Crescent artifacts in cone-beam CT

被引:10
|
作者
Giles, William [1 ]
Bowsher, James [1 ]
Li, Hao
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Med Phys Grad Program, Durham, NC 27710 USA
关键词
crescent artifact; cone-beam CT; image reconstruction; COMPUTED-TOMOGRAPHY; SCATTER;
D O I
10.1118/1.3567508
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In image-guided radiation therapy, cone-beam CT has been adopted for three-dimensional target localization in the treatment room. In many of these cone-beam CT images, dark and light crescent artifacts can be seen. This study investigates potential causes of this artifact and a technique for mitigating the crescents. Methods: Three deviations from an ideal geometry were simulated to assess their ability to cause crescent artifacts: Bowtie filter sag, x-ray tube sag, and x-ray tube rotation. The magnitudes of these deviations were estimated by matching shifts in simulated projections to those observed with clinical systems. To correct the artifacts, angle-dependent blank projections were acquired and incorporated into image reconstruction. The degree of artifact reduction was evaluated with varying numbers (1-380) of blank projections. Scanner-acquired phantom and patient studies were conducted to demonstrate the effectiveness of the proposed correction method. Results: All three investigated causes of the crescent artifact introduced similar mismodeling of the acquired projections and similar crescent artifacts. The deviations required for these artifacts were in the range of 0.5-5 mm or 0.1. RMS error is reduced from 8.91 x 10(-4) to 5.25 x 10(-7) for 1-380 blank projections over a 200 scan angle. In the patient and phantom studies, reconstructions that utilized 380 blank projections largely mitigated the crescent artifacts. Conclusions: Small deviations from an ideal geometry can result in crescent artifacts due to steep gradients in the bowtie filter. Angle-dependent blank projections can largely alleviate the artifacts. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3567508]
引用
收藏
页码:2116 / 2121
页数:6
相关论文
共 50 条
  • [31] Cone-beam CT for radiotherapy applications
    Cho, P.S.
    Johnson, R.H.
    Griffin, T.W.
    1863, Institute of Physics Publishing Ltd, Bristol, Engl (40):
  • [32] CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS
    CHO, PS
    JOHNSON, RH
    GRIFFIN, TW
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11): : 1863 - 1883
  • [33] Cone-Beam CT: Vascular Applications
    Angle, John F.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 16 (03) : 144 - 149
  • [34] Analysis of Cone-Beam Artifacts in off-Centered Circular CT for Four Reconstruction Methods
    Valton, S.
    Peyrin, F.
    Sappey-Marinier, D.
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2006, 2006
  • [35] Correction of couch artifacts in KV cone-beam CT from an on-board imaging system
    Ali, I.
    Lovelock, D.
    Kriminski, S.
    Chang, J.
    Amols, H.
    Ali, I.
    MEDICAL PHYSICS, 2006, 33 (06) : 2280 - 2280
  • [36] Reducing metal artifacts between implants in cone-beam CT by adjusting angular position of the subject
    Min, Chang-Ki
    Kim, Kyoung-A
    ORAL RADIOLOGY, 2021, 37 (03) : 385 - 394
  • [37] Dose calculation on megavoltage cone-beam CT images corrected for cupping and missing data artifacts
    Aubry, J.
    Morin, O.
    Faddegon, B.
    Nunna, C.
    Beaulieu, L.
    Pouliot, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2342 - 2342
  • [38] Reducing metal artifacts between implants in cone-beam CT by adjusting angular position of the subject
    Chang-Ki Min
    Kyoung-A Kim
    Oral Radiology, 2021, 37 : 385 - 394
  • [39] Workflow and performance of intraoperative CT, cone-beam CT, and robotic cone-beam CT for spinal navigation in 503 consecutive patients
    Kendlbacher, Paul
    Tkatschenko, Dimitri
    Czabanka, Marcus
    Bayerl, Simon
    Bohner, Georg
    Woitzik, Johannes
    Vajkoczy, Peter
    Hecht, Nils
    NEUROSURGICAL FOCUS, 2022, 52 (01)
  • [40] A Method to Estimate Cone-Beam CT Dose Index and Cone-Beam Dose Length Product
    Kim, S.
    Song, H.
    Samei, E.
    Yin, F.
    Yoshizumi, T.
    MEDICAL PHYSICS, 2010, 37 (06)