T2-weighted prostate imaging using echo-planar imaging at 3T

被引:0
|
作者
Ragan, D [1 ]
Ma, J [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.1997513
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: T2‐weighting in fast spin echo (FSE) images is unavoidably affected by T1‐mixing due to stimulated echoes. The purpose of this research is to evaluate the feasibility of using a multishot echo‐planar (EPI) technique to image the prostate at 3 Tesla without an endorectal coil and to compare T2 quantification using EPI with that based off of FSE images. Method and Materials: All experiments were performed on a GE Signa 3 Tesla whole body scanner with an 8‐channel torso phased‐array coil. T2‐weighted images were acquired of a healthy volunteer at echo times (TEs) of 40, 80 and 110 ms with a multishot spin‐echo EPI. Other imaging parameters were: 32cm FOV, 16 shots, TR = 2000ms, acquisition matrix = 256×512, receiver bandwidth = ±250 kHz. FSE images were obtained of the same volunteer with TEs of 60, 120, and 180ms and these acquisition parameters: 16cm FOV, TR = 3900ms, acquisition matrix = 256×256, ETL = 16, bandwidth = ±32kHz. A total of eleven slices covering the entire prostate were collected using both techniques. Results: The EPI images showed few artifacts and were noted to provide better T2‐contrast than the FSE images. For a region‐of‐interest in the peripheral zone of the prostate, T2 values derived from FSE images (134±15 ms) are substantially larger than those based on EPI images (76±1 ms). This observation is consistent with the apparent lengthening of T2 due to T1 mixing in FSE images. Conclusion: Using EPI with high receiver bandwidth, our results indicate that high quality T2‐weighted images of the prostate can be obtained at 3T without an endorectal coil. T2‐weighted images by EPI provide pure T2‐contrast and possibly more accurate T2‐determination than conventional FSE images. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1911 / 1911
页数:1
相关论文
共 50 条
  • [21] Spatial resolution enhancement using sensitivity-encoded echo-planar imaging at 3T in a typical motor paradigm
    Schmidt, Conny R.
    Pruessmann, Klaas. P.
    Boesiger, Peter
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2007, 31 (08) : 704 - 714
  • [22] SNAPSHOT IMAGING AT 0.5-T USING ECHO-PLANAR TECHNIQUES
    ORDIDGE, RJ
    HOWSEMAN, A
    COXON, R
    TURNER, R
    CHAPMAN, B
    GLOVER, P
    STEHLING, M
    MANSFIELD, P
    MAGNETIC RESONANCE IN MEDICINE, 1989, 10 (02) : 227 - 240
  • [23] Comparison of Ferucarbotran-Enhanced Fluid-Attenuated Inversion-Recovery Echo-Planar, T2-Weighted Turbo Spin-Echo, T2*-Weighted Gradient-Echo, and Diffusion-Weighted Echo-Planar Imaging for Detection of Malignant Liver Lesions
    Fukukura, Yoshihiko
    Kamiyama, Takuro
    Takumi, Koji
    Shindo, Toshikazu
    Higashi, Ryutaro
    Nakajo, Masayuki
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 607 - 616
  • [24] Feasibility of T2-Weighted Turbo Spin Echo Imaging of the Human Prostate at 7 Tesla
    Maas, Marnix C.
    Vos, Eline K.
    Lagemaat, Miriam W.
    Bitz, Andreas K.
    Orzada, Stephan
    Kobus, Thiele
    Kraff, Oliver
    Maderwald, Stefan
    Ladd, Mark E.
    Scheenen, Tom W. J.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1711 - 1719
  • [25] Superficial Siderosis Associated With a Chronic Subdural Hematoma: T2-Weighted MR Imaging at 3T
    Kakeda, Shingo
    Korogi, Yukunori
    Ohnari, Norihiro
    Nishimura, Johji
    Moriya, Junji
    Yamamoto, Junkoh
    Nishizawa, Shigeru
    ACADEMIC RADIOLOGY, 2010, 17 (07) : 871 - 876
  • [26] Diagnosis of cerebral venous thrombosis with echo-planar T2*-weighted magnetic resonance imaging
    Selim, M
    Fink, J
    Linfante, I
    Kumar, S
    Schlaug, G
    Caplan, LR
    ARCHIVES OF NEUROLOGY, 2002, 59 (06) : 1021 - 1026
  • [27] Improvement of renal diffusion-weighted magnetic resonance imaging with readout-segmented echo-planar imaging at 3 T
    Friedli, Iris
    Crowe, Lindsey A.
    Viallon, Magalie
    Porter, David A.
    Martin, Pierre-Yves
    de Seigneux, Sophie
    Vallee, Jean-Paul
    MAGNETIC RESONANCE IMAGING, 2015, 33 (06) : 701 - 708
  • [28] High-Resolution Diffusion-Weighted Imaging of Neck Lymph Nodes Using 2D-Single-Shot Interleaved Multiple Inner Volume Imaging Diffusion-Weighted Echo-Planar Imaging at 3T
    Park, J. K.
    Kim, S. -E.
    Trieman, G. S.
    Parker, D.
    Jeong, E. -K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) : 1173 - 1177
  • [29] Accelerated T2-Weighted TSE Imaging of the Prostate Using Deep Learning Image Reconstruction: A Prospective Comparison with Standard T2-Weighted TSE Imaging
    Gassenmaier, Sebastian
    Afat, Saif
    Nickel, Marcel Dominik
    Mostapha, Mahmoud
    Herrmann, Judith
    Almansour, Haidara
    Nikolaou, Konstantin
    Othman, Ahmed E.
    CANCERS, 2021, 13 (14)
  • [30] Readout-segmented Echo-planar Imaging for Diffusion-weighted Imaging in the Pelvis at 3T-A Feasibility Study
    Thian, Yee Liang
    Xie, Wanying
    Porter, David A.
    Ang, Bertrand Weileng
    ACADEMIC RADIOLOGY, 2014, 21 (04) : 531 - 537