Metal Neck and Liner Impingement in Ceramic Bearing Total Hip Arthroplasty

被引:21
|
作者
Lee, Young-Kyun [1 ]
Yoo, Jeong Loon [1 ]
Koo, Kyung-Hoi [1 ]
Yoon, Kang Sup [1 ]
Kim, Hee Jong [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Orthopaed Surg, Seoul, South Korea
关键词
total hip arthroplasty; impingement; ceramic liner; microcrack; failure; ACETABULAR COMPONENTS; EARLY OSTEOLYSIS; REPLACEMENT; HEAD; POLYETHYLENE; FRACTURE; WEAR; PROSTHESIS; STABILITY; SIMULATOR;
D O I
10.1002/jor.21246
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although impingement between the neck of the metallic stem and the ceramic liner has been suspected to be the cause of ceramic liner failure in ceramic-on-ceramic total hip arthroplasty (THA), no report has directly demonstrated microscopic damage on ceramic liner. We performed 18 reoperations on 18 patients who had undergone third generation ceramic-on-ceramic THA. Considering impingement, 16 patients, who were reoperated more than 1 year after previous ceramic bearing THA, were evaluated. Retrieved alumina liners, showing evidence of impingement, were examined by means of visual inspection and scanning electron microscopy (SEM). Four of the 16 hips showed neck notching and black stained liners, evidence of metallic neck to ceramic impingement. Impinged alumina bearings had been implanted for an average of 62.5 months (range: 35-99 months) before reoperation. SEM of the black stained area demonstrated disruptive wear and loss of surface integrity. Furthermore, one liner had multiple microcracks, and its cross-sectional SEM analysis revealed one microcrack propagating into the deep portion of the ceramic liner. Our observations suggest that metal neck-to-ceramic impingement in ceramic-on-ceramic THA can cause microcrack formation in ceramic liner. (C) 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 29:218-222, 2011
引用
收藏
页码:218 / 222
页数:5
相关论文
共 50 条
  • [1] Impingement Between the Metal Stem and the Ceramic Liner in Total Hip Arthroplasty The Neck Is Not the Only Place Where Impingement Occurs
    Lee, Sunhyung
    Yoo, Jeong Joon
    Kim, Hee Joong
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2021, 103 (02): : 139 - 145
  • [2] Squeaking and neck-socket impingement in a ceramic total hip arthroplasty
    Eickmann, T
    Manaka, M
    Clarke, I
    Gustafson, A
    BIOCERAMICS 15, 2003, 240-2 : 849 - 852
  • [3] Revision total hip arthroplasty with metal on metal bearing for ceramic bearing fractures
    Park, Kyung-Soon
    Chan, Chee Ken
    Kim, Sung-Kyu
    Li, Qing Song
    Im, Chae-Jin
    Yoon, Taek-Rim
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (03) : 452 - 457
  • [4] Ceramic bearing surfaces in total hip arthroplasty
    Nelsen-Freund, EM
    Jacobs, JJ
    Maloney, WJ
    ARTHROPLASTY 2000: RECENT ADVANCES IN TOTAL JOINT REPLACEMENT, 2001, : 41 - 48
  • [5] Metal on metal bearing in total hip arthroplasty
    Alghamdi, A.
    Lavigne, M.
    Vendittoli, P. -A.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2012, 63 (02) : 85 - 99
  • [6] Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup
    Dragos Popescu
    X. Gallart
    S. Garcia
    G. Bori
    X. Tomas
    J. Riba
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 783 - 785
  • [7] Ceramic Liner Fracture in Total Hip Arthroplasty: A Case Report
    Tashtanov, Baikozho R.
    Korytkin, Andrey A.
    V. Pavlov, Vitalii
    Shubnyakov, Igor I.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2022, 28 (03): : 63 - 73
  • [8] Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup
    Popescu, Dragos
    Gallart, X.
    Garcia, S.
    Bori, G.
    Tomas, X.
    Riba, J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (08) : 783 - 785
  • [9] Revision total hip arthroplasty with sandwich-type ceramic on ceramic liner
    Lee, S. -H.
    Hwang, J. -H.
    Kim, B. -K.
    Hong, S. -H.
    Bioceramics and Alternative Bearings in Joint Arthroplasty, 2007, : 289 - 293
  • [10] Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup
    Hasegawa, M
    Sudo, A
    Hirata, H
    Uchida, A
    JOURNAL OF ARTHROPLASTY, 2003, 18 (05): : 658 - 661