Parallel transmit pulse design for saturation homogeneity (PUSH) for magnetization transfer imaging at 7T

被引:9
|
作者
Leitao, David [1 ]
Tomi-Tricot, Raphael [2 ]
Bridgen, Pip [1 ]
Wilkinson, Tom [1 ]
Liebig, Patrick [3 ]
Gumbrecht, Rene [3 ]
Ritter, Dieter [3 ]
Giles, Sharon L. [1 ]
Baburamani, Ana [4 ]
Sedlacik, Jan [1 ,4 ]
Hajnal, Joseph, V [1 ,4 ]
Malik, Shaihan J. [1 ,4 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, Biomed Engn Dept, London, England
[2] Siemens Healthcare Ltd, MR Res Collaborat, Frimley, England
[3] Siemens Healthcare GmbH, Erlangen, Germany
[4] Kings Coll London, Ctr Developing Brain, Sch Biomed Engn & Imaging Sci, London, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
<mml; math altimg="urn; x-wiley; 07403194; media; mrm29199; mrm29199-math-0001" display="inline" overflow="scroll"><mml; mrow><mml; msubsup><mml; mi>B</mml; mi><mml; mn>1</mml; mn><mml; mo>+</mml; mo></mml; msubsup></mml; mrow></mml; math> inhomogeneity; magnetization transfer; parallel transmit; RF pulse design; ultrahigh-field; B-1(+) INHOMOGENEITY MITIGATION; HUMAN BRAIN; RF PULSES; RADIOFREQUENCY PULSE; FLIP-ANGLE; EXCITATION; OPTIMIZATION; EXCHANGE; SYSTEMS; MODEL;
D O I
10.1002/mrm.29199
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This work proposes a novel RF pulse design for parallel transmit (pTx) systems to obtain uniform saturation of semisolid magnetization for magnetization transfer (MT) contrast in the presence of transmit field ( B+ 1) inhomogeneities. The semisolid magnetization is usually modeled as being purely longitudinal, with the applied B+ 1 field saturating but not rotating its magnetization; thus, standard pTx pulse design methods do not apply. Theory and Methods: Pulse design for saturation homogeneity (PUSH) optimizes pTx RF pulses by considering uniformity of root-mean squared B+ 1, Brms 1, which relates to the rate of semisolid saturation. Here we considered designs consisting of a small number of spatially non-selective sub-pulses optimized over either a single 2Dplane or 3D. Simulations and in vivo experiments on a 7T Terra system with an 8-TX Nova head coil in five subjects were carried out to study the homogenization of Brms 1 and of the MT contrast by acquiring MT ratio maps. Results: Simulations and in vivo experiments showed up to six and two times more uniform Brms 1 compared to circular polarized (CP) mode for 2D and 3D optimizations, respectively. This translated into 4 and 1.25 times more uniform MT contrast, consistently for all subjects, where two sub-pulses were enough for the implementation and coil used. Conclusion: The proposed PUSHmethod obtainsmore uniform and higherMT contrast than CP mode within the same specific absorption rate (SAR) budget.
引用
收藏
页码:180 / 194
页数:15
相关论文
共 50 条
  • [21] Broadband Transmit/Receive Switch for 3T and 7T Magnetic Resonance Imaging
    Abuelhaija, Ashraf
    Saleh, Gameel
    Salama, Sanaa
    Hamdan, Mohammed
    JOURNAL OF ELECTROMAGNETIC ENGINEERING AND SCIENCE, 2024, 24 (03): : 243 - 253
  • [22] Mapping magnetization transfer saturation (MTsat) in human brain at 7T: Protocol optimization under specific absorption rate constraints
    Olsson, Hampus
    Andersen, Mads
    Wirestam, Ronnie
    Helms, Gunther
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (05) : 2562 - 2576
  • [23] B1+$$ {B}_1∧{+} $$-correction of magnetization transfer saturation maps optimized for 7T postmortem MRI of the brain
    Lipp, Ilona
    Kirilina, Evgeniya
    Edwards, Luke J.
    Pine, Kerrin J.
    Jaeger, Carsten
    Graessle, Tobias
    Weiskopf, Nikolaus
    Helms, Gunther
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) : 1385 - 1400
  • [24] Parallel transmission 2D RARE imaging at 7T with transmit field inhomogeneity mitigation and local SAR control
    Yetisir, Filiz
    Poser, Benedikt A.
    Grant, P. Ellen
    Adalsteinsson, Elfar
    Wald, Lawrence L.
    Guerin, Bastien
    MAGNETIC RESONANCE IMAGING, 2022, 93 : 87 - 96
  • [25] Relaxation-compensated CEST (chemical exchange saturation transfer) imaging in breast cancer diagnostics at 7T
    Loi, Lisa
    Zimmermann, Ferdinand
    Goerke, Steffen
    Korzowski, Andreas
    Meissner, Jan-Eric
    Deike-Hofmann, Katerina
    Stieber, Anne
    Bachert, Peter
    Ladd, Mark Edward
    Schlemmer, Heinz-Peter
    Bickelhaupt, Sebastian
    Schott, Sarah
    Paech, Daniel
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 129
  • [26] Cardiac gating using scattering of an 8-channel parallel transmit coil at 7T
    Jaeschke, Sven H. F.
    Robson, Matthew D.
    Hess, Aaron T.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 633 - 640
  • [27] High-resolution in vivo imaging of human locus coeruleus by magnetization transfer MRI at 3T and 7T
    Priovoulos, Nikos
    Jacobs, Heidi I. L.
    Ivanov, Dimo
    Uludag, Kamil
    Verhey, Frans R. J.
    Poser, Benedikt A.
    NEUROIMAGE, 2018, 168 : 427 - 436
  • [28] Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T
    Xinqiang Yan
    Xiaoliang Zhang
    Long Wei
    Rong Xue
    Applied Magnetic Resonance, 2015, 46 : 59 - 66
  • [29] Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T
    Yan, Xinqiang
    Zhang, Xiaoliang
    Wei, Long
    Xue, Rong
    APPLIED MAGNETIC RESONANCE, 2015, 46 (01) : 59 - 66
  • [30] A highly decoupled transmit-receive array design with triangular elements at 7T
    Chen, Gang
    Zhang, Bei
    Cloos, Martijn A.
    Sodickson, Daniel K.
    Wiggins, Graham C.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 2267 - 2274