TRANSCARDIAC CONDUCTED ELECTRICAL WEAPON (TASER) PROBE DEPLOYMENTS: INCIDENCE AND OUTCOMES

被引:19
|
作者
Bozeman, William P. [1 ]
Teacher, Eric [2 ]
Winslow, James E. [1 ]
机构
[1] Wake Forest Univ, Bowman Gray Sch Med, Dept Emergency Med, Winston Salem, NC 27106 USA
[2] Loma Linda Univ, Med Ctr, Dept Emergency Med, Loma Linda, CA USA
来源
JOURNAL OF EMERGENCY MEDICINE | 2012年 / 43卷 / 06期
关键词
TASER; conducted electrical weapon; conducted energy weapon; conducted electrical device; conducted energy device; injuries; cardiac; dysrhythmia; ELECTRONIC CONTROL DEVICE; X26; DISCHARGES; STUN GUNS; ECHOCARDIOGRAPHIC EVALUATION; EXPOSURE; CAPTURE; SAFETY;
D O I
10.1016/j.jemermed.2012.03.022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: TASER (TASER International, Scottsdale, AZ) conducted electrical weapons (CEWs) are commonly used by law enforcement officers. Although animal studies have suggested that transcardiac CEW discharges may produce direct cardiac effects, this has not been demonstrated in human studies. Objectives: This study sought to determine the incidence and outcomes of transcardiac CEW probe impact locations in a large series of actual CEW deployments. Methods: A multi-center database of consecutive CEW uses by law enforcement officers was retrospectively reviewed. Case report forms were independently reviewed by three investigators to identify cases with paired probe configurations potentially producing a transcardiac discharge vector. Descriptive analysis was performed and inter-rater reliability was assessed. Results: Among 1201 total CEW uses, 813 included probe deployments and 178 cases had paired anterior probe impacts potentially capable of producing a transcardiac discharge vector. This represents 14.8% of all CEW uses (95% confidence interval [CI] 12.9-16.9%) and 21.9% of CEW uses in probe mode (95% CI 19.1-24.9%). Inter-rater agreement was very good, with kappa = 0.82. There were no immediate deaths in any cases (97.5% CI 0.0-0.3%) to suggest a cardiac dysrhythmia, including those with transcardiac discharge vector. Conclusion: CEW deployments with probe impact configurations capable of producing a transcardiac discharge occur in a minority of cases in field use conditions. None of these cases, transcardiac or otherwise, produced immediately fatal dysrhythmias. These data support the overall safety of CEWs and provide a benchmark estimate of the likelihood of transcardiac discharge vectors occurring in field use of CEWs. (C) 2012 Elsevier Inc.
引用
收藏
页码:970 / 975
页数:6
相关论文
共 50 条
  • [1] SAFETY OF TRANSCARDIAC CONDUCTED ELECTRICAL WEAPON PROBE DEPLOYMENTS REMAINS UNCLEAR
    Strote, Jared
    JOURNAL OF EMERGENCY MEDICINE, 2014, 46 (04): : 534 - 534
  • [2] SAFETY OF TRANSCARDIAC CONDUCTED ELECTRICAL WEAPON PROBE DEPLOYMENTS REMAINS UNCLEAR RESPONSE
    Bozeman, William P.
    Winslow, James E.
    Teacher, Eric
    JOURNAL OF EMERGENCY MEDICINE, 2014, 46 (04): : 535 - 535
  • [3] Conducted Electrical Weapon (TASER) Use Against Minors A Shocking Analysis
    Gardner, Alison R.
    Hauda, William E., II
    Bozeman, William P.
    PEDIATRIC EMERGENCY CARE, 2012, 28 (09) : 873 - 877
  • [4] Immediate cardiovascular effects of the Taser X26 conducted electrical weapon
    Bozeman, W. P.
    Barnes, D. G., Jr.
    Winslow, J. E., III
    Johnson, J. C., III
    Phillips, C. H.
    Alson, R.
    EMERGENCY MEDICINE JOURNAL, 2009, 26 (08) : 567 - 570
  • [5] Cardiac effects of the Taser conducted energy weapon
    Barnes, D. G., Jr.
    Winslow, J. E., III
    Alson, R. L.
    Johnson, J.
    Bozeman, W. P.
    ANNALS OF EMERGENCY MEDICINE, 2006, 48 (04) : S102 - S102
  • [6] A TASER conducted electrical weapon with cardiac biomonitoring capability: Proof of concept and initial human trial
    Stopyra, Jason P.
    Ritter, Samuel I.
    Beatty, Jennifer
    Johnson, James C.
    Kleiner, Douglas M.
    Winslow, James E., III
    Gardner, Alison R.
    Bozeman, William P.
    JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2016, 43 : 48 - 52
  • [7] The neuroendocrine effects of the TASER X26 conducted electrical weapon as compared to oleoresin capsicum
    Dawes, D. M.
    Ho, J. D.
    Miner, J. R.
    Johnson, M.
    ANNALS OF EMERGENCY MEDICINE, 2007, 50 (03) : S132 - S133
  • [8] Physiological effects of the TASER® C2 conducted energy weapon
    James R. Jauchem
    Ronald L. Seaman
    Curtis M. Klages
    Forensic Science, Medicine, and Pathology, 2009, 5 : 330 - 330
  • [9] Physiological effects of the TASER® C2 conducted energy weapon
    James R. Jauchem
    Ronald L. Seaman
    Curtis M. Klages
    Forensic Science, Medicine, and Pathology, 2009, 5
  • [10] Physiological effects of the TASER® C2 conducted energy weapon
    Jauchem, James R.
    Seaman, Ronald L.
    Klages, Curtis M.
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2009, 5 (03) : 189 - 198