Stereotactic radiotherapy for lung cancer using flattening filter free accelerator

被引:1
|
作者
Vassiliev, O. [1 ]
Kry, S. [1 ]
Chang, J. [1 ]
Balter, P. [1 ]
Titt, U. [1 ]
Mohan, R. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.2761112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of stereotactic radiation therapy for lung cancer using photon beams from an accelerator operated without a flattening filter. To determine potential benefits and drawback of using unflattened beams for this type of treatment. Methods and Materials: Treatment plans were generated for 10 lung cancer patients with small, less than 3 cm diameter, isolated lesions using a dose prescription of 12.5 Gy/fx, the standard for these treatments in our clinic. Plans were generated with Eclipse 8.0 (Varian Medical Systems) commissioned with beam data measured on a Clinac 21EX (Varian Medical Systems) operated with and without the flattening filter. For each patient two plans were generated, one with and one without the flattening filter. All patients were forward planned using wedges and/or static multuleaf collimator with one or two segments per field. Results: Removal of the flattening filter increased the dose rate. For 6 MV beams the total beam‐on time per plan was lower by a factor of 2.31±0.02 in plans with unflattened beams. The median beam‐on time per field was reduced from 37s with the filter to 15s without one, suggesting the feasibility of breath‐hold treatments with unflattened beams for a majority of patients. These comparisons were made assuming the same current of electrons incident on the bremsstrahlung target. The median difference between maximum and minimum doses in the planning target volume divided by the mean target dose was 0.21 with, and 0.22 without the filter. Differences in doses to organs at risk were within approximately ±10 cGy without significant advantage of one modality over another. Conclusion: Dose distributions in treatment plans with unflattened beam were close to those achieved with flattened beams, but required substantially lower beam‐on time, increasing the feasibility of breath‐hold gated treatments. Conflict of Interest: Research is sponsored by Varian Medical Systems. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2491 / 2491
页数:1
相关论文
共 50 条
  • [41] Stereotactic body radiotherapy with flattening filter-free beams for prostate cancer: assessment of patient-reported quality of life
    Scorsetti, Marta
    Alongi, Filippo
    Clerici, Elena
    Comito, Tiziana
    Fogliata, Antonella
    Iftode, Cristina
    Mancosu, Pietro
    Navarria, Piera
    Reggiori, Giacomo
    Tomatis, Stefano
    Villa, Elisa
    Cozzi, Luca
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2014, 140 (10) : 1795 - 1800
  • [42] Stereotactic body radiotherapy with flattening filter-free beams for prostate cancer: assessment of patient-reported quality of life
    Marta Scorsetti
    Filippo Alongi
    Elena Clerici
    Tiziana Comito
    Antonella Fogliata
    Cristina Iftode
    Pietro Mancosu
    Piera Navarria
    Giacomo Reggiori
    Stefano Tomatis
    Elisa Villa
    Luca Cozzi
    Journal of Cancer Research and Clinical Oncology, 2014, 140 : 1795 - 1800
  • [43] Dosimetric evaluation of different planning techniques based on flattening filter-free beams for central and peripheral lung stereotactic body radiotherapy
    Dwivedi, Shekhar
    Kansal, Sandeep
    Shukla, Jooli
    Bharati, Avinav
    Dangwal, Vinod Kumar
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (06)
  • [44] A treatment planning study of liver cancer treatments with a flattening filter free linear accelerator
    Vassiliev, O.
    Beddar, A.
    Krishnan, S.
    Briere, T.
    Gillin, M.
    Mohan, R.
    Titt, U.
    MEDICAL PHYSICS, 2006, 33 (06) : 2064 - 2065
  • [45] Comparison of VMAT for single fraction lung cancer radiotherapy with and without flattening filter
    Barbiero, S.
    Matteucci, F.
    Fedele, D.
    Avanzo, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S776 - S776
  • [46] Dosimetric Comparison of Volumetric Modulated Arc Therapy Plans for Preoperative Radiotherapy Rectal Cancer Using Flattening Filter-Free and Flattening Filter Modes
    Zhang, W.
    Zhang, J.
    Lu, J.
    Chen, C.
    MEDICAL PHYSICS, 2015, 42 (06) : 3404 - 3404
  • [47] Identification of the suitable leaf margin for liver stereotactic body radiotherapy with flattening filter-free beams
    Ogata, Toshiyuki
    Nishimura, Hideki
    Mayahara, Hiroshi
    Uehara, Kazuyuki
    Okayama, Takanobu
    MEDICAL DOSIMETRY, 2017, 42 (04) : 268 - 272
  • [48] Flattening Filter Free vs. Flattened Beams for Lung Stereotactic Body Radiation Therapy
    Annede, Pierre
    Darreon, Julien
    Benkemouche, Ahcene
    Valdenaire, Simon
    Tyran, Marguerite
    Kaeppelin, Bertrand
    Macagno, Alban
    Barrou, Julien
    Cagetti, Leonel Varela
    Favrel, Veronique
    Moureau-Zabotto, Laurence
    Gonzague, Laurence
    Fau, Pierre
    Chargari, Cyrus
    Tallet, Agnes
    Salem, Naji
    ANTICANCER RESEARCH, 2017, 37 (09) : 5133 - 5139
  • [49] Melatonin as a radioprotective agent against flattening filter and flattening filter-free beam in radiotherapy-induced lung tissue damage
    Ozer Simsek, Zuhal
    Aras, Serhat
    Cikrikcioglu, Makbule
    Baydili, Kursad Nuri
    Cortuk, Mustafa
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2025, 101 (01) : 28 - 34
  • [50] Flattening filter free stereotactic body radiation therapy for lung tumors: outcomes and predictive factors
    Jaruthien, Thitiporn
    Kitpanit, Sarin
    Kannarunimit, Danita
    Nantavithya, Chonnipa
    Prayongrat, Anussara
    Alisanant, Petch
    Saksornchai, Kitwadee
    Amornwichet, Napapat
    Raiyava, Tassapong
    Chakkabat, Chakkapong
    Lertbutsayanukul, Chawalit
    Khorprasert, Chonlakiet
    Shotelersuk, Kanjana
    TRANSLATIONAL CANCER RESEARCH, 2021, 10 (02) : 571 - 580