Stereotactic radiotherapy for lung cancer using flattening filter free accelerator

被引:1
|
作者
Vassiliev, O. [1 ]
Kry, S. [1 ]
Chang, J. [1 ]
Balter, P. [1 ]
Titt, U. [1 ]
Mohan, R. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.2761112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of stereotactic radiation therapy for lung cancer using photon beams from an accelerator operated without a flattening filter. To determine potential benefits and drawback of using unflattened beams for this type of treatment. Methods and Materials: Treatment plans were generated for 10 lung cancer patients with small, less than 3 cm diameter, isolated lesions using a dose prescription of 12.5 Gy/fx, the standard for these treatments in our clinic. Plans were generated with Eclipse 8.0 (Varian Medical Systems) commissioned with beam data measured on a Clinac 21EX (Varian Medical Systems) operated with and without the flattening filter. For each patient two plans were generated, one with and one without the flattening filter. All patients were forward planned using wedges and/or static multuleaf collimator with one or two segments per field. Results: Removal of the flattening filter increased the dose rate. For 6 MV beams the total beam‐on time per plan was lower by a factor of 2.31±0.02 in plans with unflattened beams. The median beam‐on time per field was reduced from 37s with the filter to 15s without one, suggesting the feasibility of breath‐hold treatments with unflattened beams for a majority of patients. These comparisons were made assuming the same current of electrons incident on the bremsstrahlung target. The median difference between maximum and minimum doses in the planning target volume divided by the mean target dose was 0.21 with, and 0.22 without the filter. Differences in doses to organs at risk were within approximately ±10 cGy without significant advantage of one modality over another. Conclusion: Dose distributions in treatment plans with unflattened beam were close to those achieved with flattened beams, but required substantially lower beam‐on time, increasing the feasibility of breath‐hold gated treatments. Conflict of Interest: Research is sponsored by Varian Medical Systems. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2491 / 2491
页数:1
相关论文
共 50 条
  • [21] Parenchymal lung changes on computed tomography after stereotactic radiotherapy using high dose rate flattening filter free beams
    Dahele, Max
    de Koste, John R. van Sornsen
    van de Ven, Peter M.
    Spoelstra, Femke
    Ben Slotman
    Senan, Suresh
    RADIOTHERAPY AND ONCOLOGY, 2015, 114 (03) : 357 - 360
  • [22] Flattening Filter Free Dynamic Conformal Arcs for Lung Radiotherapy
    Pursley, J.
    Wiant, D.
    Terrell, J.
    Sintay, B.
    MEDICAL PHYSICS, 2012, 39 (06) : 3853 - 3853
  • [23] Late toxicity of prostate stereotactic ablative radiotherapy treated with flattening filter free
    Duffton, A.
    Devlin, L.
    Sadozye, A.
    McLoone, P.
    MacLeod, N.
    Lamb, C.
    Currie, S.
    Dodds, D.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S51 - S51
  • [24] Implementation and validation of Pinnacle for stereotactic body radiotherapy with a flattening filter free linac
    Krayenbuehl, J.
    Loewenich, K.
    Norton, I.
    Zamburlini, M.
    Riesterer, O.
    Kloeck, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (12) : 1090 - 1090
  • [25] Role of Volumetric-Modulated Arc Therapy with Flattening Filter Free Delivery in Lung Stereotactic Body Radiotherapy
    Liu, Hong-Wei
    Olivotto, Ivo
    Lau, Harold
    Nugent, Zoann
    Khan, Rao
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2016, 47 (02) : 155 - 159
  • [26] Improved Clinical Efficiency in CNS Stereotactic Radiosurgery (SRS) Using a Flattening Filter Free (FFF) Linear Accelerator
    Prendergast, B. M.
    Popple, R. A.
    Clark, G. M.
    Guthrie, B.
    Fiveash, J. B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S903 - S904
  • [27] FLATTENING FILTER FREE BEAMS FOR HYPOFRACTIONATED RADIOTHERAPY OF PROSTATE CANCER
    Zwahlen, D.
    Lang, S.
    Hrbacek, J.
    Najafi, Y.
    Streller, T.
    Kloeck, S.
    Studer, G.
    Zaugg, K.
    Luetolf, U.
    Glanzmann, G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (08) : 518 - 518
  • [28] Radiotherapy with a flattening filter free clinac
    Vassiliev, O. N.
    Kry, S. F.
    Mohan, R.
    Titt, U.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S704 - S704
  • [29] Progress and prospects of flattening filter free beam technology in radiosurgery and stereotactic body radiotherapy
    Ghemis, Diana M.
    Marcu, Loredana G.
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2021, 163
  • [30] Commissioning Measurements of Flattening Filter and Flattening Filter Free Photon Beams Using a TrueBeam Stx® Linear Accelerator
    Saidi K.
    El Baydaoui R.
    El Gouach H.
    Mesradi M.R.
    Naim A.
    Iranian Journal of Medical Physics, 2021, 18 (01) : 49 - 62