The Physiologic effects of a conducted electrical weapon in swine

被引:14
|
作者
Esquivel, Amanda O.
Dawe, Elizabeth J.
Sala-Mercado, Javier A.
Hammond, Robert L.
Bir, Cynthia A.
机构
[1] Wayne State Univ, Coll Engn, Detroit, MI USA
[2] Wayne State Univ, Coll Med, Surg Res Serv, Sch Med, Detroit, MI USA
关键词
D O I
10.1016/j.annemergmed.2007.05.003
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: By using an animal model, we determine whether repeated exposures to a conducted electrical weapon could have physiologic consequences. Methods: Exposures to the Stinger S-400 conducted electrical weapon were applied to 10 healthy, anesthetized, Yorkshire-cross, male swine by attaching probes from the cartridge to the sternal notch and anterolateral thorax at a distance of 21.5 cm. The standard pulse generated by the Stinger S-400 during the normal application was applied 20 times during 31 minutes. To evaluate the health effects of the exposures, key physiologic characteristics were evaluated, including arterial pH, PCO2, PO2, blood lactate, cardiac output, ECG, pulse rate, mean arterial pressure, central venous pressure, pulmonary artery pressure and airway pressure, and the cardiac marker troponin l. Results: There were notable changes in pH, PCO2, blood lactate, cardiac output, and mean arterial pressure after 1 or more sets of exposures, all of which normalized during the next few hours. Troponin l PO2, pulse rate, mean arterial pressure, central venous pressure, pulmonary artery pressure, and airway pressure did not change markedly during or after the shocks. Three premature ventricular contractions occurred in one animal; all other ECG results were normal. Conclusion: Repeated exposures to a conducted electrical weapon result in respiratory acidosis, metabolic vasodilation, and an increase in blood lactate level. These effects were transient in this study, with full recovery by 4 hours postexposure. The Stinger S-400 appears to have no serious adverse physiologic effects on healthy, anesthetized swine.
引用
收藏
页码:576 / 583
页数:8
相关论文
共 50 条
  • [21] Conducted Electrical Weapon Injuries Must Be More Broadly Considered
    Strote, Jared
    Hutson, H. Range
    ANNALS OF EMERGENCY MEDICINE, 2009, 54 (02) : 310 - 311
  • [22] Confirmation of respiration during trapezial conducted electrical weapon application
    Ho, Jeffrey
    Lapine, Anne
    Joing, Scott
    Reardon, Robert
    Dawes, Donald
    ACADEMIC EMERGENCY MEDICINE, 2008, 15 (04) : 398 - 398
  • [23] The neuroendocrine effects of the TASER X26 conducted electrical weapon as compared to oleoresin capsicum
    Dawes, D. M.
    Ho, J. D.
    Miner, J. R.
    Johnson, M.
    ANNALS OF EMERGENCY MEDICINE, 2007, 50 (03) : S132 - S133
  • [24] Penetration Depths of Conducted Electrical Weapon Probes Into Human Skull Phantoms
    Bolliger, Stephan Andreas
    Gort, Silvan
    Kaelin, Beat
    Barrera, Vera
    Thali, Michael Josef
    Martinez, Rosa Maria
    AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 2019, 40 (02): : 102 - 107
  • [25] Human Health Risks of Conducted Electrical Weapon Exposure A Systematic Review
    Baliatsas, Christos
    Gerbecks, Jenny
    Duckers, Michel L. A.
    Yzermans, C. Joris
    JAMA NETWORK OPEN, 2021, 4 (02)
  • [26] Conducted Electrical Weapon Use by Law Enforcement: An Evaluation of Safety and Injury
    Strote, Jared
    Walsh, Mimi
    Angelidis, Matthew
    Basta, Amaya
    Hutson, H. Range
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (05): : 1239 - 1246
  • [27] Conducted Electrical Weapon Injuries Must Be More Broadly Considered Reply
    Bozeman, William P.
    Winslow, James E., II
    Hauda, William E., II
    ANNALS OF EMERGENCY MEDICINE, 2009, 54 (02) : 311 - 312
  • [28] Conducted Electrical Weapon (TASER) Use Against Minors A Shocking Analysis
    Gardner, Alison R.
    Hauda, William E., II
    Bozeman, William P.
    PEDIATRIC EMERGENCY CARE, 2012, 28 (09) : 873 - 877
  • [29] SAFETY OF TRANSCARDIAC CONDUCTED ELECTRICAL WEAPON PROBE DEPLOYMENTS REMAINS UNCLEAR
    Strote, Jared
    JOURNAL OF EMERGENCY MEDICINE, 2014, 46 (04): : 534 - 534
  • [30] TRANSCARDIAC CONDUCTED ELECTRICAL WEAPON (TASER) PROBE DEPLOYMENTS: INCIDENCE AND OUTCOMES
    Bozeman, William P.
    Teacher, Eric
    Winslow, James E.
    JOURNAL OF EMERGENCY MEDICINE, 2012, 43 (06): : 970 - 975