Implications of three-dimensional modeling of tibia for intramedullary nail fixation: A virtual study on Asian cadaver tibia

被引:6
|
作者
Byun, Seong-Eun [1 ]
Jung, Gu-Hee [2 ]
机构
[1] CHA Univ, CHA Bundang Med Ctr, Dept Orthopaed Surg, Pochon, South Korea
[2] Gyeongsang Natl Univ, Dept Orthopaed Surg, Coll Med, Changwon Hosp, 1 Samjeongja Ro, Changwon Si 51472, Gyeongsangnam D, South Korea
关键词
Tibia; Fracture; Intramedullary nail; Three-dimensional modeling; Entry point; INSERTION POINT; TORSION;
D O I
10.1016/j.injury.2019.10.070
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: To determine the optimal entry point (EP) of intramedullary nail (IMN) fixation and introduce a consistent landmark for practical application by analyzing three-dimensional (3D) modeling and virtual implantation. Materials and methods: A total of 104 cadaveric femurs (50 males and 54 females) underwent continuous 1.0 mm slice computed tomography (CT) scans. CT images were imported into Mimics (R) software to reconstruct 3D model of tibiofibular bone with medullary canal. Expert Tibial Nail (ETN (R), empty set12mm/Length 315 mm) was processed into a 3D model at the actual size and optimally implanted in the tibia. After IMN was aligned in a neutral position, it was defined as a true AP projection. In the true AP projection, optimal EP and relationship with adjacent structures were assessed based on the degree of tibial rotation. Results: EP was placed eccentrically around the lateral tibial spine in cephalad view and in true AP projection in all models. In true AP projection, the overlapping point between fibular tip and cortical margin of lateral condyle was placed lateral to the fibular tip in 62 models, and exactly matched with fibular tip in 42 models. As tibia rotates, the position of EP in the AP view changes. When tibia was externally rotated, EP was located to the lateral, not the medial side of the lateraltibialspine. The obliquity of guide wire also changed withtibialrotation; the obliquity of guide wire aligned in a straight in true AP projection. Conclusion: Optimal determination of EP and guide wire direction should be performed by considering the overlapping point that should be placed to just or lateral side of fibular tip in AP projection. Compared with fibular bisector line, the overlapping point is also useful as a practical landmark for making true AP projection and determining optimal EP. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:505 / 509
页数:5
相关论文
共 50 条
  • [21] Three-Dimensional Finite Element Analysis and Comparison of a New Intramedullary Fixation with Interlocking Intramedullary Nail
    Chang-cheng Liu
    Wen-zhao Xing
    Ya-xing Zhang
    Zheng-hua Pan
    Wen-ling Feng
    Cell Biochemistry and Biophysics, 2015, 71 : 717 - 724
  • [22] Does Intramedullary Nail Fixation of the Tibia Pose the Same Risk of Pulmonary Complications as Intramedullary Nail Fixation of the Femur? A Propensity Score-Matched Analysis
    Wheatley, Benjamin M.
    O'Hara, Nathan N.
    Coale, Max
    O'Toole, Robert V.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (02) : E45 - E50
  • [23] Outcomes following combined intramedullary nail and plate fixation for complex tibia fractures: A multi-centre study
    Yoon, Richard S.
    Bible, Jesse
    Marcus, Matthew S.
    Donegan, Derek J.
    Bergmann, Karl A.
    Siebler, Justin C.
    Mir, Hassan R.
    Liporace, Frank A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (06): : 1097 - 1101
  • [24] Randomized, Prospective Comparison of Plate versus Intramedullary Nail Fixation for Distal Tibia Shaft Fractures
    Vallier, Heather A.
    Cureton, Beth Ann
    Patterson, Brendan M.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (12) : 736 - 741
  • [25] Intramedullary nail fixation versus locking plate fixation for adults with a fracture of the distal tibia: the UK FixDT RCT
    Costa, Matthew L.
    Achten, Juul
    Hennings, Susie
    Boota, Nafisa
    Griffin, James
    Petrou, Stavros
    Maredza, Mandy
    Dritsaki, Melina
    Wood, Thomas
    Masters, James
    Pallister, Ian
    Lamb, Sarah E.
    Parsons, Nick R.
    HEALTH TECHNOLOGY ASSESSMENT, 2018, 22 (25) : 1 - +
  • [26] A STUDY OF EXCHANGE OF FAILED IMPLANT WITH INTRAMEDULLARY INTERLOCKING NAIL IN FRACTURES OF FEMUR AND TIBIA
    Radhakrishna, Rapaka
    Lakkireddy, Maheshwar
    Naveen, Gouru
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (74): : 12920 - 12927
  • [27] Early results of intramedullary nail fixation in distal tibia oblique osteotomy for the reduction of soft tissue complications
    Morohashi, Itaru
    Mogami, Atsuhiko
    Wakeshima, Tomoko
    Kameda, So
    Matsuo, Tomoji
    Muraoka, Tatsuhiko
    Obayashi, Osamu
    Kaneko, Kazuo
    Ishijima, Muneaki
    JOURNAL OF ORTHOPAEDIC SURGERY, 2023, 31 (01)
  • [28] Three-dimensional simulation of fracture repair in the human tibia
    Lacroix, D.
    Prendergast, P.J.
    Computer Methods in Biomechanics and Biomedical Engineering, 2002, 5 (05) : 369 - 376
  • [29] Rethinking the Coronal Anatomic Axis of the Distal Tibia for Intramedullary Nail Placement: A Cadaveric Study
    Aneja, Arun
    Marquez-Lara, Alejandro
    Luo, T. David
    Teasdall, Robert J.
    Isla, Alexander
    Albano, Ashley
    Halvorson, Jason J.
    Carroll, Eben A.
    HSS JOURNAL, 2022, 18 (02) : 284 - 289
  • [30] Improved intra-operative reduction control using a three-dimensional mobile image intensifier - A proximal tibia cadaver study
    Goesling, T.
    Klingler, K.
    Geerling, J.
    Shin, H.
    Fehr, M.
    Krettek, C.
    Huefner, T.
    KNEE, 2009, 16 (01): : 58 - 63