Implications of three-dimensional modeling of tibia for intramedullary nail fixation: A virtual study on Asian cadaver tibia

被引:6
|
作者
Byun, Seong-Eun [1 ]
Jung, Gu-Hee [2 ]
机构
[1] CHA Univ, CHA Bundang Med Ctr, Dept Orthopaed Surg, Pochon, South Korea
[2] Gyeongsang Natl Univ, Dept Orthopaed Surg, Coll Med, Changwon Hosp, 1 Samjeongja Ro, Changwon Si 51472, Gyeongsangnam D, South Korea
关键词
Tibia; Fracture; Intramedullary nail; Three-dimensional modeling; Entry point; INSERTION POINT; TORSION;
D O I
10.1016/j.injury.2019.10.070
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: To determine the optimal entry point (EP) of intramedullary nail (IMN) fixation and introduce a consistent landmark for practical application by analyzing three-dimensional (3D) modeling and virtual implantation. Materials and methods: A total of 104 cadaveric femurs (50 males and 54 females) underwent continuous 1.0 mm slice computed tomography (CT) scans. CT images were imported into Mimics (R) software to reconstruct 3D model of tibiofibular bone with medullary canal. Expert Tibial Nail (ETN (R), empty set12mm/Length 315 mm) was processed into a 3D model at the actual size and optimally implanted in the tibia. After IMN was aligned in a neutral position, it was defined as a true AP projection. In the true AP projection, optimal EP and relationship with adjacent structures were assessed based on the degree of tibial rotation. Results: EP was placed eccentrically around the lateral tibial spine in cephalad view and in true AP projection in all models. In true AP projection, the overlapping point between fibular tip and cortical margin of lateral condyle was placed lateral to the fibular tip in 62 models, and exactly matched with fibular tip in 42 models. As tibia rotates, the position of EP in the AP view changes. When tibia was externally rotated, EP was located to the lateral, not the medial side of the lateraltibialspine. The obliquity of guide wire also changed withtibialrotation; the obliquity of guide wire aligned in a straight in true AP projection. Conclusion: Optimal determination of EP and guide wire direction should be performed by considering the overlapping point that should be placed to just or lateral side of fibular tip in AP projection. Compared with fibular bisector line, the overlapping point is also useful as a practical landmark for making true AP projection and determining optimal EP. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:505 / 509
页数:5
相关论文
共 50 条
  • [41] Native tibia valga: a potential source of varus malreduction during intramedullary tibial nail fixation of tibial shaft fractures
    Nicholas J. Tucker
    Michael M. Hadeed
    Cyril Mauffrey
    Joshua A. Parry
    International Orthopaedics, 2022, 46 : 1165 - 1173
  • [42] Three-dimensional morphologic features of Asian atypical femur and clinical implications of cephalomedullary nail fixation: Computational measurement at actual size
    Lee, Kyung-Jae
    Kim, Beom-Soo
    Kim, Kun-Tae
    Jung, Gu-Hee
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (12): : 4090 - 4098
  • [43] Usefulness of synchrotron radiation for three-dimensional microstructure analysis of the mouse tibia
    Kim, Subok
    Jang, Sanghun
    Lee, Onseok
    MICROSCOPY RESEARCH AND TECHNIQUE, 2019, 82 (05) : 564 - 571
  • [44] Open fractures of the tibia treated by immediate intramedullary tibial nail insertion without reaming: A prospective study
    Kakar, S.
    Tornetta, P., III
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (03) : 153 - 157
  • [45] Three-dimensional measurement of the femur using clinical ultrasound: Developing a basis for image guided intramedullary nail fixation of the femur
    Young, DI
    Staniforth, SM
    Hu, RW
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 1220 - 1228
  • [46] Three-dimensional analysis of shape variations and symmetry of the fibula, tibia, calcaneus and talus
    Tumer, Nazli
    Arbabi, Vahid
    Gielis, Willem Paul
    de Jong, Pim A.
    Weinans, Harrie
    Tuijthof, Gabrielle J. M.
    Zadpoor, Amir A.
    JOURNAL OF ANATOMY, 2019, 234 (01) : 132 - 144
  • [47] Comparison between three-dimensional CT and conventional radiography in proximal tibia morphology
    Zhang, Yijie
    Chen, Yanxi
    Qiang, Minfei
    Zhang, Kun
    Li, Haobo
    Jiang, Yuchen
    Jia, Xiaoyang
    MEDICINE, 2018, 97 (30)
  • [48] Tibia vara in Asians: Myth or fact? Verification with three-dimensional computed tomography
    Ho, Jade Pei Yuik
    Merican, Azhar Mahmood
    Ayob, Khairul Anwar
    Sulaiman, Shahrul-Hisham
    Hashim, Muhammad Sufian
    JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (01)
  • [49] SSOP Three-Dimensional Reconstruction of Tibia and Fibula for Applications in Biomechanical Fracture Models
    Mejia-Gallon, Valentina
    Camila Naranjo-Cardona, Maria
    Atehortua Carmona, Juan
    Vallejo Pareja, Samuel
    Felipe Santa-Marin, Juan
    Posada, Viviana M.
    Ramirez, Juan
    INGENIERIA, 2021, 26 (03): : 450 - 464
  • [50] A Registration Method for Three-Dimensional Analysis of Bone Mineral Density in the Proximal Tibia
    Babel, Hugo
    Waegeli, Loic
    Sonmez, Berke
    Thiran, Jean-Philippe
    Omoumi, Patrick
    Jolles, Brigitte M.
    Favre, Julien
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2021, 143 (01):