Parallel transmit pulse design for saturation homogeneity (PUSH) for magnetization transfer imaging at 7T

被引:9
|
作者
Leitao, David [1 ]
Tomi-Tricot, Raphael [2 ]
Bridgen, Pip [1 ]
Wilkinson, Tom [1 ]
Liebig, Patrick [3 ]
Gumbrecht, Rene [3 ]
Ritter, Dieter [3 ]
Giles, Sharon L. [1 ]
Baburamani, Ana [4 ]
Sedlacik, Jan [1 ,4 ]
Hajnal, Joseph, V [1 ,4 ]
Malik, Shaihan J. [1 ,4 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, Biomed Engn Dept, London, England
[2] Siemens Healthcare Ltd, MR Res Collaborat, Frimley, England
[3] Siemens Healthcare GmbH, Erlangen, Germany
[4] Kings Coll London, Ctr Developing Brain, Sch Biomed Engn & Imaging Sci, London, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
<mml; math altimg="urn; x-wiley; 07403194; media; mrm29199; mrm29199-math-0001" display="inline" overflow="scroll"><mml; mrow><mml; msubsup><mml; mi>B</mml; mi><mml; mn>1</mml; mn><mml; mo>+</mml; mo></mml; msubsup></mml; mrow></mml; math> inhomogeneity; magnetization transfer; parallel transmit; RF pulse design; ultrahigh-field; B-1(+) INHOMOGENEITY MITIGATION; HUMAN BRAIN; RF PULSES; RADIOFREQUENCY PULSE; FLIP-ANGLE; EXCITATION; OPTIMIZATION; EXCHANGE; SYSTEMS; MODEL;
D O I
10.1002/mrm.29199
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This work proposes a novel RF pulse design for parallel transmit (pTx) systems to obtain uniform saturation of semisolid magnetization for magnetization transfer (MT) contrast in the presence of transmit field ( B+ 1) inhomogeneities. The semisolid magnetization is usually modeled as being purely longitudinal, with the applied B+ 1 field saturating but not rotating its magnetization; thus, standard pTx pulse design methods do not apply. Theory and Methods: Pulse design for saturation homogeneity (PUSH) optimizes pTx RF pulses by considering uniformity of root-mean squared B+ 1, Brms 1, which relates to the rate of semisolid saturation. Here we considered designs consisting of a small number of spatially non-selective sub-pulses optimized over either a single 2Dplane or 3D. Simulations and in vivo experiments on a 7T Terra system with an 8-TX Nova head coil in five subjects were carried out to study the homogenization of Brms 1 and of the MT contrast by acquiring MT ratio maps. Results: Simulations and in vivo experiments showed up to six and two times more uniform Brms 1 compared to circular polarized (CP) mode for 2D and 3D optimizations, respectively. This translated into 4 and 1.25 times more uniform MT contrast, consistently for all subjects, where two sub-pulses were enough for the implementation and coil used. Conclusion: The proposed PUSHmethod obtainsmore uniform and higherMT contrast than CP mode within the same specific absorption rate (SAR) budget.
引用
收藏
页码:180 / 194
页数:15
相关论文
共 50 条
  • [31] Design of a forward view antenna for prostate imaging at 7T
    Steensma, Bart R.
    Voogt, Ingmar
    van der Werf, Abe J.
    van den Berg, Cornelis A. T.
    Luijten, Peter R.
    Klomp, Dennis W. J.
    Raaijmakers, Alexander J. E.
    NMR IN BIOMEDICINE, 2018, 31 (09)
  • [32] Detection of the Presence and Myelination Status of Cortical Lesions Using 7T Magnetization Transfer Imaging in Patients with Multiple Sclerosis
    Abdel-Fahim, Rasha
    Mistry, Niraj
    Mougin, Olivier
    Gowland, Penny
    Pitiot, Alain
    Evangelou, Nikos
    NEUROLOGY, 2013, 80
  • [33] Aberrant myelination of the cingulum and Schneiderian delusions in schizophrenia: a 7T magnetization transfer study
    Palaniyappan, Lena
    Al-Radaideh, Ali
    Mougin, Olivier
    Das, Tushar
    Gowland, Penny
    Liddle, Peter F.
    PSYCHOLOGICAL MEDICINE, 2019, 49 (11) : 1890 - 1896
  • [34] 7T Transmit/Receive Arrays Using ICE Decoupling for Human Head MR Imaging
    Yan, Xinqiang
    Zhang, Xiaoliang
    Feng, Baotong
    Ma, ChuangXin
    Wei, Long
    Xue, Rong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (09) : 1781 - 1787
  • [35] Fast Magnetization Transfer and Apparent T1 Imaging Using a Short Saturation Pulse with and without Inversion Preparation
    Kim, Tae
    Shin, Wanyong
    Kim, Seong-Gi
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 1264 - 1271
  • [36] Sodium imaging of the heart at 7T: design, evaluation and application of a four-channel transmit/receive surface coil array
    A Graessl
    A Ruehle
    W Renz
    L Winter
    H Pfeiffer
    J Ruff
    J Rieger
    T Niendorf
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [37] Selective homonuclear polarization transfer for spectroscopic imaging of GABA at 7T
    Pan, J. W.
    Duckrow, R. B.
    Spencer, D. D.
    Avdievich, N. I.
    Hetherington, H. P.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (02) : 310 - 316
  • [38] Quantitative magnetization transfer imaging of human brain at 7 T
    Dortch, Richard D.
    Moore, Jay
    Li, Ke
    Jankiewicz, Marcin
    Gochberg, Daniel F.
    Hirtle, Jane A.
    Gore, John C.
    Smith, Seth A.
    NEUROIMAGE, 2013, 64 : 640 - 649
  • [39] Advancing 7T perfusion imaging by pulsed arterial spin labeling: Using a parallel transmit coil for enhanced labeling robustness and temporal SNR
    Oliveira, Icaro Agenor Ferreira
    Schnabel, Robin
    van Osch, Matthias J. P.
    van der Zwaag, Wietske
    Hirschler, Lydiane
    PLOS ONE, 2024, 19 (08):
  • [40] Variable density magnetization transfer (vdMT) imaging for 7 T MR imaging
    Oh, Se-Hong
    Shin, Wanyong
    Lee, Jongho
    Lowe, Mark J.
    NEUROIMAGE, 2018, 168 : 242 - 249