Full-range k-domain linearization in spectral-domain optical coherence tomography

被引:66
|
作者
Jeon, Mansik [2 ]
Kim, Jeehyun [2 ]
Jung, Unsang [2 ]
Lee, Changho [2 ]
Jung, Woonggyu [1 ]
Boppart, Stephen A. [1 ,3 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[2] Kyungpook Natl Univ, Sch Elect Engn & Comp Sci, Taegu, South Korea
[3] Univ Illinois, Dept Elect & Comp Engn Bioengn & Internal Med, Urbana, IL 61801 USA
基金
美国国家卫生研究院; 新加坡国家研究基金会;
关键词
D O I
10.1364/AO.50.001158
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A full-bandwidth k-domain linearization method for spectral-domain optical coherence tomography (SD-OCT) is demonstrated. The method uses information of the wavenumber-pixel-position provided by a translating-slit-based wavelength filter. For calibration purposes, the filter is placed either after a broad-band source or at the end of the sample path, and the filtered spectrum with a narrowed line width (similar to 0.5 nm) is incident on a line-scan camera in the detection path. The wavelength-swept spectra are co-registered with the pixel positions according to their central wavelengths, which can be automatically measured with an optical spectrum analyzer. For imaging, the method does not require a filter or a software recalibration algorithm; it simply resamples the OCT signal from the detector array without employing rescaling or interpolation methods. The accuracy of k-linearization is maximized by increasing the k-linearization order, which is known to be a crucial parameter for maintaining a narrow point-spread function ( PSF) width at increasing depths. The broadening effect is studied by changing the k-linearization order by undersampling to search for the optimal value. The system provides more position information, surpassing the optimum without compromising the imaging speed. The proposed full-range k-domain linearization method can be applied to SD-OCT systems to simplify their hardware/software, increase their speed, and improve the axial image resolution. The experimentally measured width of PSF in air has an FWHM of 8 mu m at the edge of the axial measurement range. At an imaging depth of 2.5 mm, the sensitivity of the full-range calibration case drops less than 10 dB compared with the uncompensated case. (C) 2011 Optical Society of America
引用
收藏
页码:1158 / 1163
页数:6
相关论文
共 50 条
  • [31] Experiment research on spectral-domain optical coherence tomography
    Chen, Yuping
    Zhao, Hong
    Yang, Qi
    Wang, Zhao
    Zhang, Lu
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2008, 42 (07): : 815 - 817
  • [32] Spectral-domain optical coherence tomography of peripapillary staphyloma
    Woo, Se Joon
    Hwang, Jeong-Min
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (11) : 1573 - 1574
  • [33] Measurement of ocular axial length using full-range spectral-domain low-coherence interferometry
    王毅
    冯亮
    朱礼达
    周红仙
    马振鹤
    ChineseOpticsLetters, 2018, 16 (03) : 61 - 65
  • [34] Measurement of ocular axial length using full-range spectral-domain low-coherence interferometry
    Wang, Yi
    Feng, Liang
    Zhu, Lida
    Zhou, Hongxian
    Ma, Zhenhe
    CHINESE OPTICS LETTERS, 2018, 16 (03)
  • [35] In vivo full depth of eye-imaging spectral-domain optical coherence tomography
    Dai, Cuixia
    Zhou, Chuanqing
    Jiao, Shuliang
    Xi, Peng
    Ren, Qiushi
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XXXIV, 2011, 8135
  • [36] Microcirculation imaging based on full-range high-speed spectral domain correlation mapping optical coherence tomography
    Subhash, Hrebesh M.
    Leahy, Martin J.
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (02)
  • [37] Extended in vivo anterior eye-segment imaging with full-range complex spectral domain optical coherence tomography
    Jungwirth, Johannes
    Baumann, Bernhard
    Pircher, Michael
    Goetzinger, Erich
    Hitzenberger, Christoph K.
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (05)
  • [38] High speed full range complex spectral domain optical coherence tomography
    Götzinger, E
    Pircher, M
    Leitgeb, RA
    Hitzenberger, CK
    OPTICS EXPRESS, 2005, 13 (02): : 583 - 594
  • [40] Full-range Fourier domain Doppler optical coherence tomography based on sinusoidal phase modulation
    Nan, Nan
    Wang, Xiangzhao
    Bu, Peng
    Li, Zhongliang
    Guo, Xin
    Chen, Yan
    Wang, Xuan
    Yuan, Fenghua
    Sasaki, Osami
    APPLIED OPTICS, 2014, 53 (12) : 2669 - 2676