Metal Neck and Liner Impingement in Ceramic Bearing Total Hip Arthroplasty

被引:21
|
作者
Lee, Young-Kyun [1 ]
Yoo, Jeong Loon [1 ]
Koo, Kyung-Hoi [1 ]
Yoon, Kang Sup [1 ]
Kim, Hee Jong [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Orthopaed Surg, Seoul, South Korea
关键词
total hip arthroplasty; impingement; ceramic liner; microcrack; failure; ACETABULAR COMPONENTS; EARLY OSTEOLYSIS; REPLACEMENT; HEAD; POLYETHYLENE; FRACTURE; WEAR; PROSTHESIS; STABILITY; SIMULATOR;
D O I
10.1002/jor.21246
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although impingement between the neck of the metallic stem and the ceramic liner has been suspected to be the cause of ceramic liner failure in ceramic-on-ceramic total hip arthroplasty (THA), no report has directly demonstrated microscopic damage on ceramic liner. We performed 18 reoperations on 18 patients who had undergone third generation ceramic-on-ceramic THA. Considering impingement, 16 patients, who were reoperated more than 1 year after previous ceramic bearing THA, were evaluated. Retrieved alumina liners, showing evidence of impingement, were examined by means of visual inspection and scanning electron microscopy (SEM). Four of the 16 hips showed neck notching and black stained liners, evidence of metallic neck to ceramic impingement. Impinged alumina bearings had been implanted for an average of 62.5 months (range: 35-99 months) before reoperation. SEM of the black stained area demonstrated disruptive wear and loss of surface integrity. Furthermore, one liner had multiple microcracks, and its cross-sectional SEM analysis revealed one microcrack propagating into the deep portion of the ceramic liner. Our observations suggest that metal neck-to-ceramic impingement in ceramic-on-ceramic THA can cause microcrack formation in ceramic liner. (C) 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 29:218-222, 2011
引用
收藏
页码:218 / 222
页数:5
相关论文
共 50 条
  • [21] Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces
    Yoon, TR
    Rowe, SM
    Jung, ST
    Seon, KJ
    Maloney, WJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (10): : 1459 - 1468
  • [22] What factors predict ceramic liner malseating after ceramic-on-ceramic total hip arthroplasty?
    Higuchi, Yoshitoshi
    Seki, Taisuke
    Takegami, Yasuhiko
    Osawa, Yusuke
    Kusano, Taiki
    Ishiguro, Naoki
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (03) : 453 - 459
  • [23] Revision total hip arthroplasty by a ceramic bearing surface after a third- and fourth-generation ceramic head or liner fracture
    Marmor, Simon
    Yaacoub, Jean-Jacques
    Aubert, Thomas
    Graff, Wilfrid
    Mouton, Antoine
    Le Strat, Vincent
    Lhotellier, Luc
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (05) : 1197 - 1202
  • [24] Revision total hip arthroplasty by a ceramic bearing surface after a third- and fourth-generation ceramic head or liner fracture
    Simon Marmor
    Jean-Jacques Yaacoub
    Thomas Aubert
    Wilfrid Graff
    Antoine Mouton
    Vincent Le Strat
    Luc Lhotellier
    International Orthopaedics, 2023, 47 : 1197 - 1202
  • [25] A simple technique for ceramic liner extraction during revision total hip arthroplasty
    Whiting, F.
    Lewis, C.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2014, 96 (07) : 549 - 550
  • [26] Ceramic Liner Fractures Presenting as Squeaking After Primary Total Hip Arthroplasty
    Abdel, Matthew P.
    Heyse, Thomas J.
    Elpers, Marcella E.
    Mayman, David J.
    Su, Edwin P.
    Pellicci, Paul M.
    Wright, Timothy M.
    Padgett, Douglas E.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (01): : 27 - 31
  • [27] Protrusion of acetabular screws as a cause of liner fracture in ceramic-on-ceramic total hip arthroplasty
    Natera Cisneros, L.
    Crusi, X.
    TRAUMA-SPAIN, 2014, 25 (01): : 37 - 39
  • [28] Comparison of uncemented total hip arthroplasty between metal on metal and ceramic on polyethylene bearing surfaces in young patients
    Kim, Y. -H.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2007, : 73 - 81
  • [29] Comparison of metal on metal versus polyethylene–ceramic bearing in uncemented total hip arthroplasty in patients with haemophilic arthropathy
    Joannis Panotopoulos
    Cihan Ay
    Reinhard Schuh
    Stephan Domayer
    Philipp Funovics
    Klemens Trieb
    Hugo Wanivenhaus
    Reinhard Windhager
    International Orthopaedics, 2014, 38 : 1369 - 1373
  • [30] Metal on Metal or Ceramic on Ceramic for Cementless Total Hip Arthroplasty: A Meta-Analysis
    Lee, Young-Kyun
    Yoon, Byung-Ho
    Choi, Yun Seong
    Jo, Woo-Lam
    Ha, Yong-Chan
    Koo, Kyung-Hoi
    JOURNAL OF ARTHROPLASTY, 2016, 31 (11): : 2637 - 2645