Metal Neck and Liner Impingement in Ceramic Bearing Total Hip Arthroplasty

被引:21
|
作者
Lee, Young-Kyun [1 ]
Yoo, Jeong Loon [1 ]
Koo, Kyung-Hoi [1 ]
Yoon, Kang Sup [1 ]
Kim, Hee Jong [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Orthopaed Surg, Seoul, South Korea
关键词
total hip arthroplasty; impingement; ceramic liner; microcrack; failure; ACETABULAR COMPONENTS; EARLY OSTEOLYSIS; REPLACEMENT; HEAD; POLYETHYLENE; FRACTURE; WEAR; PROSTHESIS; STABILITY; SIMULATOR;
D O I
10.1002/jor.21246
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although impingement between the neck of the metallic stem and the ceramic liner has been suspected to be the cause of ceramic liner failure in ceramic-on-ceramic total hip arthroplasty (THA), no report has directly demonstrated microscopic damage on ceramic liner. We performed 18 reoperations on 18 patients who had undergone third generation ceramic-on-ceramic THA. Considering impingement, 16 patients, who were reoperated more than 1 year after previous ceramic bearing THA, were evaluated. Retrieved alumina liners, showing evidence of impingement, were examined by means of visual inspection and scanning electron microscopy (SEM). Four of the 16 hips showed neck notching and black stained liners, evidence of metallic neck to ceramic impingement. Impinged alumina bearings had been implanted for an average of 62.5 months (range: 35-99 months) before reoperation. SEM of the black stained area demonstrated disruptive wear and loss of surface integrity. Furthermore, one liner had multiple microcracks, and its cross-sectional SEM analysis revealed one microcrack propagating into the deep portion of the ceramic liner. Our observations suggest that metal neck-to-ceramic impingement in ceramic-on-ceramic THA can cause microcrack formation in ceramic liner. (C) 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 29:218-222, 2011
引用
收藏
页码:218 / 222
页数:5
相关论文
共 50 条
  • [41] Pseudotumor and repeated dislocation after total hip arthroplasty with ceramic-on-metal bearing: a case report
    Du, Yin-Qiao
    Luo, Tao
    Sun, Jing-Yang
    Ma, Hai-Yang
    Ni, Ming
    Zhou, Yong-Gang
    ANNALS OF PALLIATIVE MEDICINE, 2021, 10 (05) : 5818 - 5824
  • [42] Femoral head and neck dissociation after a total hip arthroplasty with a constrained acetabular liner
    Namba, RS
    Van der Reis, WL
    ORTHOPEDICS, 2000, 23 (05) : 489 - 491
  • [43] Metallosis due to impingement between the socket and the femoral neck in a metal-on-metal bearing total hip prosthesis - A case report
    Iida, H
    Kaneda, E
    Takada, H
    Uchida, K
    Kawanabe, K
    Nakamura, T
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (03): : 400 - 403
  • [44] Serum metal levels and bearing surfaces in total hip arthroplasty
    Rasquinha, Vijay J.
    Ranawat, Chitranjan S.
    Weiskopf, Joanne
    Rodriguez, Jose A.
    Skipor, Anastasia K.
    Jacobs, Joshua J.
    JOURNAL OF ARTHROPLASTY, 2006, 21 (06): : 47 - 52
  • [45] Comparison of metal on metal versus polyethylene-ceramic bearing in uncemented total hip arthroplasty in patients with haemophilic arthropathy
    Panotopoulos, Joannis
    Ay, Cihan
    Schuh, Reinhard
    Domayer, Stephan
    Funovics, Philipp
    Trieb, Klemens
    Wanivenhaus, Hugo
    Windhager, Reinhard
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (07) : 1369 - 1373
  • [46] Delayed Diagnosis of Low-symptomatic Ceramic Acetabular Liner Fracture in Ceramic-on-Ceramic Total Hip Arthroplasty
    Regis, Dario
    Sandri, Andrea
    Bartolozzi, Pietro
    ORTHOPEDICS, 2008, 31 (10) : 1041 - 1041
  • [47] Spinopelvic Motion and Impingement in Total Hip Arthroplasty
    McKnight, Braden M.
    Trasolini, Nicholas A.
    Dorr, Lawrence D.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (07): : S53 - S56
  • [48] Impingement in total hip arthroplasty: A geometric model
    Pryce, Gregory M.
    Sabu, Bismaya
    Al-Hajjar, Mazen
    Wilcox, Ruth K.
    Thompson, Jonathan
    Isaac, Graham H.
    Board, Tim
    Williams, Sophie
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2022, 236 (04) : 504 - 514
  • [49] The spatial location of impingement in total hip arthroplasty
    Yamaguchi, M
    Akisue, T
    Bauer, TW
    Hashimoto, Y
    JOURNAL OF ARTHROPLASTY, 2000, 15 (03): : 305 - 313
  • [50] Ceramic-on-ceramic catastrophic liner failure in total hip arthroplasty: Morphological and compositional analysis of fractured ceramic components
    Bistolfi, Alessandro
    Ferracini, Riccardo
    Lee, Gwo Chin
    Mellano, Danilo
    Guidotti, Claudio
    Baino, Francesco
    Verne, Enrica
    CERAMICS INTERNATIONAL, 2021, 47 (08) : 11029 - 11036