Fractal signature and lacunarity in the measurement of the texture of trabecular bone in clinical CT images

被引:71
|
作者
Dougherty, G
Henebry, GM
机构
[1] Kuwait Univ, Fac Allied Hlth Sci, Dept Radiol Sci, Sulibikhat, Kuwait
[2] Univ Nebraska, Ctr Adv Land Management Informat Technol, Lincoln, NE 68588 USA
关键词
texture; fractal dimension; fractal signature; lacunarity; bone architecture;
D O I
10.1016/S1350-4533(01)00057-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fractal analysis is a method of characterizing complex shapes such as the trabecular structure of bone. Numerous algorithms for estimating fractal dimension have been described, but the Fourier power spectrum method is particularly applicable to self-affine fractals, and facilitates corrections for the effects of noise and blurring in an image. We found that it provided accurate estimates of fractal dimension for synthesized fractal images. For natural texture images fractality is limited to a range of scales, and the fractal dimension as a function of spatial frequency presents as a fractal signature. We found that the fractal signature was more successful at discriminating between these textures than either the global fractal dimension or other metrics such as the mean width and root-mean-square width of the spectral density plots. Different natural textures were also readily distinguishable using lacunarity plots, which explicitly characterize the average size and spatial organization of structural sub-units within an image. The fractal signatures of small regions of interest (32x32 pixels), computed in the frequency domain after corrections for imaging system noise and MTF, were able to characterize the texture of vertebral trabecular bone in CT images. Even small differences in texture due to acquisition slice thickness resulted in measurably different fractal signatures. These differences were also readily apparent in lacunarity plots, which indicated that a slice thickness of I turn or less is necessary if essential architectural information is not to be lost. Since lacunarity measures gap size and is not predicated on fractality, it may be particularly useful for characterizing the texture of trabecular bone. (C) 2001 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:369 / 380
页数:12
相关论文
共 50 条
  • [21] TRABECULAR TEXTURE ANALYSIS OF CT IMAGES IN THE RELATIONSHIP WITH SPINAL FRACTURE
    ITO, M
    OHKI, M
    HAYASHI, K
    YAMADA, M
    UETANI, M
    NAKAMURA, T
    RADIOLOGY, 1995, 194 (01) : 55 - 59
  • [22] Fractal lacunarity of trabecular bone and magnetic resonance imaging: New perspectives for osteoporotic fracture risk assessment
    Zaia, Annamaria
    WORLD JOURNAL OF ORTHOPEDICS, 2015, 6 (02): : 221 - 235
  • [23] Fractal dimension, lacunarity and succolarity analyses on CT images of reservoir rocks for permeability prediction
    Xia, Yuxuan
    Cai, Jianchao
    Perfect, Edmund
    Wei, Wei
    Zhang, Qi
    Meng, Qingbang
    JOURNAL OF HYDROLOGY, 2019, 579
  • [24] Fractal Analysis of Trabecular Bone Texture on Radiographs: Discriminant Value in Postmenopausal Osteoporosis
    L. Pothuaud
    E. Lespessailles
    R. Harba
    R. Jennane
    V. Royant
    E. Eynard
    C. L. Benhamou
    Osteoporosis International, 1998, 8 : 618 - 626
  • [25] Fractal analysis of trabecular bone texture on radiographs: Discriminant value in postmenopausal osteoporosis
    Pothuaud, L
    Lespessailles, E
    Harba, R
    Jennane, R
    Royant, V
    Eynard, E
    Benhamou, CL
    OSTEOPOROSIS INTERNATIONAL, 1998, 8 (06) : 618 - 625
  • [26] Fractal analysis of trabecular bone texture on radiographs: Effects of age on microarchitectural changes
    Benhamou, CL
    Poupon, S
    Pothuaud, L
    Niamane, R
    Harba, R
    Lespessailles, E
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : S132 - S133
  • [27] DETERMINATION OF FRACTAL SCALES ON TRABECULAR BONE X-RAY IMAGES
    Harba, R.
    Jacquet, G.
    Jennane, R.
    Loussot, T.
    Benhamou, C. L.
    Lespessailles, E.
    Tourliere, D.
    FRACTALS-COMPLEX GEOMETRY PATTERNS AND SCALING IN NATURE AND SOCIETY, 1994, 2 (03) : 451 - 456
  • [28] Relationship between trabecular texture features of CT images and an amount of bone cement volume injection in percutaneous vertebroplasty
    Tack, GR
    Choi, HG
    Shin, KC
    Lee, SJ
    MEDICAL IMAGING 2001: IMAGE PERCEPTION AND PERFORMANCE, 2001, 4324 : 227 - 233
  • [29] Fractal Signature Vectors and Lacunarity Class Distance Matrices to extract new adaptive texture features from cell nuclei
    Nielsen, B
    Albregtsen, F
    Danielsen, HE
    FRACTALS IN BIOLOGY AND MEDICINE, VOL III, 2002, : 55 - 65
  • [30] Analysis of trabecular bone using site-specific fractal values calculated from cone beam CT images
    Gaalaas, Laurence
    Henn, Lisa
    Gaillard, Philippe R.
    Ahmad, Mansur
    Islam, Mohammad Saiful
    ORAL RADIOLOGY, 2014, 30 (02) : 179 - 185