Fractal signature and lacunarity in the measurement of the texture of trabecular bone in clinical CT images

被引:71
|
作者
Dougherty, G
Henebry, GM
机构
[1] Kuwait Univ, Fac Allied Hlth Sci, Dept Radiol Sci, Sulibikhat, Kuwait
[2] Univ Nebraska, Ctr Adv Land Management Informat Technol, Lincoln, NE 68588 USA
关键词
texture; fractal dimension; fractal signature; lacunarity; bone architecture;
D O I
10.1016/S1350-4533(01)00057-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fractal analysis is a method of characterizing complex shapes such as the trabecular structure of bone. Numerous algorithms for estimating fractal dimension have been described, but the Fourier power spectrum method is particularly applicable to self-affine fractals, and facilitates corrections for the effects of noise and blurring in an image. We found that it provided accurate estimates of fractal dimension for synthesized fractal images. For natural texture images fractality is limited to a range of scales, and the fractal dimension as a function of spatial frequency presents as a fractal signature. We found that the fractal signature was more successful at discriminating between these textures than either the global fractal dimension or other metrics such as the mean width and root-mean-square width of the spectral density plots. Different natural textures were also readily distinguishable using lacunarity plots, which explicitly characterize the average size and spatial organization of structural sub-units within an image. The fractal signatures of small regions of interest (32x32 pixels), computed in the frequency domain after corrections for imaging system noise and MTF, were able to characterize the texture of vertebral trabecular bone in CT images. Even small differences in texture due to acquisition slice thickness resulted in measurably different fractal signatures. These differences were also readily apparent in lacunarity plots, which indicated that a slice thickness of I turn or less is necessary if essential architectural information is not to be lost. Since lacunarity measures gap size and is not predicated on fractality, it may be particularly useful for characterizing the texture of trabecular bone. (C) 2001 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:369 / 380
页数:12
相关论文
共 50 条
  • [41] Fractal dimension and lacunarity of tumor microscopic images as prognostic indicators of clinical outcome in early breast cancer
    Pribic, Jelena
    Vasiljevic, Jelena
    Kanjer, Ksenija
    Konstantinovic, Zora Neskovic
    Milosevic, Nebojsa T.
    Vukosavljevic, Dragica Nikolic
    Radulovic, Marko
    BIOMARKERS IN MEDICINE, 2015, 9 (12) : 1279 - 1290
  • [42] The effects of projection geometry and trabecular texture on estimated fractal dimensions in two alveolar bone models
    Chen, SK
    Chen, CM
    DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (05) : 270 - 274
  • [43] Fractal analysis of bone texture on os calcis radiographs compared with trabecular microarchitecture analyzed by histomorphometry
    Lespessailles, E
    Roux, JP
    Benhamou, CL
    Arlot, ME
    Eynard, E
    Harba, R
    Padonou, C
    Meunier, PJ
    CALCIFIED TISSUE INTERNATIONAL, 1998, 63 (02) : 121 - 125
  • [44] Fractal analysis of radiographic trabecular bone texture can improve the fracture risk evaluation.
    Benhamou, C
    Poupon, S
    Pothuaud, L
    Jennane, R
    Lespessailles, E
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 : S402 - S402
  • [45] Differences in trabecular bone texture between knees with and without radiographic osteoarthritis detected by fractal methods
    Podsiadlo, P.
    Dahl, L.
    Englund, M.
    Lohmander, L. S.
    Stachowiak, G. W.
    OSTEOARTHRITIS AND CARTILAGE, 2008, 16 (03) : 323 - 329
  • [46] Trabecular Bone Texture from Clinical MRI Scans Reflects Biomechanical Properties of Bone
    Dash, Alexander
    Breighner, Ryan
    Gonzalez, Fernando Quevedo
    Koff, Matthew
    Blumberg, Olivia
    Heilbronner, Alison
    Billings, Emma
    Cunningham, Matthew
    Kim, Han Jo
    Nieves, Jeri
    Stein, Emily
    JOURNAL OF BONE AND MINERAL RESEARCH, 2023, 38 : 396 - 396
  • [47] Fractal Analysis of Bone Texture on Os Calcis Radiographs Compared with Trabecular Microarchitecture Analyzed by Histomorphometry
    E. Lespessailles
    J. P. Roux
    C. L. Benhamou
    M. E. Arlot
    E. Eynard
    R. Harba
    C. Padonou
    P. J. Meunier
    Calcified Tissue International, 1998, 63 : 121 - 125
  • [48] Skeletal dosimetry based on μCT images of trabecular bone: update and comparisons
    Kramer, R.
    Cassola, V. F.
    Vieira, J. W.
    Khoury, H. J.
    de Oliveira Lira, C. A. B.
    Brown, K. Robson
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12): : 3995 - 4021
  • [49] TEXTURE CORRELATION - A METHOD FOR THE MEASUREMENT OF DETAILED STRAIN DISTRIBUTIONS WITHIN TRABECULAR BONE
    BAY, BK
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (02) : 258 - 267
  • [50] Texture appearance characterization of pre-sliced pork ham images using fractal metrics: Fourier analysis dimension and lacunarity
    Valous, Nektarios A.
    Mendoza, Fernando
    Sun, Da-Wen
    Allen, Paul
    FOOD RESEARCH INTERNATIONAL, 2009, 42 (03) : 353 - 362