摘要
Purpose: T2‐weighting in fast spin echo (FSE) images is unavoidably affected by T1‐mixing due to stimulated echoes. The purpose of this research is to evaluate the feasibility of using a multishot echo‐planar (EPI) technique to image the prostate at 3 Tesla without an endorectal coil and to compare T2 quantification using EPI with that based off of FSE images. Method and Materials: All experiments were performed on a GE Signa 3 Tesla whole body scanner with an 8‐channel torso phased‐array coil. T2‐weighted images were acquired of a healthy volunteer at echo times (TEs) of 40, 80 and 110 ms with a multishot spin‐echo EPI. Other imaging parameters were: 32cm FOV, 16 shots, TR = 2000ms, acquisition matrix = 256×512, receiver bandwidth = ±250 kHz. FSE images were obtained of the same volunteer with TEs of 60, 120, and 180ms and these acquisition parameters: 16cm FOV, TR = 3900ms, acquisition matrix = 256×256, ETL = 16, bandwidth = ±32kHz. A total of eleven slices covering the entire prostate were collected using both techniques. Results: The EPI images showed few artifacts and were noted to provide better T2‐contrast than the FSE images. For a region‐of‐interest in the peripheral zone of the prostate, T2 values derived from FSE images (134±15 ms) are substantially larger than those based on EPI images (76±1 ms). This observation is consistent with the apparent lengthening of T2 due to T1 mixing in FSE images. Conclusion: Using EPI with high receiver bandwidth, our results indicate that high quality T2‐weighted images of the prostate can be obtained at 3T without an endorectal coil. T2‐weighted images by EPI provide pure T2‐contrast and possibly more accurate T2‐determination than conventional FSE images. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1911 / 1911
页数:1
相关论文
共 50 条
  • [31] CORONARY-ARTERY IMAGING AT 0.5 T USING SEGMENTED 3D ECHO-PLANAR IMAGING
    BORNERT, P
    JENSEN, D
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) : 779 - 785
  • [32] B-Mode and Acoustic Radiation Force Impulse (ARFI) Imaging of Prostate Zonal Anatomy: Comparison with 3T T2-Weighted MR Imaging
    Palmeri, Mark L.
    Miller, Zachary A.
    Glass, Tyler J.
    Garcia-Reyes, Kirema
    Gupta, Rajan T.
    Rosenzweig, Stephen J.
    Kauffman, Christopher
    Polascik, Thomas J.
    Buck, Andrew
    Kulbacki, Evan
    Madden, John
    Lipman, Samantha L.
    Rouze, Ned C.
    Nightingale, Kathryn R.
    ULTRASONIC IMAGING, 2015, 37 (01) : 22 - 41
  • [33] Optimization of Gradient-Echo Echo-Planar Imaging for T2* Contrast in the Brain at 0.5 T
    Halder, Arjama
    Harris, Chad T.
    Wiens, Curtis N.
    Soddu, Andrea
    Chronik, Blaine A.
    SENSORS, 2023, 23 (20)
  • [34] T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI
    Kang, Kyung A.
    Kim, Young Kon
    Kim, EunJu
    Jeong, Woo Kyoung
    Choi, Dongil
    Lee, Won Jae
    Jung, Sin-Ho
    Baek, Sun-Young
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (05) : 1038 - 1046
  • [35] ECHO-PLANAR IMAGING
    DELAPAZ, RL
    RADIOGRAPHICS, 1994, 14 (05) : 1045 - 1058
  • [36] Distortion correction in echo-planar imaging and quantitative T2* mapping
    Dierkes, T
    Neeb, H
    Shah, NJ
    QUANTITATION IN BIOMEDICAL IMAGING WITH PET AND MRI, 2004, (1265): : 181 - 185
  • [37] Echo-Planar Imaging
    University of Nottingham, United Kingdom
    eMagRes, 2007,
  • [38] T2 selective π Echo-Planar Imaging for porous media MRI
    Xiao, Dan
    Balcom, Bruce J.
    JOURNAL OF MAGNETIC RESONANCE, 2017, 277 : 52 - 58
  • [39] Fast 3D T2-weighted imaging using variable flip angle transition into driven equilibrium (3D T2-TIDE) balanced SSFP for prostate imaging at 3T
    Srinivasan, Subashini
    Wu, Holden H.
    Sung, Kyunghyun
    Margolis, Daniel J. A.
    Ennis, Daniel B.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) : 442 - 451
  • [40] Hemodynamic characterization of focal hepatic lesions: Role of ferucarbotran-enhanced dynamic MR imaging using T2-weighted multishot spin-echo echo-planar sequence
    Hori, M
    Murakami, T
    Kim, T
    Iannaccone, R
    Abe, H
    Onishi, H
    Tomoda, K
    Catalano, C
    Passariello, R
    Nakamura, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (04) : 509 - 519