Design and performance evaluation of high resolution small animal PET scanner based on monolithic crystal: a simulation study

被引:11
|
作者
Sanaat, A. [1 ,2 ]
Zafarghandi, M. S. [1 ]
Ay, M. R. [2 ,3 ]
机构
[1] Amirkabir Univ Technol, Fac Nucl Engn & Phys, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Models and simulations; MONTE-CARLO SIMULATIONS; OPTICAL-SIMULATION; CONTINUOUS LSO; DETECTOR; GATE; IMPLEMENTATION; ARRAY;
D O I
10.1088/1748-0221/14/01/P01005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Dedicated small-animal PET scanners functionality can be optimized by improving the sensitivity and spatial resolution of the scanner. Approximately most of the developed and commercially available small-animal PET scanners are equipped with pixelated scintillators; therefore, their spatial resolution is limited to the crystal pixel size. Complex fabrication, low-sensitivity, and disability in depth of interaction calculation (DOI) are the major disadvantages of pixelated crystals. However, monolithic scintillator crystals are known as one of the most commonly used substitutions, as they have higher sensitivity, DOI recognition, and lower cost. We already designed and implemented a dedicated small-animal PET scanner based on pixelated scintillator crystals and silicon photomultiplier (SiPM). In this study, we plan to present a new optimized design based on the monolithic crystal, with similar performance by the previous scanner. Then we would optimize the thickness of the monolithic crystals for animal PET scanners as a function of sensitivity and spatial resolution. All simulations were performed based on GEANT4, a validated Monte Carlo toolkit. We simulated a recently fabricated scanner with pixelated crystals and compared it with a simulated scanner based on an optimized monolithic crystal. The experimental setup used for comparison and validation is a small Animal PET consisting of ten pixelated modules. This study anticipates that by replacing a pixelated crystal (consist of 24 x 24 LYSO elements, and 2 x 2 x 10 mm(3) crystal size) with a monolithic crystal (with 8 mm thickness and 50.2 x 50.2 entrance area), the average spatial resolution stays the same and sensitivity grows similar to 17% in the center of AFOV and also the fabrication cost dives remarkably. Simulation reveals that although the depth of interaction DOI was not taken into consideration, the crystals with 6 mm thickness have acceptable spatial resolution (similar to 1.3 mm FWHM at the centre of the AFOV) and relatively good absolute sensitivity (similar to 1.6%).
引用
收藏
页数:16
相关论文
共 50 条
  • [31] A small animal PET scanner with millimeter spatial resolution.
    Del Guerra, A
    Di Domenico, G
    Scandola, M
    Zavattini, G
    Giganti, M
    Uccelli, L
    Piffanelli, A
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 133P - 133P
  • [32] Initial evaluation of the Indiana small animal PET scanner
    Rouze, Ned C.
    Soon, Victor C.
    Young, John W.
    Siegel, Stefan
    Hutchins, Gary D.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2394 - 2398
  • [33] Performance evaluation of a small field of view (FOV) high sensitivity high spatial resolution PET scanner.
    Hutchins, GD
    Simon, AJ
    Winkle, W
    Carlson, K
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 333 - 333
  • [34] Imaging Performance of the MOLECUBES β-CUBE - a dedicated small animal PET scanner using monolithic LYSO scintillator
    Krishnamoorthy, S.
    Blankemeyer, E.
    Mollet, P.
    Surti, S.
    Holen, R. V.
    Karp, J. S.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [35] Performance characterization of a high-sensitivity small-animal PET scanner
    Kao, Chien-Min
    Xie, Qingguo
    Dong, Yun
    Wan, Lu
    Chen, Chin-Tu
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4176 - +
  • [36] Preliminary studies on the design and simulation of high resolution small animal PET scanners with octagonal geometry
    Ortuño, JE
    Vaquero, JJ
    Kontaxakis, G
    Desco, M
    Santos, A
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2053 - 2057
  • [37] Design and performance evaluation of a high-resolution small animal positron tomograph
    Pavlopoulos, S
    Tzanakos, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) : 3249 - 3255
  • [38] MicroPET I: Performance evaluation of a very high resolution PET scanner for imaging small animals.
    Chatziioannou, A
    Cherry, SR
    Shao, Y
    Silverman, RW
    Meadors, K
    Farquhar, T
    Phelps, ME
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 19 - 19
  • [39] Preliminary evaluation of a monolithic detector module for integrated PET/MRI scanner with high spatial resolution
    Pani, R.
    Gonzalez, A. J.
    Bettiol, M.
    Fabbri, A.
    Cinti, M. N.
    Preziosi, E.
    Borrazzo, C.
    Conde, P.
    Pellegrini, R.
    Di Castro, E.
    Majewski, S.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [40] Design and performance of SIAT aPET: a uniform high-resolution small animal PET scanner using dual-ended readout detectors
    Kuang, Zhonghua
    Wang, Xiaohui
    Ren, Ning
    Wu, San
    Gao, Juan
    Zeng, Tianyi
    Gao, Dongfang
    Zhang, Chunhui
    Sang, Ziru
    Hu, Zhanli
    Du, Junwei
    Liang, Dong
    Liu, Xin
    Zheng, Hairong
    Yang, Yongfeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23):