The purpose of this study was to investigate the importance of collimator-detector response compensation in single photon emission computed tomography (SPECT). The compensation methods included in this study addressed there important degrading factors, which are attenuation, scatter and collimator-detector response (CDR). Geometric response (GR) and septal penetration (SP) are two most important component of collimator-detector response. The compensation work has been divided into two general categories: one is GR compensation based reconstruction (GR-RECON), which includes attenuation scatter and geometric response compensations, and the other one is GR-SP compensation based reconstruction (GR-SP-RECON which consists of attenuation, scatter geometric response and septal penetration compensations. Ordered-subset expectation maximization (OS-EM) method is applied as the reconstruction framework. SIMIND Monte Carlo (MC) code is incorporated in the forward projection. Multiple projection sampling convolution-based forced detection (MP-CFD) is used here to accelerate the MC code. The convolution kernels in CFD are generated by the ray-tracing (RT) method. In order to further increase the convergence speed, the mod of attenuation and collimator-detector response are included in the backprojection step. In order to assess the quantitative accuracy of the collimator-detector response compensation, the reconstruction images of cylinder, four different size spheres in various medium, and NURBS-based Cardiac-Torso (NCAT) phantom are evaluated using I-131 and high energy general resolution (HEGR) colli-mators. The reconstruction images including GR compensation appear very obvious collimator dependent Gibbs ringing artifact The quantitative estimation of the spheres and NURBS-based cardiac-torso (NCAT) phantom has denoted the high accuracy of GR-SP-RECON, whereas, a lot of quantitative activity will be mistakenly estimated in the background using GR-RECON.
引用
收藏
页码:3955 / +
页数:3
相关论文
共 50 条
  • [32] Fast Monte Carlo-simulator with full collimator and detector response modelling for SPECT
    Antti O. Sohlberg
    Markus T. Kajaste
    Annals of Nuclear Medicine, 2012, 26 : 92 - 98
  • [33] Fast Monte Carlo-simulator with full collimator and detector response modelling for SPECT
    Sohlberg, Antti O.
    Kajaste, Markus T.
    ANNALS OF NUCLEAR MEDICINE, 2012, 26 (01) : 92 - 98
  • [34] Angular Response Function parameterization for collimator/detector in SPECT simulations within the GATE toolkit
    Descourt, P.
    Du, Y.
    Song, X.
    Frey, E. C.
    Tsui, B. M. W.
    Visvikis, D.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4235 - +
  • [35] A fast iterative GPU-based reconstruction algorithm for SPECT imaging involving collimator and attenuation compensation
    Szlavecz, A.
    Hesz, G.
    Puskas, Z.
    Kari, B.
    Partos, O.
    Gyoerke, T.
    Buekki, T.
    Domonkos, B.
    Benyo, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S284 - S284
  • [36] QUANTITATIVE SPECT BRAIN IMAGING - EFFECTS OF ATTENUATION AND DETECTOR RESPONSE
    GILLAND, DR
    JASZCZAK, RJ
    BOWSHER, JE
    TURKINGTON, TG
    LIANG, Z
    GREER, KL
    COLEMAN, RE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (03) : 295 - 299
  • [37] Impact of different collimator response models on quantitative 177Lu-SPECT reconstructions
    Claeys, W.
    Deckers, W.
    Nuttens, V.
    Deroose, C.
    Goffin, K.
    Baete, K.
    Koole, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S161 - S161
  • [38] PARALLEL-PLUS COLLIMATOR FOR SPECT AND ITS RECONSTRUCTION
    WU, C
    GUNTER, DL
    CHEN, CT
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P33 - P34
  • [39] Optimizing Collimator Resolution/Sensitivity in SPECT Iterative Reconstruction
    Strologas, John
    Metzler, Scott
    Zheng, Xiaofen
    Chang, Wei
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [40] Characterization of a SPECT pinhole collimator for optimal detector usage (the lofthole)
    Deprez, Karel
    Pato, Lara R. V.
    Vandenberghe, Stefaan
    Van Holen, Roel
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04): : 859 - 885