MRI vs. CT for the Detection of Liver Metastases in Patients With Pancreatic Carcinoma: A Comparative Diagnostic Test Accuracy Systematic Review and Meta-Analysis

被引:31
|
作者
Alabousi, Mostafa [1 ]
McInnes, Matthew D. F. [2 ,3 ]
Salameh, Jean-Paul [4 ]
Satkunasingham, Janakan [5 ,6 ]
Kagoma, Yoan K. [5 ,6 ]
Ruo, Leyo [6 ,7 ]
Meyers, Brandon M. [6 ,8 ]
Aziz, Tariq [6 ,9 ]
van der Pol, Christian B. [5 ,6 ]
机构
[1] McMaster Univ, Hamilton Hlth Sci, Dept Radiol, Hamilton, ON, Canada
[2] Univ Ottawa, Dept Radiol & Epidemiol, Ottawa, ON, Canada
[3] Ottawa Hosp Res Inst, Clin Epidemiol Program, Ottawa, ON, Canada
[4] Univ Ottawa, Sch Epidemiol & Publ Hlth, Clin Epidemiol Program, Ottawa Hosp Res Inst, Ottawa, ON, Canada
[5] McMaster Univ, Juravinski Hosp, Dept Diagnost Imaging, Hamilton, ON, Canada
[6] McMaster Univ, Hamilton Hlth Sci, Canc Ctr, Hamilton, ON, Canada
[7] McMaster Univ, Juravinski Hosp, Dept Surg, Hamilton, ON, Canada
[8] McMaster Univ, Juravinski Hosp, Dept Med Oncol, Hamilton, ON, Canada
[9] McMaster Univ, Juravinski Hosp, Dept Pathol & Mol Med, Hamilton, ON, Canada
关键词
magnetic resonance imaging; multidetector computed tomography; pancreatic neoplasms; systematic review; meta-analysis; ADENOCARCINOMA; CANCER;
D O I
10.1002/jmri.27056
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background The detection of liver metastases is important for pancreatic cancer curative treatment eligibility. The data suggest that magnetic resonance imaging (MRI) is more sensitive than computed tomography (CT) for the diagnosis of pancreatic cancer liver metastases. However, MRI is not currently recommended in multiple published guidelines. Purpose To perform a comparative diagnostic test accuracy systematic review and meta-analysis comparing CT and MRI for pancreatic cancer liver metastases detection. Study Type Systematic review and meta-analysis. Data Sources MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Scopus, and multiple radiology society meeting archives were searched until November 2018. Comparative design studies reporting on liver CT and MRI accuracy for detection of pancreatic cancer liver metastases in the same cohort were included. Field Strength 1.5T or 3.0T. Assessment Demographic, methodologic, and diagnostic test accuracy data were extracted. Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool. Statistical Tests Accuracy metrics were obtained using bivariate random-effects meta-analysis. The impact of different covariates on accuracy estimates was assessed using a meta-regression model. Covariates included modality, study design, tumor characteristics, risk of bias, and imaging protocols. Results Fourteen studies including 987 patients with pancreatic cancer (205 with liver metastases) were included. Sensitivity for CT and MRI was 45% (confidence intervals [95% CI] 21-71%) and 83% (95% CI 74-88%), respectively. Specificity for CT and MRI was 94% (95% CI 84-98%) and 96% (95% CI 93-97%), respectively. The greater observed sensitivity of MRI was preserved in the meta-regression model (P = 0.01), while no difference in specificity was detected (P = 0.16). CT sensitivity was highest for triphasic and quadriphasic examinations compared to single phase or biphasic protocols (P = 0.03). Most studies were at high risk of bias. Data Conclusion MRI is more sensitive than CT for pancreatic cancer liver metastases detection, accounting for confounding variables. Consideration of this finding in clinical practice guidelines is recommended. Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2020.
引用
收藏
页码:38 / 48
页数:11
相关论文
共 50 条
  • [1] Editorial for "MRI vs. CT for the Detection of Liver Metastases in Patients With Pancreatic Carcinoma: A Comparative Diagnostic Test Accuracy Systematic Review and Meta-Analysis"
    Hecht, Elizabeth M.
    Zins, Marc
    Tamm, Eric P.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (01) : 49 - 50
  • [2] MRI vs. CT for pancreatic adenocarcinoma vascular invasion: comparative diagnostic test accuracy systematic review and meta-analysis
    Ankush Jajodia
    Ashley Wang
    Mostafa Alabousi
    Christopher Wilks
    Ameya Kulkarni
    Christian B. van der Pol
    European Radiology, 2023, 33 : 6883 - 6891
  • [3] MRI vs. CT for pancreatic adenocarcinoma vascular invasion: comparative diagnostic test accuracy systematic review and meta-analysis
    Jajodia, Ankush
    Wang, Ashley
    Alabousi, Mostafa
    Wilks, Christopher
    Kulkarni, Ameya
    van der Pol, Christian B.
    EUROPEAN RADIOLOGY, 2023, 33 (10) : 6883 - 6891
  • [4] The diagnostic accuracy of CT and MRI for the detection of lymph node metastases in gallbladder cancer: A systematic review and meta-analysis
    Lohman, E. A. J. de Savornin
    de Bitter, T. J. J.
    van Laarhoven, C. J. H. M.
    Hermans, J. J.
    de Haas, R. J.
    de Reuver, P. R.
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 110 : 156 - 162
  • [5] Whole-Body MRI vs. PET/CT for the Detection of Bone Metastases in Patients With Prostate Cancer: A Systematic Review and Meta-Analysis
    Zhan, Yuefu
    Zhang, Guangming
    Li, Mingliang
    Zhou, Xiaobo
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [6] CEUS compared with CECT, MRI, and FDG-PET/CT for diagnosing CRC liver metastases: a diagnostic test accuracy systematic review and meta-analysis
    Lund, Martin
    Bjerre, Thomas A.
    Gronbaek, Henning
    Mortensen, Frank V.
    Andersen, Per Kragh
    EXPERT REVIEW OF GASTROENTEROLOGY & HEPATOLOGY, 2024, 18 (09) : 541 - 549
  • [7] Diagnostic Accuracy of MRI for Detection of Papillary Renal Cell Carcinoma: A Systematic Review and Meta-Analysis
    Chiarello, Matthew A.
    Mali, Rahul D.
    Kang, Stella K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (04) : 812 - 821
  • [8] Comparative Analysis of Diagnostic Techniques for Melanoma Detection: A Systematic Review of Diagnostic Test Accuracy Studies and Meta-Analysis
    Blundo, Alessia
    Cignoni, Arianna
    Banfi, Tommaso
    Ciuti, Gastone
    FRONTIERS IN MEDICINE, 2021, 8
  • [9] Diagnostic Accuracy of CT for the Detection of Hepatic Steatosis: A Systematic Review and Meta-Analysis
    Haghshomar, Maryam
    Antonacci, Dominic
    Smith, Andrew D.
    Thaker, Sarang
    Miller, Frank H.
    Borhani, Amir A.
    RADIOLOGY, 2024, 313 (02)
  • [10] Diagnostic accuracy of xpert test in tuberculosis detection: A systematic review and meta-analysis
    Kaur, Ravdeep
    Kachroo, Kavita
    Sharma, Jitendar Kumar
    Vatturi, Satyanarayana Murthy
    Dang, Amit
    JOURNAL OF GLOBAL INFECTIOUS DISEASES, 2016, 8 (01) : 32 - 40