The Physiologic effects of a conducted electrical weapon in swine

被引:14
|
作者
Esquivel, Amanda O.
Dawe, Elizabeth J.
Sala-Mercado, Javier A.
Hammond, Robert L.
Bir, Cynthia A.
机构
[1] Wayne State Univ, Coll Engn, Detroit, MI USA
[2] Wayne State Univ, Coll Med, Surg Res Serv, Sch Med, Detroit, MI USA
关键词
D O I
10.1016/j.annemergmed.2007.05.003
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: By using an animal model, we determine whether repeated exposures to a conducted electrical weapon could have physiologic consequences. Methods: Exposures to the Stinger S-400 conducted electrical weapon were applied to 10 healthy, anesthetized, Yorkshire-cross, male swine by attaching probes from the cartridge to the sternal notch and anterolateral thorax at a distance of 21.5 cm. The standard pulse generated by the Stinger S-400 during the normal application was applied 20 times during 31 minutes. To evaluate the health effects of the exposures, key physiologic characteristics were evaluated, including arterial pH, PCO2, PO2, blood lactate, cardiac output, ECG, pulse rate, mean arterial pressure, central venous pressure, pulmonary artery pressure and airway pressure, and the cardiac marker troponin l. Results: There were notable changes in pH, PCO2, blood lactate, cardiac output, and mean arterial pressure after 1 or more sets of exposures, all of which normalized during the next few hours. Troponin l PO2, pulse rate, mean arterial pressure, central venous pressure, pulmonary artery pressure, and airway pressure did not change markedly during or after the shocks. Three premature ventricular contractions occurred in one animal; all other ECG results were normal. Conclusion: Repeated exposures to a conducted electrical weapon result in respiratory acidosis, metabolic vasodilation, and an increase in blood lactate level. These effects were transient in this study, with full recovery by 4 hours postexposure. The Stinger S-400 appears to have no serious adverse physiologic effects on healthy, anesthetized swine.
引用
收藏
页码:576 / 583
页数:8
相关论文
共 50 条
  • [31] A comparative brief on conducted electrical weapon safetyEine vergleichende Sicherheitsanalyse von Elektroschockdistanzwaffen
    Sebastian N. Kunz
    Jiri Adamec
    Wiener Medizinische Wochenschrift, 2019, 169 : 185 - 192
  • [32] SAFETY OF TRANSCARDIAC CONDUCTED ELECTRICAL WEAPON PROBE DEPLOYMENTS REMAINS UNCLEAR RESPONSE
    Bozeman, William P.
    Winslow, James E.
    Teacher, Eric
    JOURNAL OF EMERGENCY MEDICINE, 2014, 46 (04): : 535 - 535
  • [33] The neurocognitive effects of a conducted electrical weapon compared to high intensity interval training and alcohol intoxication - implications for Miranda and consent
    Dawes, D.
    Ho, J.
    Vincent, A. S.
    Nystrom, P.
    Driver, B.
    JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2018, 53 : 51 - 57
  • [34] Ultrasound measurement of cardiac activity during conducted electrical weapon application in exercising adults
    Ho, J. D.
    Reardon, R. F.
    Dawes, D. M.
    Johnson, M. A.
    ANNALS OF EMERGENCY MEDICINE, 2007, 50 (03) : S108 - S108
  • [35] A comparative study of conducted electrical weapon incapacitation during a goal-directed task
    Jeffrey Ho
    Donald M. Dawes
    Sebastian N. Kunz
    Rajesh Satpathy
    Lauren Klein
    Brian Driver
    Jamie L. Stang
    Forensic Science, Medicine and Pathology, 2020, 16 : 613 - 621
  • [36] A comparative study of conducted electrical weapon incapacitation during a goal-directed task
    Ho, Jeffrey
    Dawes, Donald M.
    Kunz, Sebastian N.
    Satpathy, Rajesh
    Klein, Lauren
    Driver, Brian
    Stang, Jamie L.
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2020, 16 (04) : 613 - 621
  • [37] Infection Risk From Conducted Electrical Weapon Probes: What Do We Know?
    Kroll, Mark W.
    Ritter, Mollie B.
    Guilbault, Richard A.
    Panescu, Dorin
    JOURNAL OF FORENSIC SCIENCES, 2016, 61 (06) : 1556 - 1562
  • [38] Physiological effects of the TASER® C2 conducted energy weapon
    James R. Jauchem
    Ronald L. Seaman
    Curtis M. Klages
    Forensic Science, Medicine, and Pathology, 2009, 5
  • [39] Physiological effects of the TASER® C2 conducted energy weapon
    James R. Jauchem
    Ronald L. Seaman
    Curtis M. Klages
    Forensic Science, Medicine, and Pathology, 2009, 5 : 330 - 330
  • [40] Physiological effects of the TASER® C2 conducted energy weapon
    Jauchem, James R.
    Seaman, Ronald L.
    Klages, Curtis M.
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2009, 5 (03) : 189 - 198