A full-bandwidth k-domain linearization method for spectral-domain optical coherence tomography (SD-OCT) is demonstrated. The method uses information of the wavenumber-pixel-position provided by a translating-slit-based wavelength filter. For calibration purposes, the filter is placed either after a broad-band source or at the end of the sample path, and the filtered spectrum with a narrowed line width (similar to 0.5 nm) is incident on a line-scan camera in the detection path. The wavelength-swept spectra are co-registered with the pixel positions according to their central wavelengths, which can be automatically measured with an optical spectrum analyzer. For imaging, the method does not require a filter or a software recalibration algorithm; it simply resamples the OCT signal from the detector array without employing rescaling or interpolation methods. The accuracy of k-linearization is maximized by increasing the k-linearization order, which is known to be a crucial parameter for maintaining a narrow point-spread function ( PSF) width at increasing depths. The broadening effect is studied by changing the k-linearization order by undersampling to search for the optimal value. The system provides more position information, surpassing the optimum without compromising the imaging speed. The proposed full-range k-domain linearization method can be applied to SD-OCT systems to simplify their hardware/software, increase their speed, and improve the axial image resolution. The experimentally measured width of PSF in air has an FWHM of 8 mu m at the edge of the axial measurement range. At an imaging depth of 2.5 mm, the sensitivity of the full-range calibration case drops less than 10 dB compared with the uncompensated case. (C) 2011 Optical Society of America
引用
收藏
页码:1158 / 1163
页数:6
相关论文
共 50 条
  • [21] Spectral-domain optical coherence tomography of peripapillary staphyloma
    Se Joon Woo
    Jeong-Min Hwang
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 : 1573 - 1574
  • [22] Spectral-domain optical coherence tomography for endoscopic imaging
    Chen, Xiaodong
    Li, Qiao
    Li, Wanhui
    Wang, Yi
    Yu, Daoyin
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI, 2007, 6429
  • [23] FEASIBILITY OF INTRASURGICAL SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY
    Binder, Susanne
    Falkner-Radler, Christiane I.
    Hauger, Christoph
    Matz, Holger
    Glittenberg, Carl
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (07): : 1332 - 1336
  • [24] Orthogonal dispersive spectral-domain optical coherence tomography
    Bao, Wen
    Ding, Zhihua
    Li, Peng
    Chen, Zhiyan
    Shen, Yi
    Wang, Chuan
    OPTICS EXPRESS, 2014, 22 (08): : 10081 - 10090
  • [25] Spectral-Domain Optical Coherence Tomography in Hydroxychloroquine Retinopathy
    Johnston, Janine L.
    Darvill, Patty
    Thomson, Glen T. D.
    OPHTHALMOLOGY, 2015, 122 (03) : 651 - 652
  • [26] Sensitivity and Specificity of Spectral-Domain Optical Coherence Tomography
    Kawai, S.
    Shimizu, S.
    Shinoda, K.
    Suzuki, Y.
    Mizota, A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [27] COMMOTIO RETINAE WITH SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY
    Oh, Jaeryung
    Jung, Jae-Hoon
    Moon, Sang Woong
    Song, Su Jeong
    Yu, Hyeong Gon
    Cho, Hee Yoon
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (10): : 2044 - 2049
  • [28] Spectral-domain optical coherence tomography of macula in myopia
    Choovuthayakorn, Janejit
    Laowong, Taksaorn
    Watanachai, Nawat
    Patikulsila, Direk
    Chaikitmongkol, Voraporn
    INTERNATIONAL OPHTHALMOLOGY, 2016, 36 (03) : 319 - 325
  • [29] Spectral-domain optical coherence tomography of macula in myopia
    Janejit Choovuthayakorn
    Taksaorn Laowong
    Nawat Watanachai
    Direk Patikulsila
    Voraporn Chaikitmongkol
    International Ophthalmology, 2016, 36 : 319 - 325
  • [30] Spectral-Domain Optical Coherence Tomography for Macular Edema
    Badaro, Emmerson
    Novais, Eduardo
    Prodocimo, Larissa Maria
    Sallum, JulianaM. Ferraz
    SCIENTIFIC WORLD JOURNAL, 2014,