Stereotactic radiotherapy for lung cancer using flattening filter free accelerator

被引:1
|
作者
Vassiliev, O. [1 ]
Kry, S. [1 ]
Chang, J. [1 ]
Balter, P. [1 ]
Titt, U. [1 ]
Mohan, R. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.2761112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of stereotactic radiation therapy for lung cancer using photon beams from an accelerator operated without a flattening filter. To determine potential benefits and drawback of using unflattened beams for this type of treatment. Methods and Materials: Treatment plans were generated for 10 lung cancer patients with small, less than 3 cm diameter, isolated lesions using a dose prescription of 12.5 Gy/fx, the standard for these treatments in our clinic. Plans were generated with Eclipse 8.0 (Varian Medical Systems) commissioned with beam data measured on a Clinac 21EX (Varian Medical Systems) operated with and without the flattening filter. For each patient two plans were generated, one with and one without the flattening filter. All patients were forward planned using wedges and/or static multuleaf collimator with one or two segments per field. Results: Removal of the flattening filter increased the dose rate. For 6 MV beams the total beam‐on time per plan was lower by a factor of 2.31±0.02 in plans with unflattened beams. The median beam‐on time per field was reduced from 37s with the filter to 15s without one, suggesting the feasibility of breath‐hold treatments with unflattened beams for a majority of patients. These comparisons were made assuming the same current of electrons incident on the bremsstrahlung target. The median difference between maximum and minimum doses in the planning target volume divided by the mean target dose was 0.21 with, and 0.22 without the filter. Differences in doses to organs at risk were within approximately ±10 cGy without significant advantage of one modality over another. Conclusion: Dose distributions in treatment plans with unflattened beam were close to those achieved with flattened beams, but required substantially lower beam‐on time, increasing the feasibility of breath‐hold gated treatments. Conflict of Interest: Research is sponsored by Varian Medical Systems. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2491 / 2491
页数:1
相关论文
共 50 条
  • [1] Stereotactic radiotherapy for lung cancer using a flattening filter free Clinac
    Vassiliev, Oleg N.
    Kry, Stephen F.
    Chang, Joe Y.
    Balter, Peter A.
    Titt, Uwe
    Mohan, Radhe
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (01): : 14 - 21
  • [2] Dosimetric Study of Stereotactic Body Radiotherapy Using Flattening Filter Free Beams for Peripheral Lung Cancer
    Deng, C.
    Zhang, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [3] Clinical outcomes of stereotactic radiotherapy using flattening-filter-free in lung cancers
    Taweesakulvashra, T.
    Kitpanit, S.
    Songthong, A.
    Chakkabat, C.
    Amornwichet, N.
    Alisanant, P.
    Nantavithya, C.
    Lertbutsayanukul, C.
    Shotelersuk, K.
    Khorprasert, C.
    Kannarunimit, D.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S733 - S734
  • [4] Stereotactic body radiotherapy for early-stage lung cancer with flattening filter free beams
    Zhang, J.
    Peng, X.
    Hong, D.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S780 - S781
  • [5] Optimization of leaf margins for lung stereotactic body radiotherapy using a flattening filter-free beam
    Wakai, Nobuhide
    Sumida, Iori
    Otani, Yuki
    Suzuki, Osamu
    Seo, Yuji
    Isohashi, Fumiaki
    Yoshioka, Yasuo
    Hasegawa, Masatoshi
    Ogawa, Kazuhiko
    MEDICAL PHYSICS, 2015, 42 (05) : 2125 - 2131
  • [6] Optimizing the flattening filter free beam selection in RapidArc®-based stereotactic body radiotherapy for Stage I lung cancer
    Lu, J-Y
    Lin, Z.
    Lin, P-X
    Huang, B-T
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1053):
  • [7] Comparison of Two RapidArc Delivery Strategies in Stereotactic Body Radiotherapy of Peripheral Lung Cancer with Flattening Filter Free Beams
    Huang, Bao-Tian
    Lu, Jia-Yang
    Lin, Pei-Xian
    Chen, Jian-Zhou
    Kuang, Yu
    Chen, Chuang-Zhen
    PLOS ONE, 2015, 10 (07):
  • [8] Improved clinical efficiency in CNS stereotactic radiosurgery using a flattening filter free linear accelerator
    Prendergast, Brendan M.
    Popple, Richard A.
    Clark, Grant M.
    Spencer, Sharon A.
    Guthrie, Bart
    Markert, James
    Fiveash, John B.
    JOURNAL OF RADIOSURGERY AND SBRT, 2011, 1 (02): : 117 - 122
  • [9] Clinical application of flattening filter free beams for extracranial stereotactic radiotherapy
    Lang
    Shrestha, B.
    Graydon, S.
    Cavelaars, F.
    Linsenmeier, C.
    Studer, G.
    Riesterer, O.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 743 - 743
  • [10] Flattening filter-free technique in volumetric modulated arc therapy for lung stereotactic body radiotherapy: A clinical comparison with the flattening filter technique
    Aoki, Shuri
    Yamashita, Hideomi
    Haga, Akihiro
    Nawa, Kanabu
    Imae, Toshikazu
    Takahashi, Wataru
    Abe, Osamu
    Nakagawa, Keiichi
    ONCOLOGY LETTERS, 2018, 15 (03) : 3928 - 3936