Design and performance evaluation of high resolution small animal PET scanner based on monolithic crystal: a simulation study

被引:11
|
作者
Sanaat, A. [1 ,2 ]
Zafarghandi, M. S. [1 ]
Ay, M. R. [2 ,3 ]
机构
[1] Amirkabir Univ Technol, Fac Nucl Engn & Phys, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Models and simulations; MONTE-CARLO SIMULATIONS; OPTICAL-SIMULATION; CONTINUOUS LSO; DETECTOR; GATE; IMPLEMENTATION; ARRAY;
D O I
10.1088/1748-0221/14/01/P01005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Dedicated small-animal PET scanners functionality can be optimized by improving the sensitivity and spatial resolution of the scanner. Approximately most of the developed and commercially available small-animal PET scanners are equipped with pixelated scintillators; therefore, their spatial resolution is limited to the crystal pixel size. Complex fabrication, low-sensitivity, and disability in depth of interaction calculation (DOI) are the major disadvantages of pixelated crystals. However, monolithic scintillator crystals are known as one of the most commonly used substitutions, as they have higher sensitivity, DOI recognition, and lower cost. We already designed and implemented a dedicated small-animal PET scanner based on pixelated scintillator crystals and silicon photomultiplier (SiPM). In this study, we plan to present a new optimized design based on the monolithic crystal, with similar performance by the previous scanner. Then we would optimize the thickness of the monolithic crystals for animal PET scanners as a function of sensitivity and spatial resolution. All simulations were performed based on GEANT4, a validated Monte Carlo toolkit. We simulated a recently fabricated scanner with pixelated crystals and compared it with a simulated scanner based on an optimized monolithic crystal. The experimental setup used for comparison and validation is a small Animal PET consisting of ten pixelated modules. This study anticipates that by replacing a pixelated crystal (consist of 24 x 24 LYSO elements, and 2 x 2 x 10 mm(3) crystal size) with a monolithic crystal (with 8 mm thickness and 50.2 x 50.2 entrance area), the average spatial resolution stays the same and sensitivity grows similar to 17% in the center of AFOV and also the fabrication cost dives remarkably. Simulation reveals that although the depth of interaction DOI was not taken into consideration, the crystals with 6 mm thickness have acceptable spatial resolution (similar to 1.3 mm FWHM at the centre of the AFOV) and relatively good absolute sensitivity (similar to 1.6%).
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Performance simulation of high resolution and high sensitivity Prism-PET brain scanner
    Petersen, Eric
    Neilson, Peter
    LaBella, Andy
    Howanskvi, Adrian
    Cao, Xinjie
    Wang, Zipai
    Woody, Craig
    Biegon, Anat
    Rahmim, Arman
    Zhao, Wei
    Goldan, Amir
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [42] Simulation Study of Sensitivity and Resolution for a Small Animal PET Ring Based on Continuous Crystals
    Etxebeste, A.
    Barrio, J.
    Lacasta, C.
    Llosa, G.
    Munoz, E.
    Solaz, C.
    Solevi, P.
    Oliver, J. F.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [43] Micropet II - Design of a 1 mm resolution pet scanner for small animal imaging.
    Cherry, SR
    Shao, Y
    Slates, RB
    Wilcut, E
    Chatziioannou, AF
    Dahlbom, M
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 75P - 75P
  • [44] Performance of a small animal PET scanner based on photosensitive wire chambers.
    Bruyndonckx, P
    Liu, X
    Tavernier, S
    Zhang, SP
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1335 - 1338
  • [45] Performance of an Ultralow-Dose High-Resolution Pediatric TOF-PET Scanner Based on Monolithic Scintillators
    Mikhaylova, E.
    Tabacchini, V.
    Borghi, G.
    Vogel, W.
    Mollet, P.
    D'Hoe, E.
    Schaart, D.
    Vandenberghe, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S437 - S437
  • [46] Performance evaluation of a high-sensitivity large-aperture small-animal PET scanner: ClairvivoPET
    Tetsuro Mizuta
    Keishi Kitamura
    Hiroshi Iwata
    Yoshiyuki Yamagishi
    Atsushi Ohtani
    Kazumi Tanaka
    Yoshihiro Inoue
    Annals of Nuclear Medicine, 2008, 22 : 447 - 455
  • [47] Performance evaluation of a high-sensitivity large-aperture small-animal PET scanner: ClairvivoPET
    Mizuta, Tetsuro
    Kitamura, Keishi
    Iwata, Hiroshi
    Yamagishi, Yoshiyuki
    Ohtani, Atsushi
    Tanaka, Kazumi
    Inoue, Yoshihiro
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (05) : 447 - 455
  • [48] Performance evaluation of the 32-module quadHIDAC small-animal PET scanner
    Schäfers, KP
    Reader, AJ
    Kriens, M
    Knoess, C
    Schober, O
    Schäfers, M
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (06) : 996 - 1004
  • [49] The ClearPET™:: A high resolution high sensitivity dual-layer phoswich small animal PET scanner
    Heinrichs, U
    Bruyndonckx, P
    Choi, Y
    Dietzel, G
    Korjik, M
    Lecoq, P
    Morel, C
    Pedrini, C
    Petrosyan, AG
    Pietrzyk, U
    Sappey-Marinier, D
    Streun, M
    Tavernier, S
    Ziemons, K
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S400 - S400
  • [50] SiliPET: An ultra-high resolution design of a small animal PET scanner based on stacks of double-sided silicon strip detector
    Di Domenico, Giovanni
    Zavattini, Guido
    Cesca, Nicola
    Auricchio, Natalia
    Andritschke, Robert
    Schopper, Florian
    Kanbach, Gottfried
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 22 - 25