Collimator-detector response compensation in quantitative SPECT reconstruction

被引:10
|
作者
Liu, Shaoying [1 ]
Farncombe, Troy H. [2 ]
机构
[1] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON, Canada
[2] Hamilton Hlth Sci, Dept Nucl Sci, Hamilton, ON, Canada
关键词
D O I
10.1109/NSSMIC.2007.4436983
中图分类号
O59 [应用物理学];
学科分类号
摘要
The purpose of this study was to investigate the importance of collimator-detector response compensation in single photon emission computed tomography (SPECT). The compensation methods included in this study addressed there important degrading factors, which are attenuation, scatter and collimator-detector response (CDR). Geometric response (GR) and septal penetration (SP) are two most important component of collimator-detector response. The compensation work has been divided into two general categories: one is GR compensation based reconstruction (GR-RECON), which includes attenuation scatter and geometric response compensations, and the other one is GR-SP compensation based reconstruction (GR-SP-RECON which consists of attenuation, scatter geometric response and septal penetration compensations. Ordered-subset expectation maximization (OS-EM) method is applied as the reconstruction framework. SIMIND Monte Carlo (MC) code is incorporated in the forward projection. Multiple projection sampling convolution-based forced detection (MP-CFD) is used here to accelerate the MC code. The convolution kernels in CFD are generated by the ray-tracing (RT) method. In order to further increase the convergence speed, the mod of attenuation and collimator-detector response are included in the backprojection step. In order to assess the quantitative accuracy of the collimator-detector response compensation, the reconstruction images of cylinder, four different size spheres in various medium, and NURBS-based Cardiac-Torso (NCAT) phantom are evaluated using I-131 and high energy general resolution (HEGR) colli-mators. The reconstruction images including GR compensation appear very obvious collimator dependent Gibbs ringing artifact The quantitative estimation of the spheres and NURBS-based cardiac-torso (NCAT) phantom has denoted the high accuracy of GR-SP-RECON, whereas, a lot of quantitative activity will be mistakenly estimated in the background using GR-RECON.
引用
收藏
页码:3955 / +
页数:3
相关论文
共 50 条
  • [41] Nonuniform collimator sensitivity: Improved precision for quantitative SPECT
    Kijewski, MF
    Muller, SP
    Moore, SC
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (01) : 151 - 156
  • [42] Compensation for non-stationary detector response in analytical varying focal-length fan-beam SPECT reconstruction
    Li, TF
    Wen, JH
    Liang, ZR
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1686 - 1690
  • [43] Implementation and evaluation of fast iterative reconstruction based compensation for attenuation, detector response blurring and scatter in myocardial in perfusion SPECT.
    Frey, EC
    Kadrmas, DJ
    Tsui, BMW
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 120P - 120P
  • [44] Quantitative accuracy in cardiac SPECT:: What are the respective roles of attenuation, collimator response and scatter corrections?
    El Fakhri, G
    Buvat, I
    Pélégrini, M
    Benali, H
    Di Paola, R
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 179P - 179P
  • [45] Image reconstruction in SPECT with a half detector
    Pan, XC
    Sidky, EY
    Zou, Y
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 774 - 778
  • [46] Evaluation of an efficient compensation method for quantitative fan-beam brain SPECT reconstruction
    Liu, TF
    Wen, JH
    Han, GP
    Lu, HB
    Liang, ZR
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (02) : 170 - 179
  • [47] Animal SPECT Imaging on a Shared PET/SPECT Ring Detector with Elliptical-pinhole Collimator
    Wu, Jing
    Chen, Si
    Gong, Guanghua
    Jiang, Nianming
    He, Feng
    Wang, Shi
    Liu, Yaqiang
    Cheng, Jianping
    Ma, Tianyu
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [48] COMPENSATION OF SPATIAL SYSTEM RESPONSE IN SPECT WITH CONJUGATE-GRADIENT RECONSTRUCTION TECHNIQUE
    FORMICONI, AR
    PUPI, A
    PASSERI, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (01): : 69 - 84
  • [49] A FILTERING TECHNIQUE TO COMPENSATE FOR DETECTOR RESPONSE IN CONVERGING-BEAM SPECT RECONSTRUCTION
    CAO, ZJ
    TSUI, BMW
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (08): : 1281 - 1293
  • [50] A FILTERING TECHNIQUE TO COMPENSATE FOR DETECTOR RESPONSE IN CONVERGING-BEAM SPECT RECONSTRUCTION
    CAO, ZJ
    TSUI, BMW
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P191 - P191