Comparative biomechanical compression testing with a new implant for vertebral body replacement

被引:0
|
作者
Knop, C [1 ]
Lange, U [1 ]
Bastian, L [1 ]
Oeser, M [1 ]
Blauth, M [1 ]
机构
[1] Hannover Med Sch, Unfallchirurg Klin, D-30625 Hannover, Germany
来源
UNFALLCHIRURG | 2001年 / 104卷 / 01期
关键词
thoracolumbar spine; vertebral body replacement; titanium implant; compression test; biomechanics; bone mineral density;
D O I
10.1007/s001130050684
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The authors present a new titanium implant for replacement of the vertebral body (Synex(TM)). Possible indications would be fractures or dislocations with destruction of the anterior column, posttraumatic kyphosis as well as tumors in the throracolumbar spine. The construction has to be completed by a stabilizing implant. For best fit and contact to adjacent end-plates Synex(TM) is distractable in situ. The possibility of secondary dislocation or loss of correction should thereby be minimised. Objectives. We performed comparative compression tests with Synex(TM) and MOSS(TM) ("Harms mesh cage") on human cadaveric specimens of intact vertebrae (L1). The aim of the study was to measure the compressive strength of the vertebral body end-plate in uniaxial loading via both implants to exclude a caving of Synex(TM) in vivo. Methods. 12 human cadaveric specimens of intact vertebrae (L1) were divided in 2 similar groups (matched pairs) according to bone mineral density (BMD), determined using DE-QCT. The specimens were loaded with axial compression force at a constant speed of 5 mm/min to failure and the displacement was recorded with a continuous load-displacement curve. Results. The mean ultimate compression force (F-max) showed a tendency towards a higher result testing Synex(TM) with 3396 N versus 2719 N (non significant). The displacement until F-max was 2.9 mm in group 5 (Synex(TM)), which was half as long as in group M (5.8 mm). The difference was significant (p<0.001). The compression force was twice as high and significantly (p<0.05) higher with Synex(TM) at a displacement of 1 mm, 1.5 mm and 2 mm.A significant (p<0.001) correlation (R=0.89) between F-max and BMD was found. Conclusions. Synex(TM) was found to be at least comparable to MOSS(TM) for suspensory replacement of the vertebral body at the thoracolumbar spine. A possible consequence of the significantly higher mean compression forces between 1 and 2 mm displacement might be a decreased segmental deformation or loss of correction.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 50 条
  • [1] Biomechanical compression tests with a new implant for thoracolumbar vertebral body replacement
    Knop, C
    Lange, U
    Bastian, L
    Oeser, M
    Blauth, M
    EUROPEAN SPINE JOURNAL, 2001, 10 (01) : 30 - 37
  • [2] Biomechanical compression tests with a new implant for thoracolumbar vertebral body replacement
    C. Knop
    U. Lange
    L. Bastian
    M. Oeser
    M. Blauth
    European Spine Journal, 2001, 10 : 30 - 37
  • [3] Comparative biomechanical compression testing with a new implant for vertebral body replacement [Vergleichende biomechanische kompressionsversuche mit einem neuen wirbelkörperersatzimplantat]
    Knop C.
    Lange U.
    Bastian L.
    Oeser M.
    Blauth M.
    Der Unfallchirurg, 2001, 104 (1): : 25 - 33
  • [4] A new distractable implant for vertebral body replacement: biomechanical testing of four implants for the thoracolumbar spine
    Reinhold, M.
    Schmoelz, W.
    Canto, F.
    Krappinger, D.
    Blauth, M.
    Knop, Christian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (10) : 1375 - 1382
  • [5] A new distractable implant for vertebral body replacement: biomechanical testing of four implants for the thoracolumbar spine
    M. Reinhold
    W. Schmoelz
    F. Canto
    D. Krappinger
    M. Blauth
    Christian Knop
    Archives of Orthopaedic and Trauma Surgery, 2009, 129 : 1375 - 1382
  • [6] Biomechanical performance of the new BeadEx implant in the treatment of osteoporotic vertebral body compression fractures: Restoration and maintenance of height and stability
    Kettler, A.
    Schmoelz, W.
    Shezifi, Y.
    Ohana, N.
    Ben-Arye, A.
    Claes, L.
    Wilke, H. -J.
    CLINICAL BIOMECHANICS, 2006, 21 (07) : 676 - 682
  • [7] Prospective multicenter study with a new implant for thoracolumbar vertebral body replacement
    Uta Lange
    Christian Knop
    Leonard Bastian
    Michael Blauth
    Archives of Orthopaedic and Trauma Surgery, 2003, 123 : 203 - 208
  • [8] Prospective multicenter study with a new implant for thoracolumbar vertebral body replacement
    Lange, U
    Knop, C
    Bastian, L
    Blauth, M
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2003, 123 (05) : 203 - 208
  • [9] Biomechanical stability with a new implant for vertebral body replacement. 3-dimensional motion analysis on human cadaveric spines
    Knop, C
    Lange, U
    Bastian, L
    Blauth, M
    UNFALLCHIRURG, 2001, 104 (10): : 984 - 997
  • [10] Comparative biomechanical study of a new transpedicular vertebral device and vertebroplasty for the treatment or prevention of vertebral compression fractures
    Aebi, Max
    Maas, Charlene
    von Treuheim, Theodor Di Pauli
    Friedrich, Hannah
    Wilke, Hans-Joachim
    CLINICAL BIOMECHANICS, 2018, 56 : 40 - 45