Purpose: T2‐weighting in fast spin echo (FSE) images is unavoidably affected by T1‐mixing due to stimulated echoes. The purpose of this research is to evaluate the feasibility of using a multishot echo‐planar (EPI) technique to image the prostate at 3 Tesla without an endorectal coil and to compare T2 quantification using EPI with that based off of FSE images. Method and Materials: All experiments were performed on a GE Signa 3 Tesla whole body scanner with an 8‐channel torso phased‐array coil. T2‐weighted images were acquired of a healthy volunteer at echo times (TEs) of 40, 80 and 110 ms with a multishot spin‐echo EPI. Other imaging parameters were: 32cm FOV, 16 shots, TR = 2000ms, acquisition matrix = 256×512, receiver bandwidth = ±250 kHz. FSE images were obtained of the same volunteer with TEs of 60, 120, and 180ms and these acquisition parameters: 16cm FOV, TR = 3900ms, acquisition matrix = 256×256, ETL = 16, bandwidth = ±32kHz. A total of eleven slices covering the entire prostate were collected using both techniques. Results: The EPI images showed few artifacts and were noted to provide better T2‐contrast than the FSE images. For a region‐of‐interest in the peripheral zone of the prostate, T2 values derived from FSE images (134±15 ms) are substantially larger than those based on EPI images (76±1 ms). This observation is consistent with the apparent lengthening of T2 due to T1 mixing in FSE images. Conclusion: Using EPI with high receiver bandwidth, our results indicate that high quality T2‐weighted images of the prostate can be obtained at 3T without an endorectal coil. T2‐weighted images by EPI provide pure T2‐contrast and possibly more accurate T2‐determination than conventional FSE images. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1911 / 1911
页数:1
相关论文
共 50 条
  • [41] Quantification of Hepatic Iron Concentration in Chronic Viral Hepatitis: Usefulness of T2-weighted Single-Shot Spin-Echo Echo-Planar MR Imaging
    Tonan, Tatsuyuki
    Fujimoto, Kiminori
    Qayyum, Aliya
    Kawaguchi, Takumi
    Kawaguchi, Atsushi
    Nakashima, Osamu
    Okuda, Koji
    Hayabuchi, Naofumi
    Sata, Michio
    PLOS ONE, 2012, 7 (03):
  • [42] Fast high resolution whole brain T2* weighted imaging using echo planar imaging at 7 T
    Zwanenburg, Jaco J. M.
    Versluis, Maarten J.
    Luijten, Peter R.
    Petridou, Natalia
    NEUROIMAGE, 2011, 56 (04) : 1902 - 1907
  • [43] Identification of the primary motor cortex: value of T2 echo-planar imaging, diffusion-weighted imaging and quantitative apparent diffusion coefficient measurement at 3 T
    Dincer, Alp
    Ozyurt, Onur
    Erzen, Canan
    Pamir, M. Necmettin
    EUROPEAN RADIOLOGY, 2010, 20 (04) : 931 - 940
  • [44] Robust Fat Suppression at 3T in High-Resolution Diffusion-Weighted Single-Shot Echo-Planar Imaging of Human Brain
    Sarlls, Joelle E.
    Pierpaoli, Carlo
    Talagala, S. Lalith
    Luh, Wen-Ming
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (06) : 1658 - 1665
  • [45] Prostate cancer detection with 3-T MRI: Comparison of diffusion-weighted and T2-weighted imaging
    Miao, Huadong
    Fukatsu, Hiroshi
    Ishigaki, Takeo
    EUROPEAN JOURNAL OF RADIOLOGY, 2007, 61 (02) : 297 - 302
  • [46] Identification of the primary motor cortex: value of T2 echo-planar imaging, diffusion-weighted imaging and quantitative apparent diffusion coefficient measurement at 3 T
    Alp Dinçer
    Onur Özyurt
    Canan Erzen
    M. Necmettin Pamir
    European Radiology, 2010, 20 : 931 - 940
  • [47] Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration
    Park, Hee Jin
    Lee, So Yeon
    Rho, Myung Ho
    Chung, Eun Chul
    Kim, Mi Sung
    Kwon, Heon Ju
    Youn, In Young
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (05) : 590 - 597
  • [48] CONTRAST IN RAPID MR IMAGING - T1-WEIGHTED AND T2-WEIGHTED IMAGING
    BUXTON, RB
    EDELMAN, RR
    ROSEN, BR
    WISMER, GL
    BRADY, TJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) : 7 - 16
  • [49] ECHO-PLANAR IMAGING OF THE CENTRAL-NERVOUS-SYSTEM AT 1.0 T
    SCHMITT, F
    STEHLING, MK
    LADEBECK, R
    FANG, M
    QUAIYUMI, A
    BARSCHNEIDER, E
    HUK, WJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04): : 473 - 478
  • [50] Cholesteatoma imaging using modified echo-planar diffusion-weighted magnetic resonance imaging
    Flook, E.
    Izzat, S.
    Ismail, A.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2011, 125 (01): : 10 - 12