Stereotactic radiotherapy for lung cancer using flattening filter free accelerator

被引:1
|
作者
Vassiliev, O. [1 ]
Kry, S. [1 ]
Chang, J. [1 ]
Balter, P. [1 ]
Titt, U. [1 ]
Mohan, R. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.2761112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of stereotactic radiation therapy for lung cancer using photon beams from an accelerator operated without a flattening filter. To determine potential benefits and drawback of using unflattened beams for this type of treatment. Methods and Materials: Treatment plans were generated for 10 lung cancer patients with small, less than 3 cm diameter, isolated lesions using a dose prescription of 12.5 Gy/fx, the standard for these treatments in our clinic. Plans were generated with Eclipse 8.0 (Varian Medical Systems) commissioned with beam data measured on a Clinac 21EX (Varian Medical Systems) operated with and without the flattening filter. For each patient two plans were generated, one with and one without the flattening filter. All patients were forward planned using wedges and/or static multuleaf collimator with one or two segments per field. Results: Removal of the flattening filter increased the dose rate. For 6 MV beams the total beam‐on time per plan was lower by a factor of 2.31±0.02 in plans with unflattened beams. The median beam‐on time per field was reduced from 37s with the filter to 15s without one, suggesting the feasibility of breath‐hold treatments with unflattened beams for a majority of patients. These comparisons were made assuming the same current of electrons incident on the bremsstrahlung target. The median difference between maximum and minimum doses in the planning target volume divided by the mean target dose was 0.21 with, and 0.22 without the filter. Differences in doses to organs at risk were within approximately ±10 cGy without significant advantage of one modality over another. Conclusion: Dose distributions in treatment plans with unflattened beam were close to those achieved with flattened beams, but required substantially lower beam‐on time, increasing the feasibility of breath‐hold gated treatments. Conflict of Interest: Research is sponsored by Varian Medical Systems. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2491 / 2491
页数:1
相关论文
共 50 条
  • [31] A dosimetric and treatment efficiency evaluation of stereotactic body radiation therapy for peripheral lung cancer using flattening filter free beams
    Zhang, Ji-Yong
    Lu, Jia-Yang
    Wu, Li-Li
    Hong, Dan-Li
    Ma, Chang-chun
    Peng, Xun
    Lin, Zhi-Xiong
    ONCOTARGET, 2016, 7 (45) : 73792 - 73799
  • [32] Dosimetric verification of stereotactic body radiation therapy for lung cancer treatment plans using flattening filter-free beams
    Zhang, Jiyong
    Wu, Vincent W.
    Lu, Jiayang
    Hong, Danli
    Lin, Zhixiong
    TUMORI JOURNAL, 2015, 101 (06): : 631 - 636
  • [33] Dosimetric comparison of deep inspiration breath hold and free breathing technique in stereotactic body radiotherapy for localized lung tumor using Flattening Filter Free beam
    Mani, Karthick Raj
    Bhuiyan, Md. Anisuzzaman
    Alam, Md. Mahbub
    Ahmed, Sharif
    Sumon, Mostafa Aziz
    Sengupta, Ashim Kumar
    Rahman, Md. Shakilur
    Islam, Md. S. M. Azharul
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2018, 24 (01): : 15 - 24
  • [34] Stereotactic body radiation therapy for prostate cancer: a dosimetric comparison of IMRT and VMAT using flattening filter and flattening filter-free beams
    El-Sayed, Sherif M.
    El-Gebaly, Reem H.
    Fathy, Mohamed M.
    Abdelaziz, Dina M.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (03) : 423 - 431
  • [35] The comparison of properties for radiotherapy with flattening filter-free and flattening filter beam
    Gu, J. H.
    Won, H. S.
    Hong, J. W.
    Chang, N. J.
    Park, J. H.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S978 - S978
  • [36] Treatment planning study of prostate cancer IMRT with a flattening filter free accelerator
    Kry, S.
    Vassiliev, O.
    Kuban, D.
    Poenisch, F.
    Salehpour, M.
    Gillin, M.
    Mohan, R.
    Titt, U.
    MEDICAL PHYSICS, 2006, 33 (06) : 2146 - 2146
  • [37] FLATTENING FILTER FREE BEAMS FOR HYPOFRACTIONATED RADIOTHERAPY OF LOCALIZED PROSTATE CANCER
    Lang, S.
    Hrbacek, J.
    Najafi, Y.
    Streller, T.
    Klock, S.
    Studer, G.
    Zaugg, K.
    Luetolf, U. M.
    Zwahlen, D.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S188 - S189
  • [38] An assessment of the ExacTrac intrafraction imaging capabilities for flattening filter free prostate stereotactic body radiotherapy
    James Rijken
    Mark Sidhom
    Physical and Engineering Sciences in Medicine, 2020, 43 : 849 - 855
  • [39] An assessment of the ExacTrac intrafraction imaging capabilities for flattening filter free prostate stereotactic body radiotherapy
    Rijken, James
    Sidhom, Mark
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (03) : 849 - 855
  • [40] Investigating flattening filter free mode for peripheral lung stereotactic body radiation therapy
    Jensen, Michael
    Garcia, Lourdes M.
    Scora, Daryl
    Vandermeer, Aaron
    MEDICAL PHYSICS, 2017, 44 (08) : 4378 - 4378