Collimator-detector response compensation in quantitative SPECT reconstruction

被引:10
|
作者
Liu, Shaoying [1 ]
Farncombe, Troy H. [2 ]
机构
[1] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON, Canada
[2] Hamilton Hlth Sci, Dept Nucl Sci, Hamilton, ON, Canada
关键词
D O I
10.1109/NSSMIC.2007.4436983
中图分类号
O59 [应用物理学];
学科分类号
摘要
The purpose of this study was to investigate the importance of collimator-detector response compensation in single photon emission computed tomography (SPECT). The compensation methods included in this study addressed there important degrading factors, which are attenuation, scatter and collimator-detector response (CDR). Geometric response (GR) and septal penetration (SP) are two most important component of collimator-detector response. The compensation work has been divided into two general categories: one is GR compensation based reconstruction (GR-RECON), which includes attenuation scatter and geometric response compensations, and the other one is GR-SP compensation based reconstruction (GR-SP-RECON which consists of attenuation, scatter geometric response and septal penetration compensations. Ordered-subset expectation maximization (OS-EM) method is applied as the reconstruction framework. SIMIND Monte Carlo (MC) code is incorporated in the forward projection. Multiple projection sampling convolution-based forced detection (MP-CFD) is used here to accelerate the MC code. The convolution kernels in CFD are generated by the ray-tracing (RT) method. In order to further increase the convergence speed, the mod of attenuation and collimator-detector response are included in the backprojection step. In order to assess the quantitative accuracy of the collimator-detector response compensation, the reconstruction images of cylinder, four different size spheres in various medium, and NURBS-based Cardiac-Torso (NCAT) phantom are evaluated using I-131 and high energy general resolution (HEGR) colli-mators. The reconstruction images including GR compensation appear very obvious collimator dependent Gibbs ringing artifact The quantitative estimation of the spheres and NURBS-based cardiac-torso (NCAT) phantom has denoted the high accuracy of GR-SP-RECON, whereas, a lot of quantitative activity will be mistakenly estimated in the background using GR-RECON.
引用
收藏
页码:3955 / +
页数:3
相关论文
共 50 条
  • [1] The usefulness of collimator-detector response compensation algorithm in iterative reconstruction
    Seung, Joni Min
    Kim, Joon Hyun
    Lee, Hong Jae
    Kim, Hyun Joo
    Lee, Jae Sun
    Lee, Dong Soo
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [2] Collimator-Detector Response Compensation in Preclinical SPECT using STIR Framework
    Mahani, H.
    Raisali, G.
    Kamali-Asl, A.
    Ay, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S500 - S500
  • [3] Simultaneous attenuation and collimator-detector response compensation in dynamic myocardial SPECT.
    Tsui, BMW
    Frey, EC
    Zhao, XD
    LaCroix, KJ
    Lalush, DS
    Peterious, PH
    King, MA
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 61 - 61
  • [4] Quantitative rotating multisegment slant-hole SPECT mammography with attenuation and collimator-detector response compensation
    Xu, Jingyan
    Liu, Chi
    Wang, Yuchuan
    Frey, Eric C.
    Tsui, Benjamin A. W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (07) : 906 - 916
  • [5] Sampling requirements for SPECT: Iterative reconstruction techniques utilising a collimator-detector response function
    Jenkins, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S269 - S269
  • [6] Evaluation of a collimator-detector response compensation method in SPECT images. Comparison of image quality with "Brain SPECT" and Evolution™
    Fall, S.
    Bailly, P.
    Meyer, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S269 - S269
  • [7] Validation and evaluation of model-based scatter and collimator-detector response compensation for myocardial SPECT.
    Frey, EC
    Song, XY
    Wang, WT
    Tocharoenchai, C
    Tsui, BMW
    Wilk, M
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 132P - 132P
  • [8] Performance of a SPECT collimator-detector response reconstruction algorithm: phantom studies and validation in inflammation clinical studies
    Arosio, M.
    Pasquali, C.
    Crivellaro, C.
    De Ponti, E.
    Morzenti, S.
    Guerra, L.
    Crespi, A.
    Messa, C.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 55 (06): : 671 - 679
  • [9] Correction for Collimator-Detector Response in SPECT Using Point Spread Function Template
    Chun, Se Young
    Fessler, Jeffrey A.
    Dewaraja, Yuni K.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (02) : 295 - 305
  • [10] Correction for collimator-detector response (CDR) in quantitative SPECT using point spread function (PSF) template approach
    Chun, Se Young
    Fessler, Jeffrey
    Dewaraja, Yuni
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53