Design and performance evaluation of high resolution small animal PET scanner based on monolithic crystal: a simulation study

被引:11
|
作者
Sanaat, A. [1 ,2 ]
Zafarghandi, M. S. [1 ]
Ay, M. R. [2 ,3 ]
机构
[1] Amirkabir Univ Technol, Fac Nucl Engn & Phys, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Models and simulations; MONTE-CARLO SIMULATIONS; OPTICAL-SIMULATION; CONTINUOUS LSO; DETECTOR; GATE; IMPLEMENTATION; ARRAY;
D O I
10.1088/1748-0221/14/01/P01005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Dedicated small-animal PET scanners functionality can be optimized by improving the sensitivity and spatial resolution of the scanner. Approximately most of the developed and commercially available small-animal PET scanners are equipped with pixelated scintillators; therefore, their spatial resolution is limited to the crystal pixel size. Complex fabrication, low-sensitivity, and disability in depth of interaction calculation (DOI) are the major disadvantages of pixelated crystals. However, monolithic scintillator crystals are known as one of the most commonly used substitutions, as they have higher sensitivity, DOI recognition, and lower cost. We already designed and implemented a dedicated small-animal PET scanner based on pixelated scintillator crystals and silicon photomultiplier (SiPM). In this study, we plan to present a new optimized design based on the monolithic crystal, with similar performance by the previous scanner. Then we would optimize the thickness of the monolithic crystals for animal PET scanners as a function of sensitivity and spatial resolution. All simulations were performed based on GEANT4, a validated Monte Carlo toolkit. We simulated a recently fabricated scanner with pixelated crystals and compared it with a simulated scanner based on an optimized monolithic crystal. The experimental setup used for comparison and validation is a small Animal PET consisting of ten pixelated modules. This study anticipates that by replacing a pixelated crystal (consist of 24 x 24 LYSO elements, and 2 x 2 x 10 mm(3) crystal size) with a monolithic crystal (with 8 mm thickness and 50.2 x 50.2 entrance area), the average spatial resolution stays the same and sensitivity grows similar to 17% in the center of AFOV and also the fabrication cost dives remarkably. Simulation reveals that although the depth of interaction DOI was not taken into consideration, the crystals with 6 mm thickness have acceptable spatial resolution (similar to 1.3 mm FWHM at the centre of the AFOV) and relatively good absolute sensitivity (similar to 1.6%).
引用
收藏
页数:16
相关论文
共 50 条
  • [21] SiliPET: An ultra high resolution design of a small animal PET scanner based on double sided silicon strip detector stacks
    Zavattini, G.
    Cesca, N.
    Di Domenico, G.
    Moretti, E.
    Sabba, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01): : 393 - 397
  • [22] SiliPET: Design of an ultra-high resolution small animal PET scanner based on stacks of semi-conductor detectors
    Cesca, N.
    Auricchio, N.
    Di Domenico, G.
    Zavattini, G.
    Malaguti, R.
    Andritschke, R.
    Kanbach, G.
    Schopper, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01): : 225 - 227
  • [23] Design study for the ClearPET/XPAD small animal PET/CT scanner
    Khodaverdi, M.
    Nicol, S.
    Loess, J.
    Brunner, F. Cassol
    Karkar, S.
    Morel, C.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4300 - 4302
  • [24] Design of a very high-resolution small animal PET scanner using a silicon scatter detector insert
    Park, Sang-June
    Rogers, W. Leslie
    Clinthorne, Neal H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4653 - 4677
  • [25] Quantitative evaluation of the combined YAP-(S)PET II scanner with a high resolution small animal CT
    Bartoli, A.
    Belcari, N.
    Fabbri, S.
    Panetta, D.
    Moehrs, S.
    Del Guerra, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S194 - S194
  • [26] H2RSPET: a 0.5 mm resolution high-sensitivity small-animal PET scanner, a simulation study
    Lai, Youfang
    Wang, Qian
    Zhou, Shiwei
    Xie, Zhaoheng
    Qi, Jinyi
    Cherry, Simon R.
    Jin, Mingwu
    Chi, Yujie
    Du, Junwei
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06):
  • [27] Performance evaluation of a small animal PET scanner a high level of multiplexing and charge-signal transmission
    Lee, Sangwon
    Choi, Yong
    Jung, Jin Ho
    Jung, Jiwoong
    Kim, kyu Bom
    Choe, Hyeok-jun
    Leem, Hyun Tae
    Lee, Hwunjae
    Huh, Yong-Min
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (04):
  • [28] Design of a small animal MR compatible PET scanner
    Slates, R
    Cherry, S
    Boutefnouchet, A
    Shao, YP
    Dahlbom, M
    Farahani, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 565 - 570
  • [29] Design of a small animal MR compatible PET scanner
    UCLA Sch of Medicine, Los Angeles, United States
    IEEE Trans Nucl Sci, 3 II (565-570):
  • [30] Design of a small animal MR compatible PET scanner
    Slates, Randal
    Cherry, Simon
    Boutefnouchet, Abdel
    Shao, Yiping
    Dahlbom, Magnus
    Farahani, Keyvan
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 2 : 1268 - 1273