T2-weighted prostate imaging using echo-planar imaging at 3T

被引:0
|
作者
Ragan, D [1 ]
Ma, J [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.1997513
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: T2‐weighting in fast spin echo (FSE) images is unavoidably affected by T1‐mixing due to stimulated echoes. The purpose of this research is to evaluate the feasibility of using a multishot echo‐planar (EPI) technique to image the prostate at 3 Tesla without an endorectal coil and to compare T2 quantification using EPI with that based off of FSE images. Method and Materials: All experiments were performed on a GE Signa 3 Tesla whole body scanner with an 8‐channel torso phased‐array coil. T2‐weighted images were acquired of a healthy volunteer at echo times (TEs) of 40, 80 and 110 ms with a multishot spin‐echo EPI. Other imaging parameters were: 32cm FOV, 16 shots, TR = 2000ms, acquisition matrix = 256×512, receiver bandwidth = ±250 kHz. FSE images were obtained of the same volunteer with TEs of 60, 120, and 180ms and these acquisition parameters: 16cm FOV, TR = 3900ms, acquisition matrix = 256×256, ETL = 16, bandwidth = ±32kHz. A total of eleven slices covering the entire prostate were collected using both techniques. Results: The EPI images showed few artifacts and were noted to provide better T2‐contrast than the FSE images. For a region‐of‐interest in the peripheral zone of the prostate, T2 values derived from FSE images (134±15 ms) are substantially larger than those based on EPI images (76±1 ms). This observation is consistent with the apparent lengthening of T2 due to T1 mixing in FSE images. Conclusion: Using EPI with high receiver bandwidth, our results indicate that high quality T2‐weighted images of the prostate can be obtained at 3T without an endorectal coil. T2‐weighted images by EPI provide pure T2‐contrast and possibly more accurate T2‐determination than conventional FSE images. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1911 / 1911
页数:1
相关论文
共 50 条
  • [1] T2-weighted MR imaging of prostate cancer: multishot echo-planar imaging vs fast spin-echo imaging
    Tamada, T
    Sone, T
    Nagai, K
    Jo, Y
    Gyoten, M
    Imai, S
    Kajihara, Y
    Fukunaga, M
    EUROPEAN RADIOLOGY, 2004, 14 (02) : 318 - 325
  • [2] T2-weighted MR imaging of prostate cancer: multishot echo-planar imaging vs fast spin-echo imaging
    Tsutomu Tamada
    Teruki Sone
    Kiyohisa Nagai
    Yoshimasa Jo
    Masayuki Gyoten
    Shigeki Imai
    Yasumasa Kajihara
    Masao Fukunaga
    European Radiology, 2004, 14 : 318 - 325
  • [3] Zoomed echo-planar imaging using parallel transmission: impact on image quality of diffusion-weighted imaging of the prostate at 3T
    Andrew B. Rosenkrantz
    Hersh Chandarana
    Josef Pfeuffer
    Michael J. Triolo
    Mohammed Bilal Shaikh
    David J. Mossa
    Christian Geppert
    Abdominal Imaging, 2015, 40 : 120 - 126
  • [4] Zoomed echo-planar imaging using parallel transmission: impact on image quality of diffusion-weighted imaging of the prostate at 3T
    Rosenkrantz, Andrew B.
    Chandarana, Hersh
    Pfeuffer, Josef
    Triolo, Michael J.
    Shaikh, Mohammed Bilal
    Mossa, David J.
    Geppert, Christian
    ABDOMINAL IMAGING, 2015, 40 (01): : 120 - 126
  • [5] Hemorrhagic and nonhemorrhagic stroke: Diagnosis with diffusion-weighted and T2-weighted echo-planar MR imaging
    Ebisu, T
    Tanaka, C
    Umeda, M
    Kitamura, M
    Fukunaga, M
    Aoki, I
    Sato, H
    Higuchi, T
    Naruse, S
    Horikawa, Y
    Ueda, S
    RADIOLOGY, 1997, 203 (03) : 823 - 828
  • [6] Multi-Echo-Based Echo-Planar Spectroscopic Imaging Using a 3T MRI Scanner
    Furuyama, Jon K.
    Burns, Brian L.
    Wilson, Neil E.
    Thomas, M. Albert
    MATERIALS, 2011, 4 (10): : 1818 - 1834
  • [7] T2-weighted echo planar MR imaging of the abdomen - Optimization of imaging parameters
    Li, T
    Mirowitz, SA
    CLINICAL IMAGING, 2003, 27 (02) : 124 - 128
  • [8] High-speed 3T MR spectroscopic imaging of prostate with flyback echo-planar encoding
    Chen, Albert P.
    Cunningham, Charles H.
    Ozturk-Isik, Esin
    Xu, Duan
    Hurd, Ralph E.
    Kelley, Douglas A. C.
    Pauly, John M.
    Kurhanewicz, John
    Nelson, Sarah J.
    Vigneron, Daniel B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (06) : 1288 - 1292
  • [9] Functional assessment of pancreatic parenchyma after secretin administration using serial T2-weighted echo-planar MR imaging
    Masui, T
    Katayama, M
    Kobayashi, S
    Ito, T
    Nozaki, A
    Sakahara, H
    RADIOLOGY, 2001, 221 : 589 - 589
  • [10] Functional assessment of pancreatic parenchyma after secretin administration using serial t2-weighted echo-planar magnetic resonance Imaging
    Masui, T
    Katayama, M
    Kobayashi, S
    Ito, T
    Kabasawa, H
    Nozaki, A
    Sakahara, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) : 450 - 456