe wall roughness on the flow measurements. For ultrasonic waves at a frequency of 1 MHz and corroded internal pipe wall surfaces (0.2 mm RMS) it was found that systematic errors of 2 percent can result from the roughness induced scattering. This is a significant part of the measurement uncertainty range (1-5 percent) that is often quoted by manufacturers of clamp-on UFMs. This study therefore demonstrates that the accuracy of the clamp-on UFMs can be limited by the effects of internal pipe wall roughness.
引用
收藏
页码:1586 / 1589
页数:4
相关论文
共 50 条
  • [41] Investigation of the wall friction in the pipe induced by the oscillating flow
    Jia, J. H.
    Du, J. Y.
    Wang, Y.
    Hua, H. X.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2008, 222 (03) : 387 - 392
  • [42] Ultrasonic Doppler flowmeter for low velocity pipe-flow measurements
    Luo, SN
    Liu, Y
    Feng, GP
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 1, 2004, : 638 - 642
  • [43] New developments in surface roughness measurements, characterization, and modeling fluid flow in pipe
    Farshad, F
    Rieke, H
    Garber, J
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2001, 29 (02) : 139 - 150
  • [44] The effect of roughness of the inner surface of the pipeline on the error of measurements using immersed vortex flow meters
    V. N. Volynkin
    M. S. Lur’e
    É. M. Sheinin
    Measurement Techniques, 2006, 49 : 158 - 162
  • [45] The effect of roughness of the inner surface of the pipeline on the error of measurements using immersed vortex flow meters
    Volynkin, VN
    Lur'e, MS
    Sheinin, EM
    MEASUREMENT TECHNIQUES, 2006, 49 (02) : 158 - 162
  • [46] Theoretical study of elastic effect of a cylindrical pipe wall on ultrasonic flow measurement
    Sun, Yanbing
    Zheng, Congren
    Zhang, Fanyong
    Tan, Xiaodong
    Chen, Kai
    Song, Xin
    Zhang, Xiang
    Chen, Yong
    MEASUREMENT, 2023, 219
  • [47] LDA measurements in the near-wall region of a turbulent pipe flow
    Universitaet Erlangen-Nuernberg, Erlangen, Germany
    J Fluid Mech, (305-335):
  • [48] MEASUREMENTS OF PRESSURES ON RIGID PIPE WALL DUE TO TURBULENT AIR FLOW
    DEMETZ, FC
    DEVIN, C
    JORGENSEN, DW
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1964, 36 (05): : 1044 - &
  • [49] Visualization and PIV measurements of the near wall structure in a turbulent pipe flow
    Zhang, ZS
    Feng, BC
    Cui, GX
    Ayrault, M
    ADVANCES IN TURBULENCE VIII, 2000, : 333 - 336
  • [50] Towards the validation of ultrasonic flowmeters operating in hydrogen-enriched natural gas mixtures through speed of sound measurements obtained by a clamp-on meter
    Cavuoto, G.
    Romeo, R.
    Lago, S.
    Albo, P. A. Giuliano
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 105 : 1178 - 1185