Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

被引:17
|
作者
Park, Hee Jin [1 ]
Lee, So Yeon [1 ]
Rho, Myung Ho [1 ]
Chung, Eun Chul [1 ]
Kim, Mi Sung [1 ]
Kwon, Heon Ju [1 ]
Youn, In Young [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Radiol, 29 Saemunan Ro, Seoul 03181, South Korea
关键词
MR; Diffusion; Spine; Fractures; Compression; DWI; ADC; BONE-MARROW; LESIONS; SPINE;
D O I
10.3348/kjr.2016.17.5.590
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. Materials and Methods: A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. Results: The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. Conclusion: The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.
引用
收藏
页码:590 / 597
页数:8
相关论文
共 50 条
  • [31] Diffusion tensor imaging focusing on lower cervical spinal cord using 2D reduced FOV interleaved multislice single-shot diffusion-weighted echo-planar imaging: comparison with conventional single-shot diffusion-weighted echo-planar imaging
    Park, Eun Hae
    Lee, Young Han
    Jeong, Eun-Kee
    Roh, Yun Ho
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2015, 33 (04) : 401 - 406
  • [32] Characterization of focal hepatic lesions on diffusion-weighted MR imaging: Comparison between single-shot echo-planar imaging and single shot fast spin-echo sequence
    Ohgiya, Y
    Gokan, T
    Nobusawa, H
    Hirose, M
    Seino, N
    Munechika, H
    RADIOLOGY, 2001, 221 : 108 - 108
  • [33] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [34] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    He An
    Xiaodong Ma
    Ziyi Pan
    Hua Guo
    Elaine Yuen Phin Lee
    European Radiology, 2020, 30 : 1876 - 1884
  • [35] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    An, He
    Ma, Xiaodong
    Pan, Ziyi
    Guo, Hua
    Lee, Elaine Yuen Phin
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 1876 - 1884
  • [36] High-Resolution Diffusion-Weighted Imaging of Neck Lymph Nodes Using 2D-Single-Shot Interleaved Multiple Inner Volume Imaging Diffusion-Weighted Echo-Planar Imaging at 3T
    Park, J. K.
    Kim, S. -E.
    Trieman, G. S.
    Parker, D.
    Jeong, E. -K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) : 1173 - 1177
  • [37] Hemorrhagic and nonhemorrhagic stroke: Diagnosis with diffusion-weighted and T2-weighted echo-planar MR imaging
    Ebisu, T
    Tanaka, C
    Umeda, M
    Kitamura, M
    Fukunaga, M
    Aoki, I
    Sato, H
    Higuchi, T
    Naruse, S
    Horikawa, Y
    Ueda, S
    RADIOLOGY, 1997, 203 (03) : 823 - 828
  • [38] Evaluation of Thin-slice Coronal Single-shot Turbo Spin-echo Diffusion-weighted Imaging of the Hand: A Comparison with Conventional Echo-planar Diffusion-weighted Imaging
    Ogawa, Masaki
    Nakagawa, Motoo
    Arai, Nobuyuki
    Kan, Hirohito
    Ohba, Shota
    Shibata, Shunsuke
    Maki, Hiroyuki
    Shibamoto, Yuta
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (04) : 382 - 388
  • [39] T2-weighted prostate imaging using echo-planar imaging at 3T
    Ragan, D
    Ma, J
    MEDICAL PHYSICS, 2005, 32 (06) : 1911 - 1911
  • [40] Zoomed echo-planar imaging using parallel transmission: impact on image quality of diffusion-weighted imaging of the prostate at 3T
    Andrew B. Rosenkrantz
    Hersh Chandarana
    Josef Pfeuffer
    Michael J. Triolo
    Mohammed Bilal Shaikh
    David J. Mossa
    Christian Geppert
    Abdominal Imaging, 2015, 40 : 120 - 126