Purpose To evaluate the agreement and interchangeability of noncontact devices of ocular response analyzer (ORA) and the Corvis ST in central corneal thickness measurement. Methods In this prospective comparative study, central corneal thickness (CCT) readings of 284 healthy, nonglaucoma subjects, without previous ocular surgery, were measured with ORA and Corvis ST. Only data from right eyes were analyzed. The mean values of CCT measurements by the ORA versus Corvis ST were compared with the paired sample t test. Bland-Altman plots and 95% limits of agreement (95% LOA) were used to assess the agreement between the measurements of the two devices. Results The mean (+/- standard deviation) age of the participants was 28.0 +/- 4.9 years, and 36.6% were male. The mean CCT measurements were 555 +/- 32 mu m by the ORA and 536 +/- 32 mu m with the Corvis ST (P < 0.001). The Pearson correlation coefficient was 0.964 (P < 0.001). The 95% LOA between the ORA and the Corvis ST was 2.2 to 35.9 mu m. Conclusions The ORA measured the CCT up to 35.9 mu m greater than Corvis ST. Therefore, the two devices may not be used interchangeably for measuring CCT.
机构:
WenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
WenZhou Med Univ, Inst Ocular Biomech, Wenzhou 325027, Zhejiang, Peoples R ChinaWenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
Bao, FangJun
Huang, ZiXu
论文数: 0引用数: 0
h-index: 0
机构:
WenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
WenZhou Med Univ, Inst Ocular Biomech, Wenzhou 325027, Zhejiang, Peoples R ChinaWenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
Huang, ZiXu
Huang, JinHai
论文数: 0引用数: 0
h-index: 0
机构:
WenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
WenZhou Med Univ, Inst Ocular Biomech, Wenzhou 325027, Zhejiang, Peoples R ChinaWenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
Huang, JinHai
Wang, JunJie
论文数: 0引用数: 0
h-index: 0
机构:
Univ Liverpool, Sch Engn, Liverpool, Merseyside, EnglandWenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
Wang, JunJie
Deng, ManLi
论文数: 0引用数: 0
h-index: 0
机构:
WenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
WenZhou Med Univ, Inst Ocular Biomech, Wenzhou 325027, Zhejiang, Peoples R ChinaWenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
Deng, ManLi
Li, LinNa
论文数: 0引用数: 0
h-index: 0
机构:
WenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
WenZhou Med Univ, Inst Ocular Biomech, Wenzhou 325027, Zhejiang, Peoples R ChinaWenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
Li, LinNa
Yu, AYong
论文数: 0引用数: 0
h-index: 0
机构:
WenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
WenZhou Med Univ, Inst Ocular Biomech, Wenzhou 325027, Zhejiang, Peoples R ChinaWenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
Yu, AYong
Wang, QinMei
论文数: 0引用数: 0
h-index: 0
机构:
WenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
WenZhou Med Univ, Inst Ocular Biomech, Wenzhou 325027, Zhejiang, Peoples R ChinaWenZhou Med Univ, Affiliated Eye Hosp, Wenzhou 325027, Zhejiang, Peoples R China
机构:
Univ Liverpool, Sch Engn, Brownlow Hill, Liverpool L69 3GH, Merseyside, EnglandUniv Liverpool, Sch Engn, Brownlow Hill, Liverpool L69 3GH, Merseyside, England
Joda, Akram
Abass, Ahmed
论文数: 0引用数: 0
h-index: 0
机构:
Cardiff Univ, Struct Biophys Grp, Sch Optometry & Vis Sci, Cardiff CF10 3AX, S Glam, WalesUniv Liverpool, Sch Engn, Brownlow Hill, Liverpool L69 3GH, Merseyside, England