Parallel transmit pulse design for saturation homogeneity (PUSH) for magnetization transfer imaging at 7T

被引:9
|
作者
Leitao, David [1 ]
Tomi-Tricot, Raphael [2 ]
Bridgen, Pip [1 ]
Wilkinson, Tom [1 ]
Liebig, Patrick [3 ]
Gumbrecht, Rene [3 ]
Ritter, Dieter [3 ]
Giles, Sharon L. [1 ]
Baburamani, Ana [4 ]
Sedlacik, Jan [1 ,4 ]
Hajnal, Joseph, V [1 ,4 ]
Malik, Shaihan J. [1 ,4 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, Biomed Engn Dept, London, England
[2] Siemens Healthcare Ltd, MR Res Collaborat, Frimley, England
[3] Siemens Healthcare GmbH, Erlangen, Germany
[4] Kings Coll London, Ctr Developing Brain, Sch Biomed Engn & Imaging Sci, London, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
<mml; math altimg="urn; x-wiley; 07403194; media; mrm29199; mrm29199-math-0001" display="inline" overflow="scroll"><mml; mrow><mml; msubsup><mml; mi>B</mml; mi><mml; mn>1</mml; mn><mml; mo>+</mml; mo></mml; msubsup></mml; mrow></mml; math> inhomogeneity; magnetization transfer; parallel transmit; RF pulse design; ultrahigh-field; B-1(+) INHOMOGENEITY MITIGATION; HUMAN BRAIN; RF PULSES; RADIOFREQUENCY PULSE; FLIP-ANGLE; EXCITATION; OPTIMIZATION; EXCHANGE; SYSTEMS; MODEL;
D O I
10.1002/mrm.29199
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This work proposes a novel RF pulse design for parallel transmit (pTx) systems to obtain uniform saturation of semisolid magnetization for magnetization transfer (MT) contrast in the presence of transmit field ( B+ 1) inhomogeneities. The semisolid magnetization is usually modeled as being purely longitudinal, with the applied B+ 1 field saturating but not rotating its magnetization; thus, standard pTx pulse design methods do not apply. Theory and Methods: Pulse design for saturation homogeneity (PUSH) optimizes pTx RF pulses by considering uniformity of root-mean squared B+ 1, Brms 1, which relates to the rate of semisolid saturation. Here we considered designs consisting of a small number of spatially non-selective sub-pulses optimized over either a single 2Dplane or 3D. Simulations and in vivo experiments on a 7T Terra system with an 8-TX Nova head coil in five subjects were carried out to study the homogenization of Brms 1 and of the MT contrast by acquiring MT ratio maps. Results: Simulations and in vivo experiments showed up to six and two times more uniform Brms 1 compared to circular polarized (CP) mode for 2D and 3D optimizations, respectively. This translated into 4 and 1.25 times more uniform MT contrast, consistently for all subjects, where two sub-pulses were enough for the implementation and coil used. Conclusion: The proposed PUSHmethod obtainsmore uniform and higherMT contrast than CP mode within the same specific absorption rate (SAR) budget.
引用
收藏
页码:180 / 194
页数:15
相关论文
共 50 条
  • [41] Personalized local SAR prediction for parallel transmit neuroimaging at 7T from a single T1-weighted dataset
    Brink, Wyger M.
    Yousefi, Sahar
    Bhatnagar, Prernna
    Remis, Rob F.
    Staring, Marius
    Webb, Andrew G.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (01) : 464 - 475
  • [42] Amide proton transfer imaging of the human breast at 7T: development and reproducibility
    Klomp, Dennis W. J.
    Dula, Adrienne N.
    Arlinghaus, Lori R.
    Italiaander, Michel
    Dortch, Richard D.
    Zu, Zhongliang
    Williams, Jason M.
    Gochberg, Daniel F.
    Luijten, Peter R.
    Gore, John C.
    Yankeelov, Thomas E.
    Smith, Seth A.
    NMR IN BIOMEDICINE, 2013, 26 (10) : 1271 - 1277
  • [43] Simultaneous Multislice Imaging in Dynamic Cardiac MRI at 7T Using Parallel Transmission
    Schmitter, Sebastian
    Moeller, Steen
    Wu, Xiaoping
    Auerbach, Edward J.
    Metzger, Gregory J.
    Van de Moortele, Pierre-Francois
    Ugurbil, Kamil
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1010 - 1020
  • [44] Noninvasive Delineation of Glioma Infiltration with Combined 7T Chemical Exchange Saturation Transfer Imaging and MR Spectroscopy: A Diagnostic Accuracy Study
    Yuan, Yifan
    Yu, Yang
    Guo, Yu
    Chu, Yinghua
    Chang, Jun
    Hsu, Yicheng
    Liebig, Patrick Alexander
    Xiong, Ji
    Yu, Wenwen
    Feng, Danyang
    Yang, Baofeng
    Chen, Liang
    Wang, He
    Yue, Qi
    Mao, Ying
    METABOLITES, 2022, 12 (10)
  • [45] Evaluation of the whole auditory pathway using high-resolution and functional MRI at 7T parallel-transmit
    Da Costa, Sandra
    Clement, Jeremie
    Gruetter, Rolf
    Ipek, Ozlem
    PLOS ONE, 2021, 16 (09):
  • [46] Tailored and universal parallel transmit broadband pulses for homogeneous 3D excitation of the human heart at 7T
    Aigner, Christoph Stefan
    Dietrich-Conzelmann, Sebastian
    Lutz, Max
    Krueger, Felix
    Schmitter, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (02) : 730 - 740
  • [47] SAR Reduction in 7T C-Spine Imaging Using a "Dark Modes" Transmit Array Strategy
    Eryaman, Yigitcan
    Guerin, Bastien
    Keil, Boris
    Mareyam, Azma
    Herraiz, Joaquin L.
    Kosior, Robert K.
    Martin, Adrian
    Torrado-Carvajal, Angel
    Malpica, Norberto
    Hernandez-Tamames, Juan A.
    Schiavi, Emanuele
    Adalsteinsson, Elfar
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (04) : 1533 - 1539
  • [48] 7T quantitative magnetization transfer (qMT) of cortical gray matter in multiple sclerosis correlates with cognitive impairment
    McKeithan, Lydia J.
    Lyttle, Bailey D.
    Box, Bailey A.
    O'Grady, Kristin P.
    Dortch, Richard D.
    Conrad, Benjamin N.
    Thompson, Lindsey M.
    Rogers, Baxter P.
    Newhouse, Paul
    Pawate, Siddharama
    Bagnato, Francesca
    Smith, Seth A.
    NEUROIMAGE, 2019, 203
  • [49] A 16-Channel Receive, Forced Current Excitation Dual-Transmit Coil for Breast Imaging at 7T
    By, Samantha
    Rispoli, Joseph V.
    Cheshkov, Sergey
    Dimitrov, Ivan
    Cui, Jiaming
    Seiler, Stephen
    Goudreau, Sally
    Malloy, Craig
    Wright, Steven M.
    McDougall, Mary Preston
    PLOS ONE, 2014, 9 (11):
  • [50] One-Dimensional Image-Selected In Vivo Spectroscopy Localized Phosphorus Saturation Transfer at 7T
    Valkovic, Ladislav
    Bogner, Wolfgang
    Gajdosik, Martin
    Povazan, Michal
    Kukurova, Ivica Just
    Krssak, Martin
    Gruber, Stephan
    Frollo, Ivan
    Trattnig, Siegfried
    Chmelik, Marek
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (06) : 1509 - 1515