Implications of three-dimensional modeling of tibia for intramedullary nail fixation: A virtual study on Asian cadaver tibia

被引:6
|
作者
Byun, Seong-Eun [1 ]
Jung, Gu-Hee [2 ]
机构
[1] CHA Univ, CHA Bundang Med Ctr, Dept Orthopaed Surg, Pochon, South Korea
[2] Gyeongsang Natl Univ, Dept Orthopaed Surg, Coll Med, Changwon Hosp, 1 Samjeongja Ro, Changwon Si 51472, Gyeongsangnam D, South Korea
关键词
Tibia; Fracture; Intramedullary nail; Three-dimensional modeling; Entry point; INSERTION POINT; TORSION;
D O I
10.1016/j.injury.2019.10.070
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: To determine the optimal entry point (EP) of intramedullary nail (IMN) fixation and introduce a consistent landmark for practical application by analyzing three-dimensional (3D) modeling and virtual implantation. Materials and methods: A total of 104 cadaveric femurs (50 males and 54 females) underwent continuous 1.0 mm slice computed tomography (CT) scans. CT images were imported into Mimics (R) software to reconstruct 3D model of tibiofibular bone with medullary canal. Expert Tibial Nail (ETN (R), empty set12mm/Length 315 mm) was processed into a 3D model at the actual size and optimally implanted in the tibia. After IMN was aligned in a neutral position, it was defined as a true AP projection. In the true AP projection, optimal EP and relationship with adjacent structures were assessed based on the degree of tibial rotation. Results: EP was placed eccentrically around the lateral tibial spine in cephalad view and in true AP projection in all models. In true AP projection, the overlapping point between fibular tip and cortical margin of lateral condyle was placed lateral to the fibular tip in 62 models, and exactly matched with fibular tip in 42 models. As tibia rotates, the position of EP in the AP view changes. When tibia was externally rotated, EP was located to the lateral, not the medial side of the lateraltibialspine. The obliquity of guide wire also changed withtibialrotation; the obliquity of guide wire aligned in a straight in true AP projection. Conclusion: Optimal determination of EP and guide wire direction should be performed by considering the overlapping point that should be placed to just or lateral side of fibular tip in AP projection. Compared with fibular bisector line, the overlapping point is also useful as a practical landmark for making true AP projection and determining optimal EP. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:505 / 509
页数:5
相关论文
共 50 条
  • [31] UK Fixation of Distal Tibia Fractures (UK FixDT): protocol for a randomised controlled trial of 'locking' plate fixation versus intramedullary nail fixation in the treatment of adult patients with a displaced fracture of the distal tibia
    Achten, Juul
    Parsons, Nicholas R.
    McGuinness, Katie R.
    Petrou, Stavros
    Lamb, Sarah E.
    Costa, Matthew L.
    BMJ OPEN, 2015, 5 (09):
  • [32] Intramedullary nailing of proximal tibia fractures-An anatomical study comparing three lateral starting points for nail insertion
    Weninger, Patrick
    Tschabitscher, Manfred
    Traxler, Hannes
    Pfafl, Veronika
    Hertz, Harald
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (02): : 220 - 225
  • [33] Is the contralateral tibia a reliable template for reconstruction: a three-dimensional anatomy cadaveric study
    Pascal Schenk
    Lazaros Vlachopoulos
    Andreas Hingsammer
    Sandro F. Fucentese
    Philipp Fürnstahl
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 2324 - 2331
  • [34] Is the contralateral tibia a reliable template for reconstruction: a three-dimensional anatomy cadaveric study
    Schenk, Pascal
    Vlachopoulos, Lazaros
    Hingsammer, Andreas
    Fucentese, Sandro F.
    Furnstahl, Philipp
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (08) : 2324 - 2331
  • [35] Geometric properties of the fractured tibia stabilized by unreamed interlocking nail: Development of a three-dimensional finite element model
    Raunest, J
    Kynast, W
    Lesch, V
    Kukulies, U
    Hacklander, T
    Schwarting, KH
    Arnold, G
    COMPUTERS AND BIOMEDICAL RESEARCH, 1996, 29 (04): : 259 - 270
  • [36] An Approach to Intraoperatively Identify the Coronal Plane Deformities of the Distal Tibia When Treating Tibial Fractures with Intramedullary Nail Fixation: a Retrospective Study
    Lu, Yao
    Yang, Jie
    Xu, Yibo
    Ma, Teng
    Li, Ming
    Ren, Cheng
    Huang, Qiang
    Zhang, Congming
    Wang, Qian
    Li, Zhong
    Zhang, Kun
    ORTHOPAEDIC SURGERY, 2022, 14 (02) : 365 - 373
  • [37] Efficacy comparison between intramedullary nail fixation and plate fixation in distal tibia fractures: a meta-analysis of randomized controlled trials
    Li, Xiaobin
    Chen, Kaipeng
    Xue, Haipeng
    Cheng, Junwen
    Yu, Xiaoping
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [38] The locked flexible intramedullary humerus nail in pediatric femur and tibia shaft fractures - A feasibility study
    Bienkowski, P
    Harvey, EJ
    Reindl, R
    Berry, GK
    Benaroch, TE
    Ouellet, JA
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2004, 24 (06) : 634 - 637
  • [39] A STUDY ON INTERNAL FIXATION OF COMPOUND FRACTURES OF TIBIA USING INTERLOCKING NAIL WITHOUT REAMING
    Chandra, C. Pradeep
    Rao, K. Chandra Sekhar
    Reddy, A. Krishna
    Srinivas, Bachu
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (45): : 2897 - 2900
  • [40] Native tibia valga: a potential source of varus malreduction during intramedullary tibial nail fixation of tibial shaft fractures
    Tucker, Nicholas J.
    Hadeed, Michael M.
    Mauffrey, Cyril
    Parry, Joshua A.
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (05) : 1165 - 1173