Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

被引:17
|
作者
Park, Hee Jin [1 ]
Lee, So Yeon [1 ]
Rho, Myung Ho [1 ]
Chung, Eun Chul [1 ]
Kim, Mi Sung [1 ]
Kwon, Heon Ju [1 ]
Youn, In Young [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Radiol, 29 Saemunan Ro, Seoul 03181, South Korea
关键词
MR; Diffusion; Spine; Fractures; Compression; DWI; ADC; BONE-MARROW; LESIONS; SPINE;
D O I
10.3348/kjr.2016.17.5.590
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. Materials and Methods: A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. Results: The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. Conclusion: The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.
引用
收藏
页码:590 / 597
页数:8
相关论文
共 50 条
  • [41] Zoomed echo-planar imaging using parallel transmission: impact on image quality of diffusion-weighted imaging of the prostate at 3T
    Rosenkrantz, Andrew B.
    Chandarana, Hersh
    Pfeuffer, Josef
    Triolo, Michael J.
    Shaikh, Mohammed Bilal
    Mossa, David J.
    Geppert, Christian
    ABDOMINAL IMAGING, 2015, 40 (01): : 120 - 126
  • [42] Clinically relevant rat model for testing BOLD functional MR imaging techniques by using single-shot echo-planar imaging at 1.5 T
    Morton, DW
    Maravilla, KR
    Meno, JR
    Winn, HR
    RADIOLOGY, 2001, 218 (02) : 598 - 601
  • [43] High resolution diffusion weighted magnetic resonance imaging of the pancreas using reduced field of view single-shot echo-planar imaging at 3 T
    Ma, Chao
    Li, Yan-jun
    Pan, Chun-shu
    Wang, He
    Wang, Jian
    Chen, Shi-yue
    Lu, Jian-ping
    MAGNETIC RESONANCE IMAGING, 2014, 32 (02) : 125 - 131
  • [44] Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique
    Bruegel, Melanie
    Holzapfel, Konstantin
    Gaa, Jochen
    Woertler, Klaus
    Waldt, Simone
    Kiefer, Berthold
    Stemmer, Alto
    Ganter, Carl
    Rummeny, Ernst J.
    EUROPEAN RADIOLOGY, 2008, 18 (03) : 477 - 485
  • [45] Single-shot diffusion-weighted echo-planar imaging of normal and cirrhotic livers using a phased-array multicoil
    Amano, Y
    Kumazaki, T
    Ishihara, M
    ACTA RADIOLOGICA, 1998, 39 (04) : 440 - 442
  • [46] Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique
    Melanie Bruegel
    Konstantin Holzapfel
    Jochen Gaa
    Klaus Woertler
    Simone Waldt
    Berthold Kiefer
    Alto Stemmer
    Carl Ganter
    Ernst J. Rummeny
    European Radiology, 2008, 18 : 477 - 485
  • [47] Diffusion-Weighted Imaging of the Abdomen: Comparing Artifacts in Different Techniques Using 1.5T and 3T Magnets
    Jalili, M.
    Sefidbakht, S.
    Quane, L.
    Saremi, F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [48] Readout-segmented echo-planar diffusion-weighted imaging in the assessment of orbital tumors: comparison with conventional single-shot echo-planar imaging in image quality and diagnostic performance
    Xu, Xiaoquan
    Wang, Yanjun
    Hu, Hao
    Su, Guoyi
    Liu, Hu
    Shi, Haibin
    Wu, Feiyun
    ACTA RADIOLOGICA, 2017, 58 (12) : 1457 - 1467
  • [49] Multiplexed sensitivity-encoding versus single-shot echo-planar imaging: a comparative study for diffusion-weighted imaging of the thyroid lesions
    Xiuyu Wang
    Peng Wang
    Heng Zhang
    Xian Wang
    Jie Shi
    Shudong Hu
    Japanese Journal of Radiology, 2024, 42 : 268 - 275
  • [50] Prospective Comparison of FOCUS MUSE and Single-Shot Echo-Planar Imaging for Diffusion-Weighted Imaging in Evaluating Thyroid-Associated Ophthalmopathy
    Wang, YunMeng
    Cui, YuanYuan
    Dai, JianKun
    Ni, ShuangShuang
    Zhang, TianRan
    Chen, Xin
    Jiang, QinLing
    Cheng, YuXin
    Ma, YiChuan
    Li, Tuo
    Xiao, Yi
    KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (10) : 913 - 923