Crescent artifacts in cone-beam CT

被引:10
|
作者
Giles, William [1 ]
Bowsher, James [1 ]
Li, Hao
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Med Phys Grad Program, Durham, NC 27710 USA
关键词
crescent artifact; cone-beam CT; image reconstruction; COMPUTED-TOMOGRAPHY; SCATTER;
D O I
10.1118/1.3567508
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In image-guided radiation therapy, cone-beam CT has been adopted for three-dimensional target localization in the treatment room. In many of these cone-beam CT images, dark and light crescent artifacts can be seen. This study investigates potential causes of this artifact and a technique for mitigating the crescents. Methods: Three deviations from an ideal geometry were simulated to assess their ability to cause crescent artifacts: Bowtie filter sag, x-ray tube sag, and x-ray tube rotation. The magnitudes of these deviations were estimated by matching shifts in simulated projections to those observed with clinical systems. To correct the artifacts, angle-dependent blank projections were acquired and incorporated into image reconstruction. The degree of artifact reduction was evaluated with varying numbers (1-380) of blank projections. Scanner-acquired phantom and patient studies were conducted to demonstrate the effectiveness of the proposed correction method. Results: All three investigated causes of the crescent artifact introduced similar mismodeling of the acquired projections and similar crescent artifacts. The deviations required for these artifacts were in the range of 0.5-5 mm or 0.1. RMS error is reduced from 8.91 x 10(-4) to 5.25 x 10(-7) for 1-380 blank projections over a 200 scan angle. In the patient and phantom studies, reconstructions that utilized 380 blank projections largely mitigated the crescent artifacts. Conclusions: Small deviations from an ideal geometry can result in crescent artifacts due to steep gradients in the bowtie filter. Angle-dependent blank projections can largely alleviate the artifacts. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3567508]
引用
收藏
页码:2116 / 2121
页数:6
相关论文
共 50 条
  • [41] On the Determination of the Beam Output of a Kilovoltage Cone-Beam CT
    Ding, G.
    Coffey, C.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [42] Cone Artifacts Correction in Iterative Cone Beam CT Reconstruction
    Yan, H.
    Wang, X.
    Bai, T.
    Lu, W.
    Folkerts, M.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2014, 41 (06) : 526 - 526
  • [43] CT Thermometry for Cone-beam CT Guided Ablation
    DeStefano, Zachary
    Abi-Jaoudeh, Nadine
    Li, Ming
    Wood, Bradford J.
    Summers, Ronald M.
    Yao, Jianhua
    MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [44] On cone-beam computed tomography artifacts induced by titanium implants
    Schulze, Ralf Kurt Willy
    Berndt, Dorothea
    d'Hoedt, Bernd
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (01) : 100 - 107
  • [45] Prevalence of Artifacts in Cone-Beam Computed Tomography: A Retrospective Study
    Mahesh, K. P.
    Deshpande, Prasannasrinivas
    Viveka, S.
    JOURNAL OF INDIAN ACADEMY OF ORAL MEDICINE AND RADIOLOGY, 2022, 34 (04) : 428 - 431
  • [46] Early clinical experience on cone-beam CT
    Yumi Makimoto
    Kenji Matsuzaki
    Shusaku Yoshida
    Hiromu Nishitani
    Journal of Digital Imaging, 1998, 11 : 211 - 213
  • [47] Measurements for quality assurance in the cone-beam CT
    Walter, C.
    Wertz, H.
    Steil, V.
    Lohr, F.
    Wenz, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 95 - 96
  • [48] Dentomaxillofacial cone-beam CT for orthodontic assessment
    Farman, AG
    Scarfe, WC
    Hilgers, MJ
    Bida, O
    Moshiri, M
    Sukovic, P
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1187 - 1190
  • [49] Cone-beam CT of the internal carotid artery
    Hyde, DE
    Naik, S
    Habets, DF
    Holdsworth, DW
    MEDICAL IMAGING 2002: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2002, 4681 : 408 - 415
  • [50] Correction of scatter in megavoltage cone-beam CT
    Spies, L
    Ebert, M
    Groh, BA
    Hesse, BM
    Bortfeld, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03): : 821 - 833