Collimator-detector response compensation in quantitative SPECT reconstruction

被引:10
|
作者
Liu, Shaoying [1 ]
Farncombe, Troy H. [2 ]
机构
[1] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON, Canada
[2] Hamilton Hlth Sci, Dept Nucl Sci, Hamilton, ON, Canada
关键词
D O I
10.1109/NSSMIC.2007.4436983
中图分类号
O59 [应用物理学];
学科分类号
摘要
The purpose of this study was to investigate the importance of collimator-detector response compensation in single photon emission computed tomography (SPECT). The compensation methods included in this study addressed there important degrading factors, which are attenuation, scatter and collimator-detector response (CDR). Geometric response (GR) and septal penetration (SP) are two most important component of collimator-detector response. The compensation work has been divided into two general categories: one is GR compensation based reconstruction (GR-RECON), which includes attenuation scatter and geometric response compensations, and the other one is GR-SP compensation based reconstruction (GR-SP-RECON which consists of attenuation, scatter geometric response and septal penetration compensations. Ordered-subset expectation maximization (OS-EM) method is applied as the reconstruction framework. SIMIND Monte Carlo (MC) code is incorporated in the forward projection. Multiple projection sampling convolution-based forced detection (MP-CFD) is used here to accelerate the MC code. The convolution kernels in CFD are generated by the ray-tracing (RT) method. In order to further increase the convergence speed, the mod of attenuation and collimator-detector response are included in the backprojection step. In order to assess the quantitative accuracy of the collimator-detector response compensation, the reconstruction images of cylinder, four different size spheres in various medium, and NURBS-based Cardiac-Torso (NCAT) phantom are evaluated using I-131 and high energy general resolution (HEGR) colli-mators. The reconstruction images including GR compensation appear very obvious collimator dependent Gibbs ringing artifact The quantitative estimation of the spheres and NURBS-based cardiac-torso (NCAT) phantom has denoted the high accuracy of GR-SP-RECON, whereas, a lot of quantitative activity will be mistakenly estimated in the background using GR-RECON.
引用
收藏
页码:3955 / +
页数:3
相关论文
共 50 条
  • [21] Quantitative SPECT: Recent developments in detector response, attenuation and scatter compensation techniques
    Zaidi, H
    PHYSICA MEDICA, 1996, 12 (03) : 101 - 117
  • [22] Compensation for collimator detector response in tumor SPECT imaging using 111In with dual energy photons.
    Sayeram, S
    Tsui, BM
    Zhao, XD
    Frey, EC
    Falen, SW
    McCartney, WH
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 197P - 197P
  • [23] COMPENSATION FOR ATTENUATION, SCATTER, AND DETECTOR RESPONSE IN SPECT RECONSTRUCTION VIA ITERATIVE FBP METHODS
    LIANG, ZR
    MEDICAL PHYSICS, 1993, 20 (04) : 1097 - 1106
  • [24] COMPENSATION FOR COLLIMATOR DIVERGENCE IN SPECT USING INVERSE MONTE-CARLO RECONSTRUCTION
    FLOYD, CE
    JASZCZAK, RJ
    MANGLOS, SH
    COLEMAN, RE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 784 - 787
  • [25] The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery
    Kim, J.
    Son, H.
    Lee, J.
    Park, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S746 - S747
  • [26] LROC analysis of detector-response compensation in SPECT
    Gifford, HC
    King, MA
    Wells, RG
    Hawkins, WG
    Narayanan, MV
    Pretorius, PH
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 463 - 473
  • [27] Correction for respiration artefacts in myocardial perfusion SPECT is more effective when reconstructions supporting collimator detector response compensation are applied
    Kovalski, Gil
    Keidar, Zohar
    Frenkel, Alex
    Israel, Ora
    Azhari, Haim
    JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (06) : 949 - 955
  • [28] Correction for respiration artefacts in myocardial perfusion SPECT is more effective when reconstructions supporting collimator detector response compensation are applied
    Gil Kovalski
    Zohar Keidar
    Alex Frenkel
    Ora Israel
    Haim Azhari
    Journal of Nuclear Cardiology, 2009, 16 : 949 - 955
  • [29] SPECT imaging with a semiconductor detector and a diverging collimator
    Fukizawa, Mizuho
    Ogawa, Koichi
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 836 - 839
  • [30] Accurate 3D detector response compensation in spect using multigrid iterative reconstruction methods
    Tsui, BMW
    Zhao, XD
    Frey, EC
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1151 - 1155