Fractal signature and lacunarity in the measurement of the texture of trabecular bone in clinical CT images

被引:71
|
作者
Dougherty, G
Henebry, GM
机构
[1] Kuwait Univ, Fac Allied Hlth Sci, Dept Radiol Sci, Sulibikhat, Kuwait
[2] Univ Nebraska, Ctr Adv Land Management Informat Technol, Lincoln, NE 68588 USA
关键词
texture; fractal dimension; fractal signature; lacunarity; bone architecture;
D O I
10.1016/S1350-4533(01)00057-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fractal analysis is a method of characterizing complex shapes such as the trabecular structure of bone. Numerous algorithms for estimating fractal dimension have been described, but the Fourier power spectrum method is particularly applicable to self-affine fractals, and facilitates corrections for the effects of noise and blurring in an image. We found that it provided accurate estimates of fractal dimension for synthesized fractal images. For natural texture images fractality is limited to a range of scales, and the fractal dimension as a function of spatial frequency presents as a fractal signature. We found that the fractal signature was more successful at discriminating between these textures than either the global fractal dimension or other metrics such as the mean width and root-mean-square width of the spectral density plots. Different natural textures were also readily distinguishable using lacunarity plots, which explicitly characterize the average size and spatial organization of structural sub-units within an image. The fractal signatures of small regions of interest (32x32 pixels), computed in the frequency domain after corrections for imaging system noise and MTF, were able to characterize the texture of vertebral trabecular bone in CT images. Even small differences in texture due to acquisition slice thickness resulted in measurably different fractal signatures. These differences were also readily apparent in lacunarity plots, which indicated that a slice thickness of I turn or less is necessary if essential architectural information is not to be lost. Since lacunarity measures gap size and is not predicated on fractality, it may be particularly useful for characterizing the texture of trabecular bone. (C) 2001 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:369 / 380
页数:12
相关论文
共 50 条
  • [31] Analysing μCT images of bone specimen with wavelets and scaling indices:: Which texture measure does better depict the trabecular bone structure?
    Raeth, Christoph W.
    Bauer, Jan
    Mueller, Dirk
    Rummeny, Ernst J.
    Link, Thomas M.
    Majumdar, Sharmila
    Eckstein, Felix
    Monetti, Roberto
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [32] Influence of segmentation on micro-CT images of trabecular bone
    Tassani, S.
    Korfiatis, V.
    Matsopoulos, G. K.
    JOURNAL OF MICROSCOPY, 2014, 256 (02) : 75 - 81
  • [33] Fractal dimension of trabecular bone projection texture is related to three-dimensional microarchitecture
    Pothuaud, L
    Benhamou, CL
    Porion, P
    Lespessailles, E
    Harba, R
    Levitz, P
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (04) : 691 - 699
  • [34] Assessments of trabecular bone density at implant sites on CT images
    Gomes de Oliveira, Rubelisa Candido
    Leles, Claudio Rodrigues
    Normanha, Leonardo Martins
    Lindh, Christina
    Ribeiro-Rotta, Rejane Faria
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (02): : 231 - 238
  • [35] Analysis of trabecular bone using site-specific fractal values calculated from cone beam CT images
    Laurence Gaalaas
    Lisa Henn
    Philippe R. Gaillard
    Mansur Ahmad
    Mohammad Saiful Islam
    Oral Radiology, 2014, 30 : 179 - 185
  • [36] Fractal evaluation of trabecular bone texture from calcaneus radiographs in corticosteroid induced bone changes.
    Lespessailles, E
    Eynard, E
    Royant, V
    Terem, C
    Valverde, D
    Harba, R
    Benhamou, CL
    JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 : T695 - T695
  • [37] Automatic thresholding of micro-CT trabecular bone images
    Zhang, Yongping
    He, Zhongkun
    Fan, Shaojing
    He, Kejia
    Li, Chen
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 23 - +
  • [38] Fractal analysis of trabecular bone texture on calcaneus radiographs discriminant value in osteoporosis.
    Lespessailles, E
    Benhamou, CL
    Mounji, K
    Jacquet, G
    ARTHRITIS AND RHEUMATISM, 1996, 39 (09): : 369 - 369
  • [39] TRABECULAR BONE TEXTURE MEASUREMENT: A REVIEW OF AVAILABLE TECHNIQUES AND OF EMERGING APPLICATIONS
    Chaintreuil, Jean
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 : S358 - S359
  • [40] Assessment of trabecular structure using high resolution CT images and texture analysis
    Link, TM
    Majumdar, S
    Lin, JC
    Augat, P
    Gould, RG
    Newitt, D
    Ouyang, XL
    Lang, TF
    Mathur, A
    Genant, HK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (01) : 15 - 24