Crescent artifacts in cone-beam CT

被引:10
|
作者
Giles, William [1 ]
Bowsher, James [1 ]
Li, Hao
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Med Phys Grad Program, Durham, NC 27710 USA
关键词
crescent artifact; cone-beam CT; image reconstruction; COMPUTED-TOMOGRAPHY; SCATTER;
D O I
10.1118/1.3567508
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In image-guided radiation therapy, cone-beam CT has been adopted for three-dimensional target localization in the treatment room. In many of these cone-beam CT images, dark and light crescent artifacts can be seen. This study investigates potential causes of this artifact and a technique for mitigating the crescents. Methods: Three deviations from an ideal geometry were simulated to assess their ability to cause crescent artifacts: Bowtie filter sag, x-ray tube sag, and x-ray tube rotation. The magnitudes of these deviations were estimated by matching shifts in simulated projections to those observed with clinical systems. To correct the artifacts, angle-dependent blank projections were acquired and incorporated into image reconstruction. The degree of artifact reduction was evaluated with varying numbers (1-380) of blank projections. Scanner-acquired phantom and patient studies were conducted to demonstrate the effectiveness of the proposed correction method. Results: All three investigated causes of the crescent artifact introduced similar mismodeling of the acquired projections and similar crescent artifacts. The deviations required for these artifacts were in the range of 0.5-5 mm or 0.1. RMS error is reduced from 8.91 x 10(-4) to 5.25 x 10(-7) for 1-380 blank projections over a 200 scan angle. In the patient and phantom studies, reconstructions that utilized 380 blank projections largely mitigated the crescent artifacts. Conclusions: Small deviations from an ideal geometry can result in crescent artifacts due to steep gradients in the bowtie filter. Angle-dependent blank projections can largely alleviate the artifacts. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3567508]
引用
收藏
页码:2116 / 2121
页数:6
相关论文
共 50 条
  • [21] Quantitative Evaluation of Metal Artifacts in CT and Cone-Beam CT Images On the Accuracy of Dose Calculation
    Oyewale, S.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3825 - 3825
  • [22] Analysis of scatter artifacts in cone-beam CT due to scattered radiation of metallic objects
    Iuso, Domenico
    Frysch, Robert
    Pfeiffer, Tim
    Rose, Georg
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [23] Ring Artifacts Reduction in Cone-Beam CT Images based on Independent Component Analysis
    Chen, Yen-Wei
    Duan, Guifang
    Fujita, Akinori
    Hirooka, Ken
    Ueno, Yoshihiro
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1687 - +
  • [24] Unsupervised motion artifacts reduction for cone-beam CT via enhanced landmark detection
    Viriyasaranon, Thanaporn
    Ma, Serie
    Thies, Mareike
    Maier, Andreas
    Choi, Jang-Hwan
    EXPERT SYSTEMS WITH APPLICATIONS, 2025, 278
  • [25] Reduction of Beam Hardening Artifacts in Cone-Beam CT Imaging via SMART-RECON Algorithm
    Li, Yinsheng
    Garrett, John
    Chen, Guang-Hong
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [26] Breathing motion in cone-beam CT
    Rit, S.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S119 - S120
  • [27] Towards cone-beam CT thermometry
    Li, Ming
    Abi-Jaoudeh, Nadine
    Kapoor, Ankur
    Kadoury, Samuel
    Xu, Sheng
    Noordhoek, Niels
    Radaelli, Alessandro
    Carelsen, Bart
    Wood, Bradford J.
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [28] Clinical implementation of a cone-beam CT
    Betgen, A
    van Herk, M
    Remeijer, P
    Sonke, JJ
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S158 - S158
  • [29] Flat Detector Cone-Beam CT
    Kachelriess, Marc
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (02): : 91 - 91
  • [30] Cone-beam CT experience in Aarau
    Cossmann, PH
    Stuessi, A
    von Briel, C
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S9 - S9